文献速递神经肌肉病

神经超声:周围神经病可重复的诊断工具

Nerve ultrasound: A reproducible diagnostic tool in peripheral neuropathy.
PubMed 文献 · Neurology · 2019-01-28

这项前瞻性多中心研究纳入20例慢性获得性脱髓鞘或轴索性多神经病患者和10名健康对照,评估神经超声的观察者间变异。结果显示不同检查者间测量差异小,手臂神经的组内相关系数高于腿部神经,医院中心和超声设备类型不影响观察者间变异。

要点

  • 神经超声在周围神经病中观察者间变异总体有限,尤其手臂神经。
  • 不同超声设备和多中心设置不影响观察者间变异。
  • 神经超声可作为常规临床实践和多中心研究的可重复诊断工具。

核心结论

  • 神经超声在周围神经病中的观察者间变异总体有限,尤其在手臂神经,且不同设备和多中心设置无显著影响,因此是常规临床和多中心研究的可重复工具。

研究设计与样本

  • 前瞻性、系统性、多中心研究纳入20例慢性获得性脱髓鞘或轴索性多神经病患者和10名健康对照,在3个中心进行广泛神经超声协议检查。

主要发现

  • 不同检查者间测量的系统差异小,平均差异0.11 mm²(95%CI 0.00-0.23 mm²)。
  • 组内相关系数手臂神经为0.48-0.96,腿部神经为0.46-0.61。
  • 随机效应模型显示医院中心和超声设备对观察者间变异无显著贡献。

临床怎么用

  • 神经超声可用于周围神经病的常规诊断和多中心研究,手臂神经测量重复性更佳。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To determine interobserver variability of nerve ultrasound in peripheral neuropathy in a prospective, systematic, multicenter study. METHODS: We enrolled 20 patients with an acquired chronic demyelinating or axonal polyneuropathy and 10 healthy controls in 3 different centers. All participants underwent an extensive nerve ultrasound protocol, including cross-sectional area measurements of median, ulnar, fibular, tibial, and sural nerves, and brachial plexus. Real-time image acquisition was performed blind by a local and a visiting investigator (reference). Five patients were investigated using different types of sonographic devices. Intraclass correlation coefficients were calculated, and a random-effects model was fitted to identify factors with significant effect on interobserver variability. RESULTS: Systematic differences between measurements made by different investigators were small (mean difference 0.11 mm2 [95% confidence interval 0.00-0.23 mm2]). Intraclass correlation coefficients were generally higher in arm nerves (0.48-0.96) than leg nerves (0.46-0.61). The hospital site and sonographic device did not contribute significantly to interobserver variability in the random-effects model. CONCLUSIONS: Interobserver variability of nerve ultrasound in peripheral neuropathy is generally limited, especially in arm nerves. Different devices and a multicenter setting have no effect on interobserver variability. Therefore, nerve ultrasound is a reproducible tool for diagnostics in routine clinical practice and (multicenter) research.

来源:Neurology,查看原文。版权归原作者所有。

引用

  1. Telleman JA, Herraets IJT, Goedee HS, et al. Nerve ultrasound: A reproducible diagnostic tool in peripheral neuropathy. Neurology. 2019. PMID: 30593519. doi:10.1212/WNL.0000000000006856

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。