3T MRI未能改善多发性硬化的诊断:一项多中心研究
该多中心研究纳入66例临床孤立综合征患者和26名健康对照,比较1.5T与3T脑和脊髓MRI。3T较1.5T多检出15%的T2脑病灶,但未提高满足2017年McDonald诊断标准中空间多发或时间多发或后续多发性硬化诊断的患者数量。
要点
- 3T较1.5T多检出15%的T2脑病灶,主要来自脑室旁、近皮质和深部白质病灶。
- 脊髓病灶和钆增强病灶的检出率在两种场强间无差异。
- 3T未增加满足空间多发、时间多发或后续多发性硬化诊断的患者数。
核心结论
- 3T扫描不影响根据McDonald诊断标准作出的多发性硬化诊断。
研究设计与样本
- 多中心研究,在6个多发性硬化中心招募66例症状出现6个月内的临床孤立综合征患者和26名健康对照。
- 所有参与者在基线接受1.5T和3T脑及脊髓MRI,随访期间未转为多发性硬化的患者接受3-6个月和12-15个月的重复脑MRI。
- 由3名评估者共识评分各解剖区域的病灶数量,并根据2017年修订的McDonald标准判定空间多发和时间多发。
主要发现
- 3T较1.5T多检出15%的T2脑病灶(p < 0.001)。
- 3T较1.5T多检出脑室旁病灶12%(p = 0.015)、(近)皮质病灶21%(p = 0.005)和深部白质病灶21%(p < 0.001)。
- 脊髓病灶和钆增强病灶的检出率在两种场强间无差异。
- 3T未导致在3个时间点中任一时间点满足空间多发或时间多发标准或后续多发性硬化诊断的患者数量增加。
关键数值与推荐
- 空间多发和时间多发根据2017年修订的McDonald标准判定。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: In the work-up of patients presenting with a clinically isolated syndrome (CIS), 3T MRI might offer a higher lesion detection than 1.5T, but it remains unclear whether this affects the fulfilment of the diagnostic criteria for multiple sclerosis (MS). METHODS: We recruited 66 patients with CIS within 6 months from symptom onset and 26 healthy controls in 6 MS centers. All participants underwent 1.5T and 3T brain and spinal cord MRI at baseline according to local optimized protocols and the MAGNIMS guidelines. Patients who had not converted to MS during follow-up received repeat brain MRI at 3-6 months and 12-15 months. The number of lesions per anatomical region was scored by 3 raters in consensus. Criteria for dissemination in space (DIS) and dissemination in time (DIT) were determined according to the 2017 revisions of the McDonald criteria. RESULTS: Three-Tesla MRI detected 15% more T2 brain lesions compared to 1.5T (p < 0.001), which was driven by an increase in baseline detection of periventricular (12%, p = 0.015), (juxta)cortical (21%, p = 0.005), and deep white matter lesions (21%, p < 0.001). The detection rate of spinal cord lesions and gadolinium-enhancing lesions did not differ between field strengths. Three-Tesla MRI did not lead to a higher number of patients fulfilling the criteria for DIS or DIT, or subsequent diagnosis of MS, at any of the 3 time points. CONCLUSION: Scanning at 3T does not influence the diagnosis of MS according to McDonald diagnostic criteria.
引用
- Hagens MHJ, Burggraaff J, Kilsdonk ID, et al. Three-Tesla MRI does not improve the diagnosis of multiple sclerosis: A multicenter study. Neurology. 2018. PMID: 29925550. doi:10.1212/WNL.0000000000005825
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。