无灌注成像的急性卒中患者灌注缺损的评估
本研究开发了NIH-FHV评分量化FLAIR高信号血管征,并在101例卒中患者中与灌注加权成像对比。结果显示该评分与灌注缺损体积强相关(P<0.001;R²=0.32),联合DWI识别不匹配比≥1.8的曲线下面积为0.94,作者认为在无灌注成像时可能有助于判断不匹配,但需进一步研究验证。
要点
- NIH-FHV评分与PWI病灶体积强相关(P<0.001;R²=0.32)。
- NIH-FHV评分联合DWI识别不匹配比≥1.8的AUC为0.94。
- 无灌注成像时,该评分可能有助于判断临床相关的扩散-灌注不匹配。
核心结论
- NIH-FHV评分可估算PWI病灶体积,联合DWI在无灌注成像时可能有助于判断临床相关的扩散-灌注不匹配。
- 作者指出需进一步研究验证该方法。
研究设计与样本
- 开发NIH-FHV评分量化FLAIR高信号血管征,并应用于同时具有FLAIR和灌注成像的卒中患者MRI扫描。
- 共纳入101例患者进行分析,其中78%在PWI上检测到灌注缺损,平均病灶体积为47(±59)mL。
主要发现
- NIH-FHV评分与PWI病灶体积强相关(P<0.001;R²=0.32;β系数0.57)。
- NIH-FHV评分联合DWI病灶体积识别不匹配比≥1.8的ROC分析曲线下面积为0.94。
关键数值与推荐
- 不匹配比阈值:≥1.8。
- NIH-FHV评分与PWI病灶体积关联的统计值:P<0.001;R²=0.32;β系数0.57。
- 识别不匹配比≥1.8的AUC为0.94。
临床怎么用
- 作者认为,在无法进行灌注成像的情况下,NIH-FHV评分联合DWI可能有助于判断是否存在临床相关的扩散-灌注不匹配。
- 作者指出需进一步研究验证该方法。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Perfusion weighted imaging (PWI) is critical for determining whether stroke patients presenting in an extended time window are candidates for mechanical thrombectomy. However, PWI is not always available. Fluid-attenuated inversion recovery hyperintense vessels (FHVs) are seen in patients with a PWI lesion. We investigated whether a scale measuring the extent FHV could serve as a surrogate for PWI to determine eligibility for thrombectomy. METHODS: The National Institutes of Health (NIH) FHV score was developed to quantify the burden of FHV and applied to magnetic resonance imaging scans of stroke patients with fluid-attenuated inversion recovery and perfusion imaging. The NIH-FHV was combined with the diffusion weighted image volume to estimate the diffusion-perfusion mismatch ratio. Linear regression was used to compare PWI volumes and mismatch ratios with estimates from the NIH-FHV score. Receiver operating characteristic analysis was used to test the ability of the NIH-FHV score to identify a significant mismatch. RESULTS: There were 101 patients included in the analysis, of whom 78% had a perfusion deficit detected on PWI with a mean lesion volume of 47 (±59) mL. The NIH-FHV score was strongly associated with the PWI lesion volume (P<0.001; R2=0.32; β-coefficient, 0.57). When combined with diffusion weighted image lesion volume, receiver operating characteristic analysis testing the ability to detect a mismatch ratio ≥1.8 using the NIH-FHV score resulted in an area under the curve of 0.94. CONCLUSIONS: The NIH-FHV score provides an estimate of the PWI lesion volume and, when combined with diffusion weighted imaging, may be helpful when trying to determine whether there is a clinically relevant diffusion-perfusion mismatch in situations where perfusion imaging is not available. Further studies are needed to validate this approach.
引用
- Reyes D, Simpkins AN, Hitomi E, et al. Estimating Perfusion Deficits in Acute Stroke Patients Without Perfusion Imaging. Stroke. 2022. PMID: 35866426. doi:10.1161/STROKEAHA.121.038101
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。