文献速递脑血管病认知障碍与痴呆

英国生物银行白质完整性遗传研究(N=8448)及其与卒中、抑郁和痴呆的重叠

Genetic Study of White Matter Integrity in UK Biobank (N=8448) and the Overlap With Stroke, Depression, and Dementia.
PubMed 文献 · Stroke · 2018-05-11

基于英国生物银行8448名40至69岁个体的全基因组关联分析,发现VCAN基因新位点与白质微结构完整性(FA和MD)相关,FA、MD和WMHV与腔隙性卒中相关,MD与重性抑郁障碍相关,WMHV与阿尔茨海默病相关。

要点

  • VCAN基因位点rs13164785与MD相关(P=3.7×10-18),rs67827860与FA相关(P=1.3×10-14)。
  • FA、MD和WMHV在全基因组水平显著相关(FA-WMHV rG 0.39,MD-WMHV rG 0.56)。
  • 多基因风险评分分析中,FA、MD和WMHV与腔隙性卒中显著相关,MD与重性抑郁障碍相关,WMHV与阿尔茨海默病相关。

核心结论

  • VCAN基因内的遗传变异可能在FA和MD所测脑白质微结构完整性的机制中发挥作用。
  • 白质改变的机制与脑血管病共享,白质微结构的遗传差异影响阿尔茨海默病和重性抑郁障碍。

研究设计与样本

  • 全基因组关联分析,纳入英国生物银行8448名个体,该人群为基础队列于2006年至2010年间在英国各地招募40至69岁个体。
  • 微结构完整性用弥散张量成像的FA和MD衍生参数测量,WMHV在T2加权FLAIR图像上评估。

主要发现

  • 发现1个全基因组显著的新位点:VCAN基因rs13164785与MD相关(P=3.7×10-18),rs67827860与FA相关(P=1.3×10-14)。
  • LD score回归显示FA、MD与WMHV之间存在显著的全基因组相关性:FA-WMHV rG 0.39(SE,0.15),MD-WMHV rG 0.56(SE,0.19)。
  • 多基因风险评分分析中,FA、MD和WMHV与腔隙性卒中显著相关,MD与重性抑郁障碍相关,WMHV与阿尔茨海默病相关。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: Structural integrity of the white matter is a marker of cerebral small vessel disease, which is the major cause of vascular dementia and a quarter of all strokes. Genetic studies provide a way to obtain novel insights in the disease mechanism underlying cerebral small vessel disease. The aim was to identify common variants associated with microstructural integrity of the white matter and to elucidate the relationships of white matter structural integrity with stroke, major depressive disorder, and Alzheimer disease. METHODS: This genome-wide association analysis included 8448 individuals from UK Biobank-a population-based cohort study that recruited individuals from across the United Kingdom between 2006 and 2010, aged 40 to 69 years. Microstructural integrity was measured as fractional anisotropy- (FA) and mean diffusivity (MD)-derived parameters on diffusion tensor images. White matter hyperintensity volumes (WMHV) were assessed on T2-weighted fluid-attenuated inversion recovery images. RESULTS: We identified 1 novel locus at genome-wide significance (VCAN [versican]: rs13164785; P=3.7×10-18 for MD and rs67827860; P=1.3×10-14 for FA). LD score regression showed a significant genome-wide correlation between FA, MD, and WMHV (FA-WMHV rG 0.39 [SE, 0.15]; MD-WMHV rG 0.56 [SE, 0.19]). In polygenic risk score analysis, FA, MD, and WMHV were significantly associated with lacunar stroke, MD with major depressive disorder, and WMHV with Alzheimer disease. CONCLUSIONS: Genetic variants within the VCAN gene may play a role in the mechanisms underlying microstructural integrity of the white matter in the brain measured as FA and MD. Mechanisms underlying white matter alterations are shared with cerebrovascular disease, and inherited differences in white matter microstructure impact on Alzheimer disease and major depressive disorder.

来源:Stroke,查看原文。版权归原作者所有。

引用

  1. Rutten-Jacobs LCA, Tozer DJ, Duering M, et al. Genetic Study of White Matter Integrity in UK Biobank (N=8448) and the Overlap With Stroke, Depression, and Dementia. Stroke. 2018. PMID: 29752348. doi:10.1161/STROKEAHA.118.020811

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。