文献速递脑血管病

非门控心脏CT血管造影检测急性缺血性卒中栓塞源

Nongated Cardiac Computed Tomographic Angiograms for Detection of Embolic Sources in Acute Ischemic Stroke.
PubMed 文献 · Stroke · 2017-04-06

前瞻性纳入20例发病4.5小时内的急性缺血性卒中患者,在常规非ECG门控CT血管造影中扩大z轴覆盖至膈顶以纳入心脏,不增加对比剂剂量。3例(15%)发现异常:左心室血栓、Stanford A型主动脉夹层、左心耳血栓,两例血栓经TEE确认并紧急抗凝。无对比剂肾病发生,辐射剂量略增。

要点

  • 扩大非门控CTA覆盖至心脏可检测高危心源性栓塞源。
  • 20例中3例发现异常,包括左心室血栓、主动脉夹层和左心耳血栓。
  • 不增加对比剂剂量,无对比剂肾病,辐射剂量仅轻度增加。

核心结论

  • 在常规非ECG门控CTA中纳入心脏和升主动脉可增强现有成像模式,不增加对比剂肾病发生率且辐射剂量增加极小,有助于检测急性卒中患者的高危心源性和主动脉栓塞源。

研究设计与样本

  • 前瞻性招募20例发病4.5小时内的急性缺血性卒中患者,扩大非ECG门控CTA的纵向覆盖至膈顶以包括心脏。

主要发现

  • 20例中3例(15%)发现异常:左心室血栓、Stanford A型主动脉夹层和左心耳血栓。
  • 两例血栓经经食管超声心动图确认,次日紧急启动抗凝治疗。
  • 随访中无患者发生对比剂肾病。
  • 辐射剂量从平均4.26 mSV(范围3.88-4.70 mSV)略增至5.17 mSV(范围3.95-6.25 mSV)。

关键数值与推荐

  • 对比剂为Omnipaque 350,注射速率3-4 mL/s,总量60-80 mL,团注追踪触发。
  • 心脏和主动脉图像以5 mm层厚在3个正交平面重建。
  • 图像由放射科和心脏科医生判读,并与24小时内进行的经胸或经食管超声心动图相关。

临床怎么用

  • 在急性卒中初次评估中,可考虑扩大非ECG门控CTA的z轴覆盖至心脏以筛查高危栓塞源。
  • 发现心内血栓或主动脉夹层可指导紧急抗凝或其他治疗决策。

局限性

  • 样本量小(20例),为可行性研究。
  • 未设对照组,辐射剂量轻度增加。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: We assessed the feasibility of obtaining diagnostic quality images of the heart and thoracic aorta by extending the z axis coverage of a non-ECG-gated computed tomographic angiogram performed in the primary evaluation of acute stroke without increasing the contrast dose. METHODS: Twenty consecutive patients with acute ischemic stroke within the 4.5 hours of symptom onset were prospectively recruited. We increased the longitudinal coverage to the domes of the diaphragm to include the heart. Contrast administration (Omnipaque 350) remained unchanged (injected at 3-4 mL/s; total 60-80 mL, triggered by bolus tracking). Images of the heart and aorta, reconstructed at 5 mm slice thickness in 3 orthogonal planes, were read by a radiologist and cardiologist, findings conveyed to the treating neurologist, and correlated with the transthoracic or transesophageal echocardiogram performed within the next 24 hours. RESULTS: Of 20 patients studied, 3 (15%) had abnormal findings: a left ventricular thrombus, a Stanford type A aortic dissection, and a thrombus of the left atrial appendage. Both thrombi were confirmed by transesophageal echocardiography, and anticoagulation was started urgently the following day. None of the patients developed contrast-induced nephropathy on follow-up. The radiation dose was slightly increased from a mean of 4.26 mSV (range, 3.88-4.70 mSV) to 5.17 (range, 3.95 to 6.25 mSV). CONCLUSIONS: Including the heart and ascending aorta in a routine non-ECG-gated computed tomographic angiogram enhances an existing imaging modality, with no increased incidence of contrast-induced nephropathy and minimal increase in radiation dose. This may help in the detection of high-risk cardiac and aortic sources of embolism in acute stroke patients.

来源:Stroke,查看原文。版权归原作者所有。

引用

  1. Yeo LLL, Holmin S, Andersson T, et al. Nongated Cardiac Computed Tomographic Angiograms for Detection of Embolic Sources in Acute Ischemic Stroke. Stroke. 2017. PMID: 28386043. doi:10.1161/STROKEAHA.117.016903

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。