动脉自旋标记定量急性卒中连续脑血流量
结果显示缺血核心区平均脑血流量最低(17±23 mL/100 g/min),其次为早期梗死增长区(21±26 mL/100 g/min)和晚期梗死增长区(25±35 mL/100 g/min;ANOVA P<0.0001),但患者间连续脑血流量值存在明显重叠。结论认为灌注动态仅部分解释组织转归,代谢和组织易感性等因素也可能影响。
要点
- 动脉自旋标记可无对比剂重复定量急性卒中患者脑血流量。
- 缺血核心区脑血流量最低,梗死增长区次之,组间差异显著。
- 患者间连续脑血流量值重叠明显,灌注动态仅部分解释组织转归。
核心结论
- 灌注动态仅部分解释卒中后组织转归,代谢和组织易感性等因素也可能影响组织结局。
研究设计与样本
- 在6名健康志愿者中评估重复性,并与患者对侧区域比较。
主要发现
- 患者对侧区域脑血流量个体间变异显著,但扫描时间点间无显著变异(均值±标准差:53±42 mL/100 g/min)。
- 缺血区域内平均脑血流量:缺血核心区17±23 mL/100 g/min,早期梗死增长区21±26 mL/100 g/min,晚期梗死增长区25±35 mL/100 g/min(ANOVA P<0.0001)。
- 患者间就诊时和连续脑血流量值存在明显重叠。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND PURPOSE: Perfusion-weighted imaging is used to select patients with acute ischemic stroke for intervention, but knowledge of cerebral perfusion can also inform the understanding of ischemic injury. Arterial spin labeling allows repeated measurement of absolute cerebral blood flow (CBF) without the need for exogenous contrast. The aim of this study was to explore the relationship between dynamic CBF and tissue outcome in the month after stroke onset. METHODS: Patients with nonlacunar ischemic stroke underwent ≤5 repeated magnetic resonance imaging scans at presentation, 2 hours, 1 day, 1 week, and 1 month. Imaging included vessel-encoded pseudocontinuous arterial spin labeling using multiple postlabeling delays to quantify CBF in gray matter regions of interest. Receiver-operator characteristic curves were used to predict tissue outcome using CBF. Repeatability was assessed in 6 healthy volunteers and compared with contralateral regions of patients. Diffusion-weighted and T2-weighted fluid attenuated inversion recovery imaging were used to define tissue outcome. RESULTS: Forty patients were included. In contralateral regions of patients, there was significant variation of CBF between individuals, but not between scan times (mean±SD: 53±42 mL/100 g/min). Within ischemic regions, mean CBF was lowest in ischemic core (17±23 mL/100 g/min), followed by regions of early (21±26 mL/100 g/min) and late infarct growth (25±35 mL/100 g/min; ANOVA P<0.0001). Between patients, there was marked overlap in presenting and serial CBF values. CONCLUSIONS: Knowledge of perfusion dynamics partially explained tissue fate. Factors such as metabolism and tissue susceptibility are also likely to influence tissue outcome.
引用
- Harston GW, Okell TW, Sheerin F, et al. Quantification of Serial Cerebral Blood Flow in Acute Stroke Using Arterial Spin Labeling. Stroke. 2016. PMID: 27879446. doi:10.1161/STROKEAHA.116.014707
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。