文献速递脑血管病

磁共振指纹动脉自旋标记同时血流动力学与结构成像对缺血性卒中的评估

Simultaneous Hemodynamic and Structural Imaging of Ischemic Stroke With Magnetic Resonance Fingerprinting Arterial Spin Labeling.
PubMed 文献 · Stroke · 2022-03-16

研究纳入34例缺血性卒中患者,在3T磁共振上比较磁共振指纹动脉自旋标记(MRF-ASL)与标准单延迟伪连续ASL,评估MRF-ASL检测血流动力学与结构损伤及预测神经功能缺损与残疾的效用。结果显示病灶区较对侧正常区脑血流量(CBF)降低、动脉到达时间(BAT)与组织T1延长,MRF-ASL参数与NIHSS评分及改良Rankin量表相关,且多参数分类卒中体素的曲线下面积高于标准ASL。

要点

  • MRF-ASL单次扫描<4分钟可同时获得CBF、BAT与组织T1图。
  • 病灶区较对侧正常区CBF降低、BAT与T1延长,差异有统计学意义。
  • MRF-ASL参数与NIHSS及改良Rankin量表相关,多参数分类体素的曲线下面积高于标准ASL。

核心结论

  • MRF-ASL可能为缺血性卒中提供一种定量血流动力学与结构成像的新方法。

研究设计与样本

  • 共34例缺血性卒中患者,在3T磁共振上完成MRF-ASL、标准单延迟伪连续ASL、T2加权与扩散磁共振成像。
  • 手动勾画病灶与对侧正常组织感兴趣区,量化CBF(两种不同隔室模型)、BAT与组织T1参数。
  • 采用横断面线性回归分析MRF-ASL参数与NIHSS及改良Rankin量表的关系,并用受试者工作特征分析评估MRF-ASL分类卒中病灶体素的效用。

主要发现

  • 病灶区较对侧正常感兴趣区表现为CBF1-隔室更低(P<0.001)、CBF2-隔室更低(P<0.001)、BAT更长(P=0.002)、T1更长(P<0.001)。
  • 急性期NIHSS评分与病灶-正常差值CBF1-隔室,diff(β=-0.11,P=0.008)、CBF2-隔室,diff(β=-0.16,P=0.003)及T1,diff(β=0.008,P=0.001)呈强关联。
  • MRF-ASL参数也可预测后期测量的NIHSS评分与改良Rankin量表,但关联程度较弱;在急性/亚急性期采集MRF-ASL数据时这些关联趋于更强。
  • 与标准伪连续ASL相比,MRF-ASL的多参数能力在卒中体素分类的受试者工作特征分析中给出更高的曲线下面积值。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Perfusion and structural imaging play an important role in ischemic stroke. Magnetic resonance fingerprinting (MRF) arterial spin labeling (ASL) is a novel noninvasive method of ASL perfusion that allows simultaneous estimation of cerebral blood flow (CBF), bolus arrival time (BAT), and tissue T1 map in a single scan of <4 minutes. Here, we evaluated the utility of MRF-ASL in patients with ischemic stroke in terms of detecting hemodynamic and structural damage and predicting neurological deficits and disability. METHODS: A total of 34 patients were scanned on 3T magnetic resonance imaging. MRF-ASL, standard single-delay pseudo-continuous ASL, T2-weighted, and diffusion magnetic resonance imaging were performed. Regions of interest of lesion and contralateral normal tissues were manually delineated. CBF (with 2 different compartmental models), BAT, and tissue T1 parameters were quantified. Cross-sectional linear regression analyses were performed to examine the relationship between MRF-ASL parameters and National Institutes of Health Stroke Scale (NIHSS) and modified Rankin Scale. Receiver operating characteristic analyses were performed to determine the utility of MRF-ASL in the classification of stroke lesion voxels. RESULTS: MRF-ASL derived parameters revealed a significant difference between stroke lesion and contralateral normal regions of interest, in that lesion regions manifested a lower CBF1-compartment (P<0.001), lower CBF2-compartment (P<0.001), longer BAT (P=0.002), and longer T1 (P<0.001) compared with normal regions of interest. NIHSS scores at acute stage revealed a strong association with lesion-normal differences in CBF1-compartment,diff (β=-0.11, P=0.008), CBF2-compartment,diff (β=-0.16, P=0.003), and T1,diff (β=0.008, P=0.001). MRF-ASL parameters were also predictive of NIHSS score and modified Rankin Scale scale measured at a later stage, although the degree of the associations was weaker. These associations tended to be even stronger when the MRF-ASL data were acquired at the acute/subacute stage. Compared with standard pseudo-continuous ASL, the multiparametric capability of MRF-ASL yielded higher area under curve values in the receiver operating characteristic analyses of stroke voxel classifications. CONCLUSIONS: MRF-ASL may provide a new approach for quantitative hemodynamic and structural imaging in ischemic stroke.

来源:Stroke,查看原文。版权归原作者所有。

引用

  1. Fan H, Su P, Lin DDM, et al. Simultaneous Hemodynamic and Structural Imaging of Ischemic Stroke With Magnetic Resonance Fingerprinting Arterial Spin Labeling. Stroke. 2022. PMID: 35291820. doi:10.1161/STROKEAHA.121.037066

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。