癫痫中电磁源成像与血流动力学反应的临床产出:用颅内数据验证
研究纳入17例耐药性癫痫患者,将EEG/MEG源成像(EMSI)与EEG/fMRI反应转换为SEEG通道空间,定量比较其与主要刺激区和发作起始区的空间重叠及预测术后结局的价值。EEG/MEG与EEG/fMRI均能准确定位致痫区,前者对主要刺激区更准确,后者对发作起始区更敏感,二者互补可指导SEEG植入和手术候选选择。
要点
- EEG/MEG源成像与主要刺激区的平均空间重叠为0.71,与发作起始区为0.65。
- EEG/fMRI反应与主要刺激区的平均空间重叠为0.57,与发作起始区为0.62。
- EEG/MEG正确预测15例中12例(80%)的手术结局,EEG/fMRI正确预测11例中6例(54%)。
核心结论
- EEG/MEG和EEG/fMRI均能准确定位发作起始区和主要刺激区,前者对主要刺激区更准确,后者对发作起始区更敏感,二者提供互补定位信息。
研究设计与样本
- 研究纳入17例在蒙特利尔神经病学研究所和医院癫痫服务处接受EEG/MEG、EEG/fMRI及后续SEEG的耐药性癫痫患者。
- 采用新方法将EMSI结果转换为SEEG电位(EMSIe-SEEG),并将最显著fMRI反应投射到SEEG通道(fMRIp-SEEG),在SEEG通道空间内量化多模态一致性。
主要发现
- EMSIe-SEEG与主要刺激区和发作起始区的平均空间重叠分别为0.71和0.65。
- fMRIp-SEEG与主要刺激区和发作起始区的平均空间重叠分别为0.57和0.62。
- EMSIe-SEEG与主要刺激区良好空间重叠与最大EMSIe-SEEG触点至尖峰最大振幅通道距离较小相关(中位距离14 mm)。
- fMRIp-SEEG与发作起始区良好空间重叠与最大fMRIp-SEEG触点至尖峰起始和发作核心通道距离较小相关(中位距离分别为10 mm和5 mm)。
- EEG/MEG正确预测15例中12例(80%)的手术结局,EEG/fMRI正确预测11例中6例(54%)的手术结局。
关键数值与推荐
- 空间重叠与主要刺激区/发作起始区(AUCPIZ、AUCSOZ)通过受试者工作特征曲线下面积(AUC)评估。
- AUC表示随机选取的活跃触点位于空间参考内时振幅高于参考外的概率。
临床怎么用
- EEG/MEG和EEG/fMRI提供互补定位,可帮助指导SEEG植入和选择合适的手术候选者。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVES: Accurate delineation of the seizure-onset zone (SOZ) in focal drug-resistant epilepsy often requires stereo-EEG (SEEG) recordings. Our aims were to propose a truly objective and quantitative comparison between EEG/magnetoencephalography (MEG) source imaging (EMSI), EEG/fMRI responses for similar spikes with primary irritative zone (PIZ) and SOZ defined by SEEG and to evaluate the value of EMSI and EEG/fMRI to predict postsurgical outcome. METHODS: We identified patients with drug-resistant epilepsy who underwent EEG/MEG, EEG/fMRI, and subsequent SEEG at the Epilepsy Service from the Montreal Neurological Institute and Hospital. We quantified multimodal concordance within the SEEG channel space as spatial overlap with PIZ/SOZ and distances to the spike-onset, spike maximum amplitude and seizure core intracerebral channels by applying a new methodology consisting of converting EMSI results into SEEG electrical potentials (EMSIe-SEEG) and projecting the most significant fMRI response on the SEEG channels (fMRIp-SEEG). Spatial overlaps with PIZ/SOZ (AUCPIZ, AUCSOZ) were assessed by using the area under the receiver operating characteristic curve (AUC). Here, AUC represents the probability that a randomly picked active contact exhibited higher amplitude when located inside the spatial reference than outside. RESULTS: Seventeen patients were included. Mean spatial overlaps with the PIZ and SOZ were 0.71 and 0.65 for EMSIe-SEEG and 0.57 and 0.62 for fMRIp-SEEG. Good EMSIe-SEEG spatial overlap with the PIZ was associated with smaller distance from the maximum EMSIe-SEEG contact to the spike maximum amplitude channel (median distance 14 mm). Conversely, good fMRIp-SEEG spatial overlap with the SOZ was associated with smaller distances from the maximum fMRIp-SEEG contact to the spike-onset and seizure core channels (median distances 10 and 5 mm, respectively). Surgical outcomes were correctly predicted by EEG/MEG in 12 of 15 (80%) patients and EEG/fMRI in 6 of 11(54%) patients. DISCUSSION: With the use of a unique quantitative approach estimating EMSI and fMRI results in the reference SEEG channel space, EEG/MEG and EEG/fMRI accurately localized the SOZ and the PIZ. Precisely, EEG/MEG more accurately localized the PIZ, whereas EEG/fMRI was more sensitive to the SOZ. Both neuroimaging techniques provide complementary localization that can help guide SEEG implantation and select good candidates for surgery.
引用
- Abdallah C, Hedrich T, Koupparis A, et al. Clinical Yield of Electromagnetic Source Imaging and Hemodynamic Responses in Epilepsy: Validation With Intracerebral Data. Neurology. 2022. PMID: 35473762. doi:10.1212/WNL.0000000000200337
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。