文献速递脑血管病

心脏CT与超声心动图检测缺血性卒中患者心内血栓的系统综述与43项研究的Meta分析

Cardiac CT vs Echocardiography for Intracardiac Thrombus Detection in Ischemic Stroke: A Systematic Review and Meta-Analysis of 43 Studies.
PubMed 文献 · Neurology · 2024-09-13

该系统综述与Meta分析对比心脏CT(CCT)与超声心动图检测心内血栓,纳入43项研究共9552例患者。CCT总体敏感度98.38%(95%CI 89.2-99.78)、特异度96.0%(95%CI 92.55-97.88),诊断比值比98.59(95%CI 44.05-220.69);延迟期心电门控CCT敏感度最高达100%(95%CI 0-100)。作者认为CCT表现高敏感度与特异度,但需大规模研究进一步评估。

要点

  • CCT检测心内血栓总体敏感度98.38%、特异度96.0%,诊断比值比98.59。
  • 延迟期心电门控CCT敏感度100%(95%CI 0-100),早期非门控CCT敏感度94.31%(95%CI 28.58-99.85)。
  • 异质性主要见于特异度与诊断比值比估计;作者认为需大规模研究进一步评估CCT。

核心结论

  • 与常规超声心动图相比,CCT检测心内血栓显示高敏感度、高特异度和高诊断比值比。
  • 作者认为需大规模研究进一步评估CCT作为识别心内血栓及其他心源性卒中来源的替代方法。

研究设计与样本

  • 系统综述与Meta分析,检索4个数据库至2023年9月8日,纳入43项研究共9552例患者。
  • 检索词包括echocardiograph、CT、TEE、imaging、stroke、undetermined、cryptogenic等组合,按PRISMA指南报告。
  • 采用QUADAS-2工具评估偏倚风险,使用随机效应Meta分析计算诊断指标。

主要发现

  • CCT对比超声心动图检测心内血栓的总体敏感度为98.38%(95%CI 89.2-99.78),特异度为96.0%(95%CI 92.55-97.88)。
  • 延迟期心电门控CCT敏感度最高为100%(95%CI 0-100),早期非门控CCT敏感度为94.31%(95%CI 28.58-99.85)。
  • 诊断比值比为98.59(95%CI 44.05-220.69),异质性见于特异度和诊断比值比估计。
  • 偏倚风险评估显示流程与时机、指标试验和患者选择领域以低风险为主,参考标准领域以不明确风险为主。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 缺乏随机对照研究。
  • 分析未评估瓣膜病、心脏功能和主动脉弓疾病等其他心源性栓塞来源。
  • 作者认为需大规模研究进一步评估CCT。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVES: Ischemic stroke, a leading cause of mortality, necessitates understanding its mechanism for effective prevention. Echocardiography, especially transesophageal echocardiography (TEE), is the gold standard for detection of cardiac sources of stroke including left atrial thrombus, although its invasiveness, operator skill dependence, and limited availability in some centers prompt exploration of alternatives, such as cardiac CT (CCT). We conducted a systematic review and meta-analysis assessing the ability of CCT in the detection of intracardiac thrombus compared with echocardiography. METHODS: We searched 4 databases up through September 8, 2023. Major search terms included a combination of the terms "echocardiograph," "CT," "TEE," "imaging," "stroke," "undetermined," and "cryptogenic." The current systematic literature review of the English language literature was reported in adherence to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses reporting guidelines. We assessed risk of bias using the QUADAS-2 tool and used random-effects meta-analysis to calculate different diagnostic metrics. RESULTS: The meta-analysis investigating CCT vs echocardiography for intracardiac thrombus detection yielded a total of 43 studies of 9,552 patients. Risk-of-bias assessment revealed a predominantly low risk of bias in the flow and timing, index test, and patient selection domains and a predominantly unclear risk of bias in the reference standard domain. The analysis revealed an overall sensitivity of 98.38% (95% CI 89.2-99.78) and specificity of 96.0% (95% CI 92.55-97.88). Subgroup analyses demonstrated that delayed-phase, electrocardiogram-gated CCT had the highest sensitivity (100%; 95% CI 0-100) while early-phase, nongated CCT exhibited a sensitivity of 94.31% (95% CI 28.58-99.85). The diagnostic odds ratio was 98.59 (95% CI 44.05-220.69). Heterogeneity was observed, particularly in specificity and diagnostic odds ratio estimates. DISCUSSION: CCT demonstrates high sensitivity, specificity, and diagnostic odds ratios in detecting intracardiac thrombus compared with traditional echocardiography. Limitations include the lack of randomized controlled studies, and other cardioembolic sources of stroke such as valvular disease, cardiac function, and aortic arch disease were not examined in our analysis. Large-scale studies are warranted to further evaluate CCT as a promising alternative for identifying intracardiac thrombus and other sources of cardioembolic stroke.

来源:Neurology,查看原文。版权归原作者所有。

引用

  1. Ghozy S, Liu M, Kobeissi H, et al. Cardiac CT vs Echocardiography for Intracardiac Thrombus Detection in Ischemic Stroke: A Systematic Review and Meta-Analysis of 43 Studies. Neurology. 2024. PMID: 39270155. doi:10.1212/WNL.0000000000209771