文献速递脑血管病

短暂性脑缺血发作和卒中后逐跳血压变异性对预后的意义

Prognostic Significance of Blood Pressure Variability on Beat-to-Beat Monitoring After Transient Ischemic Attack and Stroke.
PubMed 文献 · Stroke · 2017-12-11

在短暂性脑缺血发作或非致残性卒中后6周内的520例患者中,逐跳血压变异性(BPV)独立于平均收缩压和危险因素预测复发性卒中及心血管事件,而动态血压监测的短期BPV无预测作用。

要点

  • 逐跳BPV独立预测复发性卒中和心血管事件。
  • 动态血压监测的短期BPV无预测作用。
  • 逐跳BPV可能是有用的附加心血管风险标志物。

核心结论

  • 逐跳BPV独立于平均收缩压和危险因素预测复发性卒中和心血管事件,而动态血压监测的短期BPV无预测作用。

研究设计与样本

  • 在短暂性脑缺血发作或非致残性卒中后6周内的连续患者中,测量5分钟逐跳BPV(Finometer)、1周家庭监测的逐日BPV和清醒动态血压监测的BPV。

主要发现

  • 逐跳BPV预测复发性卒中(每SD的风险比1.47 [1.12-1.91];P=0.005)和心血管事件(1.41 [1.08-1.83];P=0.01),独立于平均收缩压。
  • 调整年龄和性别后,逐跳BPV与卒中的风险比为1.47 [1.12-1.92];P=0.005。
  • 调整所有危险因素后,逐跳BPV与卒中的风险比为1.40 [1.00-1.94];P=0.047。
  • 逐日BPV与卒中的关联较弱(调整后风险比1.29 [0.97-1.71];P=0.08),但与心血管事件类似(1.41 [1.09-1.83];P=0.009)。
  • 动态血压监测的BPV无预测作用(卒中:0.89 [0.59-1.35];P=0.59;心血管事件:1.08 [0.77-1.52];P=0.65)。

临床怎么用

  • 逐跳BPV可能作为心血管风险的附加标志物,但需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: Visit-to-visit and day-to-day blood pressure (BP) variability (BPV) predict an increased risk of cardiovascular events but only reflect 1 form of BPV. Beat-to-beat BPV can be rapidly assessed and might also be predictive. METHODS: In consecutive patients within 6 weeks of transient ischemic attack or nondisabling stroke (Oxford Vascular Study), BPV (coefficient of variation) was measured beat-to-beat for 5 minutes (Finometer), day-to-day for 1 week on home monitoring (3 readings, 3× daily), and on awake ambulatory BP monitoring. BPV after 1-month standard treatment was related (Cox proportional hazards) to recurrent stroke and cardiovascular events for 2 to 5 years, adjusted for mean systolic BP. RESULTS: Among 520 patients, 26 had inadequate beat-to-beat recordings, and 22 patients were in atrial fibrillation. Four hundred five patients had all forms of monitoring. Beat-to-beat BPV predicted recurrent stroke and cardiovascular events independently of mean systolic BP (hazard ratio per group SD, stroke: 1.47 [1.12-1.91]; P=0.005; cardiovascular events: 1.41 [1.08-1.83]; P=0.01), including after adjustment for age and sex (stroke: 1.47 [1.12-1.92]; P=0.005) and all risk factors (1.40 [1.00-1.94]; P=0.047). Day-to-day BPV was less strongly associated with stroke (adjusted hazard ratio, 1.29 [0.97-1.71]; P=0.08) but similarly with cardiovascular events (1.41 [1.09-1.83]; P=0.009). BPV on awake ambulatory BP monitoring was nonpredictive (stroke: 0.89 [0.59-1.35]; P=0.59; cardiovascular events: 1.08 [0.77-1.52]; P=0.65). Despite a weak correlation (r=0.119; P=0.02), beat-to-beat BPV was associated with risk of recurrent stroke independently of day-to-day BPV (1.41 [1.05-1.90]; P=0.02). CONCLUSIONS: Beat-to-beat BPV predicted recurrent stroke and cardiovascular events, independently of mean systolic BP and risk factors but short-term BPV on ambulatory BP monitoring did not. Beat-to-beat BPV may be a useful additional marker of cardiovascular risk.

来源:Stroke,查看原文。版权归原作者所有。

引用

  1. Webb AJS, Mazzucco S, Li L, et al. Prognostic Significance of Blood Pressure Variability on Beat-to-Beat Monitoring After Transient Ischemic Attack and Stroke. Stroke. 2017. PMID: 29229726. doi:10.1161/STROKEAHA.117.019107

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。