洛杉矶运动量表识别大血管闭塞:院前验证及与其他筛查工具的比较
本研究在94例疑似卒中转运患者中,由急救员院前应用洛杉矶运动量表(LAMS),评估其识别急性脑缺血所致大血管闭塞(LVO)及适合综合卒中中心(CSC)收治患者(LVO急性脑缺血及颅内出血)的表现,并与到院后同时实施的6种其他量表及完整美国国立卫生研究院卒中量表进行比较。LAMS院前识别LVO的C统计量为0.79、准确率0.72,识别CSC适合患者的C统计量为0.80、准确率0.72;到院后LAMS准确率与7种对照量表相当或更优。
要点
- 急救员院前应用LAMS识别LVO的C统计量为0.79、准确率0.72。
- LAMS识别CSC适合患者的C统计量为0.80、准确率0.72。
- 到院后LAMS对LVO准确率0.70,其他量表为0.62至0.68。
核心结论
- 急救员院前实施的LAMS能以良好准确率识别LVO和CSC适合患者。
- LAMS表现与更扩展的院前量表及完整美国国立卫生研究院卒中量表相当或更优。
研究设计与样本
- 研究纳入连续救护车试验患者,由急救员院前实施LAMS,共94例,年龄70(±13)岁,女性49%。
- 评估LAMS在全部急性脑缺血患者中识别LVO、在全部疑似卒中中识别CSC适合患者的表现。
- 到院后将LAMS与6种拟用于急救员的量表和完整美国国立卫生研究院卒中量表同时比较。
主要发现
- 最终诊断:急性脑缺血76%(其中LVO 48%、非LVO 28%),颅内出血19%,神经血管模拟症5%。
- 院前LAMS识别LVO的C统计量为0.79、准确率0.72。
- 院前LAMS识别CSC适合患者的C统计量为0.80、准确率0.72。
- 到院后LAMS识别LVO的准确率为0.70,其他量表为0.62至0.68。
- 到院后LAMS识别CSC适合患者的准确率为0.73,其他量表为0.56至0.73。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND PURPOSE: Prehospital scales have been developed to identify patients with acute cerebral ischemia (ACI) because of large vessel occlusion (LVO) for direct routing to Comprehensive Stroke Centers (CSCs), but few have been validated in the prehospital setting, and their impact on routing of patients with intracranial hemorrhage has not been delineated. The purpose of this study was to validate the Los Angeles Motor Scale (LAMS) for LVO and CSC-appropriate (LVO ACI and intracranial hemorrhage patients) recognition and compare the LAMS to other scales. METHODS: The performance of the LAMS, administered prehospital by paramedics to consecutive ambulance trial patients, was assessed in identifying (1) LVOs among all patients with ACI and (2) CSC-appropriate patients among all suspected strokes. Additionally, the LAMS administered postarrival was compared concurrently with 6 other scales proposed for paramedic use and the full National Institutes of Health Stroke Scale. RESULTS: Among 94 patients, age was 70 (±13) and 49% female. Final diagnoses were ACI in 76% (because of LVO in 48% and non-LVO in 28%), intracranial hemorrhage in 19%, and neurovascular mimic in 5%. The LAMS administered by paramedics in the field performed moderately well in identifying LVO among patients with ACI (C statistic, 0.79; accuracy, 0.72) and CSC-appropriate among all suspected stroke transports (C statistic, 0.80; accuracy, 0.72). When concurrently performed in the emergency department postarrival, the LAMS showed comparable or better accuracy versus the 7 comparator scales, for LVO among ACI (accuracies LAMS, 0.70; other scales, 0.62-0.68) and CSC-appropriate (accuracies LAMS, 0.73; other scales, 0.56-0.73). CONCLUSIONS: The LAMS performed in the field by paramedics identifies LVO and CSC-appropriate patients with good accuracy. The LAMS performs comparably or better than more extended prehospital scales and the full National Institutes of Health Stroke Scale.
引用
- Noorian AR, Sanossian N, Shkirkova K, et al. Los Angeles Motor Scale to Identify Large Vessel Occlusion: Prehospital Validation and Comparison With Other Screens. Stroke. 2018. PMID: 29459391. doi:10.1161/STROKEAHA.117.019228
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。