PubMed 文献 · Neurology · 2023-05-15

研究纳入595名社区居住步态正常的老年人,其中101例存在认知障碍,利用可穿戴惯性传感器采集步速和步态变异性构建逻辑回归模型,在开发集(AUC=0.788)和验证集(AUC=0.811)均显示良好诊断性能,与MMSE模型性能相当。

要点

  • 可穿戴惯性传感器采集的步速和步态变异性可用于区分认知障碍与正常认知。
  • 步态模型在开发集AUC=0.788、验证集AUC=0.811,与MMSE模型无显著差异。
  • 步态模型最佳截断值为>-1.56。

核心结论

  • 基于可穿戴惯性传感器的步态模型可能成为老年人认知障碍的有前景的诊断标志物。

研究设计与样本

  • 研究纳入来自韩国认知老化与痴呆纵向研究的社区居住步态正常老年人,使用置于身体质心的可穿戴惯性传感器在14米长步道上以舒适步速行走三次采集步态特征。
  • 将全部数据集随机分为开发集(80%)和验证集(20%),在开发集中用逻辑回归分析构建认知障碍分类模型,并在验证集中验证。
  • 共纳入595名参与者,其中101例发生认知障碍。

主要发现

  • 模型包含步速和时间步态变异性,在开发集中分类认知障碍与正常认知的AUC=0.788(95% CI 0.748-0.823,p < 0.001)。
  • 模型在验证集中AUC=0.811(95% CI 0.729-0.877,p < 0.001)。
  • 开发集中步态模型与MMSE模型的AUC差异=0.026(标准误=0.043,z统计量=0.610,p=0.542)。
  • 验证集中步态模型与MMSE模型的AUC差异=0.070(标准误=0.073,z统计量=0.956,p=0.330)。
  • 步态模型的最佳截断值为>-1.56。

关键数值与推荐

  • 步态模型最佳截断值:>-1.56。
  • 开发集AUC=0.788(95% CI 0.748-0.823,p < 0.001)。
  • 验证集AUC=0.811(95% CI 0.729-0.877,p < 0.001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVES: Gait changes are potential markers of cognitive disorders (CDs). We developed a model for classifying older adults with CD from those with normal cognition using gait speed and variability captured from a wearable inertial sensor and compared its diagnostic performance for CD with that of the model using the Mini-Mental State Examination (MMSE). METHODS: We enrolled community-dwelling older adults with normal gait from the Korean Longitudinal Study on Cognitive Aging and Dementia and measured their gait features using a wearable inertial sensor placed at the center of body mass while they walked on a 14-m long walkway thrice at comfortable paces. We randomly split our entire dataset into the development (80%) and validation (20%) datasets. We developed a model for classifying CD using logistic regression analysis from the development dataset and validated it in the validation dataset. In both datasets, we compared the diagnostic performance of the model with that using the MMSE. We estimated optimal cutoff score of our model using receiver operator characteristic analysis. RESULTS: In total, 595 participants were enrolled, of which 101 of them experienced CD. Our model included both gait speed and temporal gait variability and exhibited good diagnostic performance for classifying CD from normal cognition in both the development (area under the receiver operator characteristic curve [AUC] = 0.788, 95% CI 0.748-0.823, p < 0.001) and validation datasets (AUC = 0.811, 95% CI 0.729-0.877, p < 0.001). Our model showed comparable diagnostic performance for CD with that of the model using the MMSE in both the development (difference in AUC = 0.026, standard error [SE] = 0.043, z statistic = 0.610, p = 0.542) and validation datasets (difference in AUC = 0.070, SE = 0.073, z statistic = 0.956, p = 0.330). The optimal cutoff score of the gait-based model was >-1.56. DISCUSSION: Our gait-based model using a wearable inertial sensor may be a promising diagnostic marker of CD in older adults. CLASSIFICATION OF EVIDENCE: This study provides Class III evidence that gait analysis can accurately distinguish older adults with CDs from healthy controls.

来源:Neurology,查看原文。版权归原作者所有。