短期暴露于空气污染与缺血性卒中:系统综述与荟萃分析
该系统综述与荟萃分析纳入110项观察性研究、共18,035,408例缺血性卒中,检索至2023年2月。结果显示短期暴露于NO2、O3、CO、SO2、PM1、PM2.5和PM10浓度升高与卒中发病显著相关,NO2、SO2、PM2.5和PM10浓度升高与卒中死亡相关。
要点
- 短期暴露于NO2、O3、CO、SO2及PM1、PM2.5、PM10浓度升高与缺血性卒中发病显著相关。
- NO2、SO2、PM2.5和PM10浓度升高与缺血性卒中死亡相关。
- 纳入研究以亚洲为主(58.8%),非洲无纳入研究。
核心结论
- 气态和颗粒物空气污染物与卒中发生率和死亡率之间存在强且显著的相关性。
- 这种紧密的时间关联凸显了实施全球倡议以制定减少空气污染政策的重要性,从而减轻缺血性卒中负担及其后果。
研究设计与样本
- 系统综述与荟萃分析,检索MEDLINE、Scopus、Cochrane中央对照试验注册库(CENTRAL)和Web of Sciences数据库,截至2023年2月,无语言限制。
- 纳入观察性或干预性研究,评估短期暴露于空气污染物与缺血性卒中发病率和死亡率的相关性;短期暴露定义为卒中发病前5天内发生的暴露。
- 共纳入110项观察性研究,包含18,035,408例缺血性卒中病例;亚洲占58.8%,欧洲占24.6%,美洲占16.7%,非洲无纳入研究。
主要发现
- NO2浓度升高与卒中发病显著相关(RR=1.28;95%CI 1.21-1.36)。
- O3浓度升高与卒中发病显著相关(RR=1.05;95%CI 1.03-1.07)。
- CO浓度升高与卒中发病显著相关(RR=1.26;95%CI 1.21-1.32)。
- SO2浓度升高与卒中发病显著相关(RR=1.15;95%CI 1.11-1.19)。
- PM1浓度升高与卒中发病显著相关(RR=1.09;95%CI 1.06-1.12);PM2.5浓度升高与卒中发病显著相关(RR=1.15;95%CI 1.13-1.17);PM10浓度升高与卒中发病显著相关(RR=1.14;95%CI 1.12-1.16)。
关键数值与推荐
- NO2浓度升高与卒中死亡相关(RR=1.33;95%CI 1.07-1.65)。
- SO2浓度升高与卒中死亡相关(RR=1.60;95%CI 1.05-2.44)。
- PM2.5浓度升高与卒中死亡相关(RR=1.09;95%CI 1.04-1.15)。
- PM10浓度升高与卒中死亡相关(RR=1.02;95%CI 1.00-1.04)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVES: Approximately 5 million fatalities occur annually due to stroke, along with its substantial effects on patient well-being and functional impairment. Research has established a connection between extended exposure to air pollutants and ischemic stroke. However, the link between short-term exposure to air pollutants and stroke remains less definitive. METHODS: A comprehensive search was conducted on MEDLINE, Scopus, the Cochrane Central Register of Controlled Trials (CENTRAL), and Web of Sciences databases up until February 2023, without any language restrictions. The inclusion criteria encompassed observational or interventional studies that examined the correlation between short-term exposure to air pollutants (carbon monoxide [CO], sulfur dioxide [SO2], nitrogen dioxide [NO2], ozone [O3]) and particulate matter with diameters of less than 1 µm, less than 2.5 µm, or less than 10 µm (PM1, PM2.5, and PM10), with the incidence and mortality of ischemic stroke. Short-term exposure was defined as exposure occurring within 5 days of the onset of stroke. RESULTS: A total of 18,035,408 cases of ischemic stroke were included in the analysis, derived from 110 observational studies. Asia accounted for most included studies, representing 58.8% of the total. By contrast, Europe and the Americas contributed 24.6% and 16.7% of the studies, respectively. Notably, none of the included studies were conducted in Africa. Stroke incidence was significantly associated with an increase in the concentration of NO2 (RR = 1.28; 95% CI 1.21-1.36), O3 (RR = 1.05; 95% CI 1.03-1.07), CO (RR = 1.26; 95% CI 1.21-1.32), SO2 (RR = 1.15; 95% CI 1.11-1.19), PM1 (RR = 1.09; 95% CI 1.06-1.12), PM2.5 (RR = 1.15; 95% CI 1.13-1.17), and PM10 (RR = 1.14; 95% CI 1.12-1.16). Moreover, an increase in the concentration of NO2 (RR = 1.33; 95% CI 1.07-1.65), SO2 (RR = 1.60; 95% CI 1.05-2.44), PM2.5 (RR = 1.09; 95% CI 1.04-1.15), and PM10 (RR = 1.02; 95% CI 1.00-1.04) was associated with an increase in stroke mortality. DISCUSSION: There is a strong and significant correlation between gaseous and particulate air pollutants and the occurrence and mortality rates of stroke. This close temporal association underscores the importance of implementing global initiatives to develop policies aimed at reducing air pollution. By doing so, alleviate the burden of ischemic stroke and its consequences.
引用
- Toubasi A, Al-Sayegh TN. Short-term Exposure to Air Pollution and Ischemic Stroke: A Systematic Review and Meta-analysis. Neurology. 2023. PMID: 37758483. doi:10.1212/WNL.0000000000207856
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。