文献速递脑血管病

ASPECTS与CT灌注核心体积评估超急性期梗死体积的比较

Evaluation of hyperacute infarct volume using ASPECTS and brain CT perfusion core volume.
PubMed 文献 · Neurology · 2017-05-17

本研究纳入59例急性前循环缺血性卒中患者,在CT成像后100分钟内完成平扫CT、CT灌注和MRI,比较ASPECTS与CT灌注核心体积检测急性MRI弥散病灶≥70 mL的准确性。结果显示两者准确性无显著差异(c统计量0.95 vs 0.87,p=0.17),CT灌注核心体积最佳截断值为≥50 mL(敏感度0.86,特异度0.97)。

要点

  • ASPECTS与CT灌注核心体积检测超急性期梗死体积准确性无显著差异。
  • CT灌注核心体积≥50 mL检测MRI弥散病灶≥70 mL的敏感度0.86、特异度0.97。
  • ASPECTS<7检测MRI弥散病灶≥70 mL的敏感度0.74、特异度0.86。

核心结论

  • CT灌注与ASPECTS预测超急性期MRI病灶体积的准确性无显著差异(c统计量0.95 vs 0.87,p=0.17)。

研究设计与样本

  • 观察性研究纳入59例急性前循环缺血性卒中患者,均在CT成像后100分钟内完成平扫CT、CT灌注和MRI。
  • ASPECTS由4名设盲的血管神经科医生计算。

主要发现

  • ASPECTS中位评分8分(IQR 5-9),CT灌注核心体积中位22 mL(IQR 10.4-71.9),MRI弥散病灶体积中位24.5 mL(IQR 10-63.9)。
  • CT灌注核心病灶覆盖急性MRI病灶体积的中位比例为100%(IQR 86%-100%),Pearson R=0.88,R²=0.77。

关键数值与推荐

  • 检测MRI弥散加权成像病灶≥70 mL的最佳ASPECTS截断值为<7(敏感度0.74,特异度0.86,Youden J=0.60)。
  • 检测MRI弥散加权成像病灶≥70 mL的最佳CT灌注核心体积截断值为≥50 mL(敏感度0.86,特异度0.97,Youden J=0.84)。

临床怎么用

  • 在超急性期前循环缺血性卒中,ASPECTS与CT灌注核心体积均可用于评估梗死体积,两者准确性无显著差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To compare the accuracy of Alberta Stroke Program Early Computed Tomography Score (ASPECTS) and CT perfusion to detect established infarction in acute anterior circulation stroke. METHODS: We performed an observational study in 59 acute anterior circulation ischemic stroke patients who underwent brain noncontrast CT, CT perfusion, and MRI within 100 minutes from CT imaging. ASPECTS scores were calculated by 4 blinded vascular neurologists. The accuracy of ASPECTS and CT perfusion core volume to detect an acute MRI diffusion lesion of ≥70 mL was evaluated using receiver operating characteristics analysis and optimum cutoff values were calculated using Youden J. RESULTS: Median ASPECTS score was 8 (interquartile range [IQR] 5-9). Median CT perfusion core volume was 22 mL (IQR 10.4-71.9). Median MRI diffusion lesion volume was 24.5 mL (IQR 10-63.9). No significant difference was found between the accuracy of CT perfusion and ASPECTS (c statistic 0.95 vs 0.87, p value for difference = 0.17). The optimum ASPECTS cutoff score to detect a diffusion-weighted imaging lesion ≥70 mL was <7 (sensitivity 0.74, specificity 0.86, Youden J = 0.60) and the optimum CT perfusion core volume cutoff was ≥50 mL (sensitivity 0.86, specificity 0.97, Youden J = 0.84). The CT perfusion core lesion covered a median of 100% (IQR 86%-100%) of the acute MRI lesion volume (Pearson R = 0.88; R2 = 0.77). CONCLUSIONS: We found no significant difference between the accuracy of CT perfusion and ASPECTS to predict hyperacute MRI lesion volume in ischemic stroke.

来源:Neurology,查看原文。版权归原作者所有。

引用

  1. Demeestere J, Garcia-Esperon C, Garcia-Bermejo P, et al. Evaluation of hyperacute infarct volume using ASPECTS and brain CT perfusion core volume. Neurology. 2017. PMID: 28515270. doi:10.1212/WNL.0000000000004028

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。