文献速递帕金森病与运动障碍

神经型Wilson病的独特金属沉积模式:7T磁敏感加权成像的启示

Distinctive Pattern of Metal Deposition in Neurologic Wilson Disease: Insights From 7T Susceptibility-Weighted Imaging.
PubMed 文献 · Neurology · 2024-06-03

本研究利用7T磁敏感加权成像(SWI)在神经型Wilson病(NWD)患者中识别出苍白球外侧缘高信号带征,该征象在41例NWD中38例阳性,而在31例无神经症状WD、22例单等位基因携带者、41例健康对照及多种帕金森叠加综合征患者中均阴性,鉴别NWD与健康对照的敏感度92.7%、特异度100%。

要点

  • 7T SWI显示的苍白球外侧缘高信号带征对神经型Wilson病诊断敏感度92.7%、特异度100%。
  • 该征象半定量评分与神经功能严重程度呈正相关(ρ=0.682,95%CI 0.467-0.821,p<0.001)。
  • 神经型Wilson病患者豆状核磁敏感值增高,区域权重以苍白球外侧部和壳核内侧部为著。

核心结论

  • 苍白球外侧缘高信号带征对神经型Wilson病的诊断和鉴别诊断具有高敏感度和极佳特异度。
  • 该征象与神经型Wilson病豆状核的特殊金属沉积模式相关,可被视为一种新型神经影像生物标志物。

研究设计与样本

  • 研究纳入Wilson病患者、单染色体单等位基因ATP7B变异携带者及健康对照,并根据检查期间有无神经系统症状分为神经型Wilson病(NWD)和非神经型Wilson病(nNWD)。
  • 另纳入早发性帕金森病、多系统萎缩、进行性核上性麻痹及脑铁沉积神经变性病患者进行探索性比较分析。
  • 所有参与者均接受7T T1、T2及高分辨率SWI扫描,并进行定量磁敏感成像和主成分分析。

主要发现

  • 在神经型Wilson病患者中识别出由苍白球外侧缘高信号带构成的线性信号强度变化,命名为「苍白球外侧缘高信号带征」。
  • 该征象在41例神经型Wilson病患者中38例检出,而在31例非神经型Wilson病、15例早发性帕金森病、30例多系统萎缩、15例进行性核上性麻痹、12例脑铁沉积神经变性病、22例单等位基因ATP7B变异携带者及41例健康对照中均为阴性。
  • 该征象鉴别神经型Wilson病与健康对照的敏感度为92.7%,特异度为100%。
  • 半定量量表测量的苍白球外侧缘高信号带征严重程度与神经功能严重程度呈正相关(ρ=0.682,95%CI 0.467-0.821,p<0.001)。
  • 神经型Wilson病患者豆状核磁敏感值增高,区域权重以苍白球外侧部和壳核内侧部为著。

关键数值与推荐

  • 苍白球外侧缘高信号带征诊断神经型Wilson病的敏感度92.7%、特异度100%。
  • 该征象半定量评分与神经功能严重程度正相关(ρ=0.682,95%CI 0.467-0.821,p<0.001)。
  • 研究提供II级证据表明7T SWI MRI上的苍白球外侧缘高信号带征可准确诊断神经型Wilson病。

临床怎么用

  • 作者认为苍白球外侧缘高信号带征可被视为神经型Wilson病的一种新型神经影像生物标志物。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVES: Noninvasive and accurate biomarkers of neurologic Wilson disease (NWD), a rare inherited disorder, could reduce diagnostic error or delay. Excessive subcortical metal deposition seen on susceptibility imaging has suggested a characteristic pattern in NWD. With submillimeter spatial resolution and increased contrast, 7T susceptibility-weighted imaging (SWI) may enable better visualization of metal deposition in NWD. In this study, we sought to identify a distinctive metal deposition pattern in NWD using 7T SWI and investigate its diagnostic value and underlying pathophysiologic mechanism. METHODS: Patients with WD, healthy participants with monoallelic ATP7B variant(s) on a single chromosome, and health controls (HCs) were recruited. NWD and non-NWD (nNWD) were defined according to the presence or absence of neurologic symptoms during investigation. Patients with other diseases with comparable clinical or imaging manifestations, including early-onset Parkinson disease (EOPD), multiple system atrophy (MSA), progressive supranuclear palsy (PSP), and neurodegeneration with brain iron accumulation (NBIA), were additionally recruited and assessed for exploratory comparative analysis. All participants underwent 7T T1, T2, and high-resolution SWI scanning. Quantitative susceptibility mapping and principal component analysis were performed to illustrate metal distribution. RESULTS: We identified a linear signal intensity change consisting of a hyperintense strip at the lateral border of the globus pallidus in patients with NWD. We termed this feature "hyperintense globus pallidus rim sign." This feature was detected in 38 of 41 patients with NWD and was negative in all 31 nNWD patients, 15 patients with EOPD, 30 patients with MSA, 15 patients with PSP, and 12 patients with NBIA; 22 monoallelic ATP7B variant carriers; and 41 HC. Its sensitivity to differentiate between NWD and HC was 92.7%, and specificity was 100%. Severity of the hyperintense globus pallidus rim sign measured by a semiquantitative scale was positively correlated with neurologic severity (ρ = 0.682, 95% CI 0.467-0.821, p < 0.001). Patients with NWD showed increased susceptibility in the lenticular nucleus with high regional weights in the lateral globus pallidus and medial putamen. DISCUSSION: The hyperintense globus pallidus rim sign showed high sensitivity and excellent specificity for diagnosis and differential diagnosis of NWD. It is related to a special metal deposition pattern in the lenticular nucleus in NWD and can be considered as a novel neuroimaging biomarker of NWD. CLASSIFICATION OF EVIDENCE: The study provides Class II evidence that the hyperintense globus pallidus rim sign on 7T SWI MRI can accurately diagnose neurologic WD.

来源:Neurology,查看原文。版权归原作者所有。

引用

  1. Su D, Zhang Z, Zhang Z, et al. Distinctive Pattern of Metal Deposition in Neurologic Wilson Disease: Insights From 7T Susceptibility-Weighted Imaging. Neurology. 2024. PMID: 38830145. doi:10.1212/WNL.0000000000209478

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。