7T MRI显示小血管病相关卒中患者穿支动脉搏动性增高
该探索性研究采用7T二维相位对比MRI测量脑穿支动脉血流速度,比较10例腔隙性梗死、11例深部脑出血患者与18例年龄性别匹配健康对照。结果显示患者基底节和半卵圆中心穿支动脉检出数减少、搏动指数升高,提示小血管病可直接表现为小血管功能指标异常。
要点
- 7T MRI可无创评估穿支动脉搏动指数等功能指标
- 小血管病相关卒中患者穿支动脉搏动指数高于健康对照
- 患者穿支动脉检出数目少于对照,提示功能异常
核心结论
- 小血管病可通过直接源于小血管自身的功能指标如搏动指数来表达。
研究设计与样本
- 探索性研究纳入10例腔隙性梗死患者(平均61岁,80%男性)、11例考虑由小血管病所致的深部脑出血患者(平均58岁,82%男性)和18例年龄性别匹配健康对照。
- 采用7T二维相位对比MRI测量半卵圆中心和基底节穿支动脉的时间分辨血流速度。
主要发现
- 基底节检出穿支数:腔隙性梗死26±9(P=0.01)、深部脑出血28±6(P=0.02)均低于对照35±7。
- 基底节搏动指数:腔隙性梗死1.07±0.13(P=0.03)、深部脑出血1.02±0.11(P=0.11)高于对照0.94±0.10。
- 半卵圆中心检出穿支数:腔隙性梗死32±18(P=0.06)、深部脑出血28±18(P=0.02)低于对照45±16。
- 半卵圆中心搏动指数:腔隙性梗死1.18±0.15(P=0.02)、深部脑出血1.17±0.14(P=0.045)高于对照1.08±0.07。
- 未检测到血流速度差异。
临床怎么用
- 该技术尚处探索阶段,暂不能用于临床常规评估小血管病。
局限性
- 探索性研究样本量小,结果需更大规模研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Background and Purpose- Cerebral small vessel disease (SVD) is a major cause of stroke and dementia, but underlying disease mechanisms are still largely unknown, partly because of the difficulty in assessing small vessel function in vivo. We developed a method to measure blood flow velocity pulsatility in perforating arteries in the basal ganglia and semioval center. We aimed to determine whether this novel method could detect functional abnormalities at the level of the small vessels in patients with stroke attributable to SVD. Methods- We investigated 10 patients with lacunar infarction (mean age 61 years, 80% men), 11 patients with deep intracerebral hemorrhage (ICH) considered to be caused by SVD (ICH, mean age 58 years, 82% men) and 18 healthy controls that were age- and sex-matched. We performed 2-dimensional phase contrast magnetic resonance imaging at 7 T to measure time-resolved blood flow velocity in cerebral perforating arteries of the semioval center and the basal ganglia. We compared the number of detected arteries, pulsatility index and mean velocity between the patient groups and controls. Results- In the basal ganglia, the number of detected perforators was lower in lacunar infarction (26±9, P=0.01) and deep ICH patients (28±6, P=0.02) than in controls (35±7). The pulsatility index in the basal ganglia was higher in lacunar infarction (1.07±0.13, P=0.03), and deep ICH patients (1.02±0.11, P=0.11), than in controls (0.94±0.10). Observations in the semioval center were similar. Number of detected perforators was lower in lacunar infarction (32±18, P=0.06), and deep ICH patients (28±18, P=0.02), than in controls (45±16). The pulsatility index was higher in lacunar infarction (1.18±0.15, P=0.02), and deep ICH patients (1.17±0.14, P=0.045) than in controls (1.08±0.07). No velocity differences were detected. Conclusions- This exploratory study shows that SVD can be expressed in terms of functional measures, such as pulsatility index, which are derived directly from the small vessels themselves. Future studies may use this technique to further unravel the mechanisms underlying SVD.
引用
- Geurts LJ, Zwanenburg JJM, Klijn CJM, et al. Higher Pulsatility in Cerebral Perforating Arteries in Patients With Small Vessel Disease Related Stroke, a 7T MRI Study. Stroke. 2018. PMID: 30580730. doi:10.1161/STROKEAHA.118.022516
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。