利用先进影像序列实现脑深部电刺激的个体化
本研究利用快速灰质获取T1反转恢复(FGATIR)序列识别丘脑低信号区,回顾性分析65例特发性震颤脑深部电刺激(DBS)患者,评估该低信号区预测临床结局的能力,发现其与震颤改善及已知热点距离相关,个体化解剖变异后预测力提高。
要点
- FGATIR序列识别的丘脑低信号区构成齿状核-红核-丘脑束终末部分。
- DBS刺激体积与低信号区重叠与震颤改善相关(R2=0.16,p=0.017)。
- 校正个体解剖变异后,低信号区预测力提高(R2=0.37,p=0.002)。
核心结论
- 本研究提出并验证一种源自FGATIR序列的新型影像标志物,有潜力用于特发性震颤DBS靶点选择与程控的个体化。
研究设计与样本
- 回顾性分析65例(26例女性,平均年龄69.1±12.7岁)接受DBS治疗的特发性震颤患者,使用FGATIR序列识别丘脑低信号区,并通过刺激体积建模和体素映射评估其预测临床结局的能力。
主要发现
- 解剖学特征提示所识别的低信号区构成齿状核-红核-丘脑束的终末部分。
- 标准空间中DBS刺激体积与低信号区的重叠与震颤改善显著相关(R2=0.16,p=0.017),与既往文献报道热点的距离也显著相关(R2=0.49,p=7.9e-4)。
- 其他解剖图谱结构解释的方差较小。
- 校正个体神经解剖变异后,低信号区的预测力进一步提高(R2=0.37,p=0.002)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: With a growing appreciation for interindividual anatomical variability and patient-specific brain connectivity, advanced imaging sequences offer the opportunity to directly visualize anatomical targets for deep brain stimulation (DBS). The lack of quantitative evidence demonstrating their clinical utility, however, has hindered their broad implementation in clinical practice. METHODS: Using fast gray matter acquisition T1 inversion recovery (FGATIR) sequences, the present study identified a thalamic hypointensity that holds promise as a visual marker in DBS. To validate the clinical utility of the identified hypointensity, we retrospectively analyzed 65 patients (26 female, mean age = 69.1 ± 12.7 years) who underwent DBS in the treatment of essential tremor. We characterized its neuroanatomical substrates and evaluated the hypointensity's ability to predict clinical outcome using stimulation volume modeling and voxelwise mapping. Finally, we determined whether the hypointensity marker could predict symptom improvement on a patient-specific level. RESULTS: Anatomical characterization suggested that the identified hypointensity constituted the terminal part of the dentatorubrothalamic tract. Overlap between DBS stimulation volumes and the hypointensity in standard space significantly correlated with tremor improvement (R2 = 0.16, p = 0.017) and distance to hotspots previously reported in the literature (R2 = 0.49, p = 7.9e-4). In contrast, the amount of variance explained by other anatomical atlas structures was reduced. When accounting for interindividual neuroanatomical variability, the predictive power of the hypointensity increased further (R2 = 0.37, p = 0.002). INTERPRETATION: Our findings introduce and validate a novel imaging-based marker attainable from FGATIR sequences that has the potential to personalize and inform targeting and programming in DBS for essential tremor. ANN NEUROL 2022;91:613-628.
引用
- Neudorfer C, Kroneberg D, Al-Fatly B, et al. Personalizing Deep Brain Stimulation Using Advanced Imaging Sequences. Ann Neurol. 2022. PMID: 35165921. doi:10.1002/ana.26326
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。