文献速递脑血管病

急性卒中灌注磁共振成像半暗带检测:15O-PET验证

Penumbra detection in acute stroke with perfusion magnetic resonance imaging: Validation with 15 O-positron emission tomography.
PubMed 文献 · Ann Neurol · 2019-04-22

结果显示Tmax图检测半暗带表现最佳(AUC=0.88),Tmax>5.6秒阈值的敏感性和特异性均>80%,可用于指导发病48小时内的治疗决策。

要点

  • Tmax图检测半暗带表现最佳,AUC=0.88。
  • Tmax>5.6秒区分半暗带与乏血流的敏感性和特异性均>80%。
  • Tmax>5.6秒半暗带检测在发病48小时内可靠指导治疗决策。

核心结论

  • 最佳灌注加权指标Tmax检测缺血性卒中上半暗带血流阈值的表现优秀。
  • 基于Tmax>5.6秒的半暗带检测在发病48小时内可可靠指导治疗决策,可能有助于扩展再灌注治疗时间窗。

研究设计与样本

  • 以15O-PET的脑血流量、氧摄取分数和氧代谢定义的半暗带验证多种灌注加权指标,采用基于体素的受试者工作特征曲线分析。
  • B组23例患者在发病48小时内以定量15O-PET脑血流量定义的半暗带进行同样验证以作比较。

主要发现

  • 灌注加权图Tmax在检测发病48小时内半暗带组织方面表现最佳,曲线下面积为0.88。
  • 区分半暗带与乏血流的最佳阈值为Tmax>5.6秒,敏感性和特异性均>80%。

关键数值与推荐

  • Tmax>5.6秒为区分半暗带与乏血流的最佳阈值,敏感性和特异性均>80%。
  • Tmax图检测半暗带的曲线下面积为0.88。

临床怎么用

  • Tmax>5.6秒的半暗带检测可用于发病48小时内指导治疗决策。
  • 该检测可能有助于将再灌注治疗扩展至当前时间窗之外。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Accurate identification of the ischemic penumbra, the therapeutic target in acute clinical stroke, is of critical importance to identify patients who might benefit from reperfusion therapies beyond the established time windows. Therefore, we aimed to validate magnetic resonance imaging (MRI) mismatch-based penumbra detection against full quantitative positron emission tomography (15 O-PET), the gold standard for penumbra detection in acute ischemic stroke. METHODS: Ten patients (group A) with acute and subacute ischemic stroke underwent perfusion-weighted (PW)/diffusion-weighted MRI and consecutive full quantitative 15 O-PET within 48 hours of stroke onset. Penumbra as defined by 15 O-PET cerebral blood flow (CBF), oxygen extraction fraction, and oxygen metabolism was used to validate a wide range of established PW measures (eg, time-to-maximum [Tmax]) to optimize penumbral tissue detection. Validation was carried out using a voxel-based receiver-operating-characteristic curve analysis. The same validation based on penumbra as defined by quantitative 15 O-PET CBF was performed for comparative reasons in 23 patients measured within 48 hours of stroke onset (group B). RESULTS: The PW map Tmax (area-under-the-curve = 0.88) performed best in detecting penumbral tissue up to 48 hours after stroke onset. The optimal threshold to discriminate penumbra from oligemia was Tmax >5.6 seconds with a sensitivity and specificity of >80%. INTERPRETATION: The performance of the best PW measure Tmax to detect the upper penumbral flow threshold in ischemic stroke is excellent. Tmax >5.6 seconds-based penumbra detection is reliable to guide treatment decisions up to 48 hours after stroke onset and might help to expand reperfusion treatment beyond the current time windows. ANN NEUROL 2019;85:875-886.

来源:Ann Neurol,查看原文。版权归原作者所有。

引用

  1. Zaro-Weber O, Fleischer H, Reiblich L, et al. Penumbra detection in acute stroke with perfusion magnetic resonance imaging: Validation with 15 O-positron emission tomography. Ann Neurol. 2019. PMID: 30937950. doi:10.1002/ana.25479

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。