文献速递癫痫

电磁源成像在癫痫术前评估中的前瞻性研究

Electromagnetic source imaging in presurgical workup of patients with epilepsy: A prospective study.
PubMed 文献 · Neurology · 2019-01-04

该前瞻性研究纳入141例连续癫痫患者,在术前评估中同步记录脑磁图与脑电图并进行电磁源成像。电磁源成像在67%患者中定位癫痫样放电,改变了34%患者的管理方案,且80%的改变有用。其定位准确性与MRI和PET无显著差异。

要点

  • 电磁源成像在67%的癫痫患者中定位了癫痫样放电。
  • 电磁源成像改变了34%患者的管理方案,其中80%有用。
  • 电磁源成像定位准确性与MRI和PET无显著差异。

核心结论

  • 电磁源成像的定位准确性与现有影像方法相似,并在34%的患者中提供了有临床用处的新信息。

研究设计与样本

  • 前瞻性研究,连续纳入141例癫痫患者,同步记录脑磁图与脑电图并进行电磁源成像,以颅内记录和术后1年结局为参考标准。

主要发现

  • 电磁源成像在94例(67%)患者中显示定位的癫痫样放电。
  • 大多数癫痫样放电簇(72%)被两种模态共同识别,15%仅由脑电图识别,14%仅由脑磁图识别。
  • 电磁源成像改变了34%患者的管理方案,这些改变在80%中是有用的。
  • 电磁源成像与致痫刺激区的一致性为53%至89%,与发作起始区的一致性为35%至73%,取决于方法。
  • 电磁源成像的定位准确性为44%至57%,与MRI(49%-76%)和PET(54%-85%)无显著差异。

关键数值与推荐

  • 电磁源成像与致痫刺激区的一致性为53%至89%,与发作起始区的一致性为35%至73%,取决于分析方式。

临床怎么用

  • 电磁源成像可作为癫痫术前评估的辅助工具,提供与现有影像方法相似的定位准确性,并可能改变临床管理。

局限性

  • 本研究提供IV级证据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To determine the diagnostic accuracy and clinical utility of electromagnetic source imaging (EMSI) in presurgical evaluation of patients with epilepsy. METHODS: We prospectively recorded magnetoencephalography (MEG) simultaneously with EEG and performed EMSI, comprising electric source imaging, magnetic source imaging, and analysis of combined MEG-EEG datasets, using 2 different software packages. As reference standard for irritative zone (IZ) and seizure onset zone (SOZ), we used intracranial recordings and for localization accuracy, outcome 1 year after operation. RESULTS: We included 141 consecutive patients. EMSI showed localized epileptiform discharges in 94 patients (67%). Most of the epileptiform discharge clusters (72%) were identified by both modalities, 15% only by EEG, and 14% only by MEG. Agreement was substantial between inverse solutions and moderate between software packages. EMSI provided new information that changed the management plan in 34% of the patients, and these changes were useful in 80%. Depending on the method, EMSI had a concordance of 53% to 89% with IZ and 35% to 73% with SOZ. Localization accuracy of EMSI was between 44% and 57%, which was not significantly different from MRI (49%-76%) and PET (54%-85%). Combined EMSI achieved significantly higher odds ratio compared to electric source imaging and magnetic source imaging. CONCLUSION: EMSI has accuracy similar to established imaging methods and provides clinically useful, new information in 34% of the patients. CLASSIFICATION OF EVIDENCE: This study provides Class IV evidence that EMSI had a concordance of 53%-89% and 35%-73% (depending on analysis) for the localization of epileptic focus as compared with intracranial recordings-IZ and SOZ, respectively.