文献速递脑血管病

缺血性卒中后平扫计算机断层扫描评估脑组织存活性

Assessing Brain Tissue Viability on Nonenhanced Computed Tomography After Ischemic Stroke.
PubMed 文献 · Stroke · 2023-01-05

该回顾性研究纳入2017至2020年King Abdulaziz大学医院142例缺血性卒中患者,以CT灌注为参考标准,评估平扫CT上缺血与正常脑组织的衰减比值及定性特征。结果显示识别半暗带的最佳CT衰减比值>0.87,敏感度86%、特异度91%(AUC 0.95,95%CI 0.92-0.98;P<0.0001);孤立性肿胀对半暗带高度特异(70/72,97%),而可见低衰减不总是代表核心。

要点

  • 平扫CT衰减比值>0.87可识别CT灌注定义的半暗带,敏感度86%、特异度91%(AUC 0.95,95%CI 0.92-0.98;P<0.0001)。
  • 孤立性肿胀通常对应CT灌注半暗带(70/72,97%),对半暗带高度特异。
  • 可见低衰减不总是核心,56%(141/254)对应核心、43%(109/254)对应半暗带,可通过测量病灶衰减比值鉴别。

核心结论

  • 缺血性卒中后,脑组织存活性可用平扫CT评估;孤立性肿胀对半暗带高度特异;可见低衰减不总是核心,近半数此类病灶在同期CT灌注上为半暗带,可通过测量病灶衰减比值加以鉴别。

研究设计与样本

  • 回顾性评估2017至2020年在King Abdulaziz大学医院连续就诊的缺血性卒中患者,纳入有基线平扫CT且同期CT灌注可见缺陷者,以CT灌注为参考标准。
  • 共纳入142例患者(86例男性),平均年龄61±14岁;至平扫CT的中位时间261分钟(四分位距173-382)。
  • 测量206个缺血病灶(124个半暗带、82个核心)在平扫CT上的衰减比值(缺血/正常),并用ROC曲线下面积估计半暗带的最佳CT衰减比值。
  • 每例患者定性评估患侧大脑半球8个区域:平扫CT上为正常、低衰减(伴或不伴肿胀)或孤立性肿胀,CT灌注上为正常、半暗带或核心。

主要发现

  • 识别半暗带的最佳CT衰减比值为>0.87,敏感度86%、特异度91%(AUC 0.95,95%CI 0.92-0.98;P<0.0001)。
  • 定性评估976个脑区(72个孤立性肿胀、254个低衰减);平扫CT上孤立性肿胀通常对应CT灌注半暗带(70/72,97%)。
  • 平扫CT可见低衰减者中,141/254(56%)对应核心、109/254(43%)对应半暗带。
  • CT灌注核心病灶在平扫CT上很少表现为正常(13/155,8%)。

关键数值与推荐

  • 平扫CT衰减比值>0.87用于识别CT灌注定义的半暗带,敏感度86%、特异度91%(AUC 0.95,95%CI 0.92-0.98;P<0.0001)。
  • 平扫CT孤立性肿胀对CT灌注半暗带的对应率为70/72(97%)。
  • 平扫CT可见低衰减对CT灌注核心的对应率为141/254(56%),对半暗带的对应率为109/254(43%)。

临床怎么用

  • 作者认为,缺血性卒中后脑组织存活性可用平扫CT评估;孤立性肿胀对半暗带高度特异;可见低衰减不总是核心,近半数此类病灶在同期CT灌注上为半暗带,可通过测量病灶衰减比值加以鉴别。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Treatment for ischemic stroke can be offered beyond conventional time limits for patients with favorable computed tomography perfusion (CTP), but this is not universally available. We sought a threshold for brain attenuation on nonenhanced computed tomography (NECT) to differentiate CTP-defined penumbra vs core, and correlated NECT features with CTP. METHODS: We retrospectively assessed consecutive patients presenting to King Abdulaziz University Hospital with ischemic stroke (2017-2020), baseline NECT, and a visible defect on concurrent CTP. Using CTP as the reference standard, we measured the attenuation of ischemic and healthy contralateral brain on NECT to produce attenuation ratios (ischemic/normal) for penumbra and core. We used area under the receiver operating characteristic curve to estimate the optimal computed tomography (CT) attenuation ratio for penumbra. Per patient, we qualitatively assessed 8 regions within the affected cerebral hemisphere: on NECT as normal, hypoattenuating (with/out swelling), or isolated swelling and on CTP as normal, penumbra, or core. We sought associations between isolated swelling and penumbra, and between hypoattenuation and core. RESULTS: We include 142 patients (86 male), mean age 61±14 years. Median 261 minutes (interquartile range, 173-382) to NECT. We measured 206 ischemic lesions (124 penumbra, 82 core). Optimal CT attenuation ratio for identifying penumbra was >0.87, with 86% sensitivity 91% specificity (area under the receiver operating characteristic curve, 0.95 [95% CI, 0.92-0.98]; P<0.0001). We qualitatively assessed 976 cerebral regions (72 isolated swelling, 254 hypoattenuation). On NECT, isolated swelling usually corresponded to CTP penumbra (70/72, 97%), whereas visible NECT hypoattenuation was found with core (141/254, 56%) and penumbra (109/254, 43%). CTP core lesions were rarely normal on NECT (13/155, 8%). CONCLUSIONS: After ischemic stroke, brain tissue viability can be assessed using NECT. Isolated swelling is highly specific to penumbra. Visible hypoattenuation does not always represent core, nearly half of such lesions were penumbral on concurrent CTP and can be differentiated by measuring lesion attenuation.

来源:Stroke,查看原文。版权归原作者所有。

引用

  1. Alzahrani A, Zhang X, Albukhari A, et al. Assessing Brain Tissue Viability on Nonenhanced Computed Tomography After Ischemic Stroke. Stroke. 2023. PMID: 36601950. doi:10.1161/STROKEAHA.122.041241

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。