大血管闭塞卒中血栓成分的影像组学分析
结果显示影像组学可无创评估血栓成分,心源性栓塞血栓以红细胞为主者占72%,大动脉粥样硬化性占30%,隐源性占50%。
要点
- 平扫CT影像组学特征与血栓红细胞成分相关,可无创推断血栓组成。
- 心源性栓塞血栓中72%以红细胞为主,高于大动脉粥样硬化性血栓的30%。
- 该技术有望辅助卒中病因分型,但样本量有限,尚需验证。
核心结论
- 影像组学是一种有前景的无创血栓成分表征技术。
研究设计与样本
- 第二阶段为回顾性研究,分析150例不同病因缺血性卒中的平扫CT影像组学。
主要发现
- 总能量(OR=1.35,95%CI=1.20-1.54,p<0.001)和大依赖高灰度强调(OR=1.18,95%CI=1.07-1.32,p=0.01)与红细胞相关。
- 上述特征与平扫CT上>70%红细胞成分相关(Rho=0.752和Rho=0.815)。
- 影像组学提示红细胞为主成分者:心源性栓塞72%、大动脉粥样硬化性30%、隐源性50%。
关键数值与推荐
- 总能量OR=1.35(95%CI=1.20-1.54,p<0.001)与红细胞成分相关。
- 大依赖高灰度强调OR=1.18(95%CI=1.07-1.32,p=0.01)与红细胞成分相关。
- 平扫CT影像组学特征与>70%红细胞成分的相关系数Rho分别为0.752和0.815。
临床怎么用
- 平扫CT影像组学可用于无创推测大血管闭塞血栓成分,辅助判断卒中病因。
- 心源性栓塞血栓更常见红细胞为主成分,大动脉粥样硬化性血栓则较少。
局限性
- 回顾性数据集仅150例,结论需更大样本验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Clot composition may offer insights into the mechanism of ischemic stroke. Radiomics, a noninvasive imaging technique, enables tissue characterization through radiomic features (RFs). We aimed to evaluate clot composition using radiomics on non-contrast computed tomography (NCCT). METHODS: In the first phase, we conducted a prospective study comparing RFs with histopathology in thrombi retrieved via mechanical thrombectomy (MT). Thrombi were imaged using micro-computed tomography (micro-CT) and analyzed histologically. Matched micro-CT and histological slices identified red blood cells (RBCs) and fibrin-rich regions. RFs were extracted, and multivariate logistic regression identified features associated with each component. Spearman's correlation was used to assess associations between RFs and percentage composition. The same clots were localized on pre-MT NCCT, and RFs were extracted. Micro-CT and NCCT RFs were correlated to enable histology-informed interpretation. Receiver operating characteristic analysis evaluated the ability of NCCT RFs to discriminate clot composition. In the second phase, radiomics was applied to a retrospective NCCT dataset from patients with ischemic stroke with varying etiologies. RESULTS: Ten thrombi were analyzed using micro-CT. Total energy (odds ratio [OR] = 1.35, 95% confidence interval [CI] = 1.20-1.54, p < 0.001) and large dependence high gray level emphasis (OR = 1.18, 95% CI = 1.07-1.32, p = 0.01) were associated with RBCs and correlated with >70% RBCs composition on NCCT (Rho = 0.752 and Rho = 0.815). Subsequently, 150 NCCT scans were analyzed, including 50 cardioembolic, 50 large artery atherosclerosis (LAA), and 50 cryptogenic strokes. Radiomic analysis indicated RBCs-predominant composition in 72% of cardioembolic, 30% of LAA, and 50% of cryptogenic clots. INTERPRETATION: Radiomics is a promising, noninvasive technique for characterizing clot composition. ANN NEUROL 2026;99:1179-1188.
引用
- Gudino A, Sagues E, Dier C, et al. Clot Composition Profiling in Large Vessel Occlusion Stroke Via Radiomics. Ann Neurol. 2026. PMID: 41542736. doi:10.1002/ana.78160
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。