文献速递脑血管病

弥散加权成像与液体衰减反转恢复定量预测发病时间不明的缺血性卒中DWI-FLAIR不匹配状态

Diffusion-Weighted Imaging and Fluid-Attenuated Inversion Recovery Quantification to Predict Diffusion-Weighted Imaging-Fluid-Attenuated Inversion Recovery Mismatch Status in Ischemic Stroke With Unknown Onset.
PubMed 文献 · Stroke · 2022-02-02

研究基于WAKE-UP试验筛查患者,回顾性分析相对DWI信号强度(rDWI SI)和FLAIR信号强度(rFLAIR SI)预测DWI-FLAIR不匹配状态。rFLAIR SI均值切点1.09和rDWI SI四分位距切点0.47预测不匹配的敏感度与特异度分别为77%和67%、76%和72%,与视觉评估的一致性仅为中等(κ=0.44和0.48)。作者认为定量与定性方法的一致性可能不足以提倡用DWI或FLAIR定量替代视觉评估。

要点

  • rFLAIR SI均值切点1.09预测DWI-FLAIR不匹配的敏感度77%、特异度67%。
  • rDWI SI四分位距切点0.47预测不匹配的敏感度76%、特异度72%。
  • 定量参数与视觉评估一致性仅为中等(κ=0.44和0.48),可能不足以替代视觉评估。

核心结论

  • 定量与定性方法之间的一致性可能不足以提倡将DWI或FLAIR定量作为视觉评估的替代方案。

研究设计与样本

  • 基于WAKE-UP试验筛查患者的回顾性研究,分析相对DWI信号强度(rDWI SI)和FLAIR信号强度(rFLAIR SI)。

主要发现

  • rFLAIR SI分析中213/369例存在DWI-FLAIR不匹配,rDWI SI分析中241/421例存在不匹配。
  • rFLAIR SI均值切点1.09预测不匹配的敏感度77%(95%CI 71%-83%)、特异度67%(95%CI 59%-74%)。
  • rDWI SI四分位距切点0.47预测不匹配的敏感度76%(95%CI 70%-81%)、特异度72%(95%CI 65%-79%)。
  • 两参数与DWI-FLAIR不匹配的一致性均为中等:rFLAIR为73%(κ=0.44,95%CI 0.35-0.54),rDWI为74%(κ=0.48,95%CI 0.39-0.56)。
  • rDWI SI四分位距(n=188)而非rFLAIR SI均值(n=172)是优良功能结局的独立预测因子(每增加0.1单位OR 0.67,95%CI 0.51-0.89,P=0.01)。

关键数值与推荐

  • rFLAIR SI均值切点1.09、rDWI SI四分位距切点0.47为预测DWI-FLAIR不匹配的最佳切点。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Visual rating of diffusion-weighted imaging (DWI)-fluid-attenuated inversion recovery (FLAIR) mismatch can be challenging. We evaluated quantification of DWI and FLAIR to predict DWI-FLAIR mismatch status in ischemic stroke. METHODS: In screened patients from the WAKE-UP trial (Efficacy and Safety of Magnetic Resonance Imaging-Based Thrombolysis in Wake-Up Stroke), we retrospectively studied relative DWI (rDWI SI) and FLAIR signal intensity (rFLAIR SI). We defined the optimal mean rFLAIR SI and interquartile range of the rDWI SI in the DWI lesion to predict DWI-FLAIR mismatch status. We investigated agreement between each quantitative parameter and the DWI-FLAIR mismatch and the association between both quantitative parameters. We evaluated the predictive value of the quantitative parameters for excellent functional outcome by logistic regression, adjusted for DWI lesion volume, treatment, age, and National Institutes of Health Stroke Scale score. RESULTS: In the rFLAIR and rDWI SI analysis, 213/369 and 241/421 subjects respectively had a DWI-FLAIR mismatch. A mean rFLAIR SI cutoff of 1.09 and interquartile range rDWI SI cutoff of 0.47 were optimal to predict the DWI-FLAIR mismatch with a sensitivity and specificity of 77% (95% CI, 71%-83%) and 67% (95% CI, 59%-74%), and 76% (95% CI, 70%-81%) and 72% (95% CI, 65%-79%), respectively. For both quantitative parameters, agreement with the DWI-FLAIR mismatch was fair (73%, κ=0.44 [95% CI, 0.35-0.54] for rFLAIR and 74%, κ=0.48 [95% CI, 0.39-0.56] for rDWI). Both quantitative parameters correlated moderately (Pearson R=0.54 [95% CI, 0.46-0.61]; P<0.001, n=367). The interquartile range rDWI SI (n=188), but not the mean rFLAIR SI (n=172), was an independent predictor of excellent functional outcome (odds ratio, 0.67 per 0.1 unit increase of interquartile range rDWI SI, 95% CI, 0.51-0.89, P=0.01). CONCLUSIONS: Agreement between the quantitative and qualitative approach may be insufficient to advocate DWI or FLAIR quantification as alternative for visual rating.

来源:Stroke,查看原文。版权归原作者所有。

引用

  1. Scheldeman L, Wouters A, Dupont P, et al. Diffusion-Weighted Imaging and Fluid-Attenuated Inversion Recovery Quantification to Predict Diffusion-Weighted Imaging-Fluid-Attenuated Inversion Recovery Mismatch Status in Ischemic Stroke With Unknown Onset. Stroke. 2022. PMID: 35105179. doi:10.1161/STROKEAHA.121.036871

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。