文献速递帕金森病与运动障碍

丘脑Vim脑深部电刺激治疗特发性震颤的长期疗效:观察者盲法研究

Long-term efficacy of deep brain stimulation for essential tremor: An observer-blinded study.
PubMed 文献 · Neurology · 2019-02-20

该观察者盲法研究纳入20例药物难治性重度特发性震颤患者,在术后短期(13.1±1.9个月)和长期(32至120个月,平均71.9±6.9个月)评估Vim-DBS的疗效。结果显示短期和长期刺激均显著改善震颤评分,但刺激效应与术后时间呈负相关(ρ=-0.78,p<0.001),提示长期疗效减退。

要点

  • Vim-DBS在短期和长期均显著改善特发性震颤的震颤评分。
  • 刺激效应与术后时间呈负相关(ρ=-0.78,p<0.001),长期疗效减退。
  • 仅三分之一患者关机后出现1小时内终止的反跳效应。

核心结论

  • Vim-DBS对药物难治性重度特发性震颤的疗效随术后时间延长而显著减退。
  • 长期随访中,刺激状态下震颤评分的恶化比非刺激状态更明显,提示对刺激的适应。

研究设计与样本

  • 观察者盲法研究,纳入20例接受Vim-DBS的特发性震颤患者。
  • 在基线、术后短期(13.1±1.9个月)及长期(32至120个月,平均71.9±6.9个月)进行标准化视频记录评估。
  • 主要结局为由2名运动障碍神经科医生盲法评估的震颤评定量表(TRS)。

主要发现

  • 短期和长期Vim-DBS均显著改善TRS,螺旋评分和功能指标也显示类似改善,所有变化均高度显著。
  • 刺激效应与术后时间呈负相关(ρ=-0.78,p<0.001),次要结局也显示相同趋势。
  • 仅三分之一患者在关机后出现反跳效应,并在60分钟内终止。
  • 长期TRS恶化在刺激开启状态下比刺激关闭状态更严重,提示对刺激的适应。

关键数值与推荐

  • 刺激效应与术后时间的相关系数ρ=-0.78,p<0.001。
  • 反跳效应在关机后60分钟内终止的患者占三分之一。

临床怎么用

  • Vim-DBS治疗特发性震颤需考虑长期疗效减退,应定期评估震颤控制情况。
  • 对于疗效减退的患者,可能需要调整刺激参数或考虑其他治疗策略。

局限性

  • 样本量较小(20例)。
  • 证据等级为Class IV。
  • 长期随访时间范围较宽(32至120个月)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Deep brain stimulation (DBS) of the ventral intermediate thalamic nucleus (Vim) is established for medically refractory severe essential tremor (ET), but long-term efficacy is controversial. METHODS: Twenty patients with ET with DBS had standardized video-documented examinations at baseline, in the stimulation-on condition at short term (13.1 ± 1.9 months since surgery, mean ± SEM), and in the stimulator switched on and off (stim-ON/OFF) at long term; all assessments were done between 32 and 120 months (71.9 ± 6.9 months) after implantation. The primary outcome was the Tremor Rating Scale (TRS) blindly assessed by 2 trained movement disorder neurologists. Secondary outcomes were TRS subscores A, B, and C; Archimedes spiral score; and activities of daily living score. At long-term follow-up, tremor was additionally recorded with accelerometry. The rebound effect after switching the stimulator off was assessed for 1 hour in a subgroup. RESULTS: Tremor severity worsened considerably over time in both in the nonstimulated and stimulated conditions. Vim-DBS improved the TRS in the short term and long term significantly. The spiral score and functional measures showed similar improvements. All changes were highly significant. However, the stimulation effect was negatively correlated with time since surgery (ρ = -0.78, p < 0.001). This was also true for the secondary outcomes. Only one-third of the patients had a rebound effect terminated 60 minutes after the stimulator was switched off. Long-term worsening of the TRS was more profound during stim-ON than in the stim-OFF condition, indicating habituation to stimulation. CONCLUSION: Vim-DBS loses efficacy over the long term. Efforts are needed to improve the long-term efficacy of Vim-DBS. CLASSIFICATION OF EVIDENCE: This study provides Class IV evidence that for patients with medically refractory severe ET, the efficacy of Vim-DBS severely decreases over 10 years.

来源:Neurology,查看原文。版权归原作者所有。

引用

  1. Paschen S, Forstenpointner J, Becktepe J, et al. Long-term efficacy of deep brain stimulation for essential tremor: An observer-blinded study. Neurology. 2019. PMID: 30787161. doi:10.1212/WNL.0000000000007134

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。