文献速递脑血管病

校正延迟与离散效应可提高急性卒中患者脑血流量缺血核心测量的准确性

Correction for Delay and Dispersion Results in More Accurate Cerebral Blood Flow Ischemic Core Measurement in Acute Stroke.
PubMed 文献 · Stroke · 2018-03-02

本研究纳入55例发病6小时内行灌注CT的缺血性卒中患者,比较标准脑血流量与校正延迟和离散效应后的脑血流量所测缺血核心体积。校正后缺血核心体积更接近弥散加权成像参考标准,且对良好临床结局的预测能力更高。

要点

  • 校正延迟和离散效应后,缺血核心体积中位数由38.5 mL降至17.2 mL。
  • 校正后缺血核心与弥散加权成像参考的平均体积差为-0.1 mL,标准测量为16.7 mL。
  • 校正后定义的有利影像模式对良好临床结局的比值比为7.8。

核心结论

  • 校正延迟和离散效应可提高灌注CT对缺血核心测量的准确性。

研究设计与样本

  • 纳入发病6小时内完成灌注CT的缺血性卒中患者55例,对灌注CT数据分别处理生成标准脑血流量和校正延迟与离散效应的脑血流量,以相对阈值小于正常组织的30%测量缺血核心。

主要发现

  • 标准脑血流量所测缺血核心体积中位数为38.5 mL(12.4-61.9 mL),大于校正后脑血流量所测的17.2 mL(四分位距5.5-38.8;P<0.001)。
  • 校正后脑血流量小于30%所测缺血核心与弥散加权成像参考的平均体积差为-0.1 mL(95%一致性界限-25.4至25.2;P=0.97),标准脑血流量小于30%的平均体积差为16.7 mL(95%一致性界限-21.7至55.2;P<0.001)。
  • 标准脑血流量与校正后脑血流量定义的影像模式存在差异(P<0.001),12例患者被校正后脑血流量归为有利影像模式而被标准脑血流量归为不利影像模式。
  • 校正后脑血流量定义的有利影像模式对良好临床结局的预测比值比为7.8(2-30.5),标准脑血流量为3.1(0.9-11)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: This study aimed to assess how the ischemic core measured by perfusion computed tomography (CTP) was affected by the delay and dispersion effect. METHODS: Ischemic stroke patients having CTP performed within 6 hours of onset were included. The CTP data were processed twice, generating standard cerebral blood flow (sCBF) and delay- and dispersion-corrected CBF (ddCBF), respectively. Ischemic core measured by the sCBF and ddCBF was then compared at the relative threshold <30% of normal tissue. Two references for ischemic core were used: acute diffusion-weighted imaging or 24-hour diffusion-weighted imaging in patients with complete recanalization. Difference of core volume between CTP and diffusion-weighted imaging was estimated by Mann-Whitney U test and limits of agreement. Patients were also classified into favorable and unfavorable CTP patterns. The imaging pattern classification by sCBF and ddCBF was compared by the χ2 test; their respective ability to predict good clinical outcome (3-month modified Rankin Scale score) was tested in logistic regression. RESULTS: Fifty-five patients were included in this study. Median sCBF ischemic core volume was 38.5 mL (12.4-61.9 mL), much larger than the median core volume of 17.2 mL measured by ddCBF (interquartile range, 5.5-38.8; P<0.001). Moreover, compared with sCBF <30%, ddCBF <30% measured the ischemic core much closer to diffusion-weighted imaging core references, with the mean volume difference of -0.1 mL (95% limits of agreement, -25.4 to 25.2; P=0.97) and 16.7 mL (95% limits of agreement, -21.7 to 55.2; P<0.001), respectively. Imaging patterns defined by sCBF showed a difference to that defined by ddCBF (P<0.001), with 12 patients classified as favorable imaging patterns by ddCBF but as unfavorable by sCBF. The favorable imaging pattern classified by ddCBF, compared with sCBF classification, had higher predictive power for good clinical outcome (odds ratio, 7.8 [2-30.5] and 3.1 [0.9-11], respectively). CONCLUSIONS: Delay and dispersion correction increases the accuracy of ischemic core measurement on CTP.

来源:Stroke,查看原文。版权归原作者所有。

引用

  1. Lin L, Bivard A, Kleinig T, et al. Correction for Delay and Dispersion Results in More Accurate Cerebral Blood Flow Ischemic Core Measurement in Acute Stroke. Stroke. 2018. PMID: 29500248. doi:10.1161/STROKEAHA.117.019562

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。