三维超声体积与传统超声直径变化均是内漏的良好标志物
本研究为单中心诊断准确性研究,纳入92例拟行血管内动脉瘤修复术患者,术前及术后1、6、12、24个月用CTA、传统超声和三维超声测量瘤囊直径与体积。结果显示传统超声直径与CT直径相关性好(r=0.9),三维超声体积与CTA直径及三维CT体积相关性均为r=0.8,直径与体积变化诊断内漏的AUC均优异,但三维超声体积未增加诊断信息。
要点
- 传统超声直径与CT直径相关性好,可作为内漏随访的简单指标。
- 三维超声体积与CTA直径及三维CT体积相关性均为r=0.8。
- 直径与体积变化诊断内漏的AUC均优异,但三维超声未增加额外信息。
核心结论
- 传统超声直径测量与三维超声体积变化均可作为内漏的标志物,但三维超声体积未提供额外诊断信息。
- II型内漏可安全地通过传统超声简单直径测量进行随访。
研究设计与样本
- 单中心诊断准确性研究,前瞻性连续纳入92例拟行血管内动脉瘤修复术患者(2013-2016年)。
- 术前及术后1、6、12、24个月用CTA、传统超声和三维超声测量瘤囊直径与体积。
主要发现
- 传统超声直径与CT直径相关性好(r=0.9,P<.05,n=347),Bland-Altman一致性上限+0.5 cm、下限-0.8 cm,平均差异-0.13 cm±0.36 cm。
- 三维超声体积与CTA直径相关性r=0.8(P<.05,n=347),与三维CT体积相关性r=0.8(P<.05,n=155)。
- 导致再干预的直径与体积变化在24个月随访时ROC分析最准确,AUC百分比变化:二维超声0.98、三维超声0.97、二维CT 0.97。
关键数值与推荐
- 传统超声直径与CT直径相关性r=0.9(P<.05,n=347)。
- 三维超声体积与CTA直径相关性r=0.8(P<.05,n=347),与三维CT体积相关性r=0.8(P<.05,n=155)。
- 24个月随访时导致再干预的直径与体积变化AUC:二维超声0.98、三维超声0.97、二维CT 0.97。
临床怎么用
- II型内漏随访可采用传统超声简单直径测量,无需常规三维超声体积评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The main disadvantages of computed tomography angiography (CTA) in follow-up after endovascular aneurysm repair are the risks of contrast-induced renal impairment and radiation-induced cancer. Three-dimensional ultrasound is a new technique for volume estimation of the aneurysm sac. Some studies have reported promising results. The aim of this study was to evaluate the accuracy and precision of three-dimensional ultrasound aneurysm sac-volume estimates, and to explore whether volume and/or diameter changes on ultrasound can be used as markers of endoleak. METHODS: A single-center diagnostic accuracy study was performed. A total of 92 patients planned for endovascular aneurysm repair were prospectively and consecutively enrolled (2013-2016). Aneurysm sac diameter and volume were measured using CTA, conventional ultrasound, and three-dimensional ultrasound preoperatively and 1, 6, 12, and 24 months postoperatively. Three-dimensional ultrasound was performed with a commercially available electromechanical transducer. Patients with endoleak were observed 5 years after endovascular aneurysm repair. RESULTS: A total of 79 men and 13 women were included. Mean age was 74 years (57-92 years). Median follow-up was 24 months. Endoleak cases were observed for up to 55 months. Diameter measurements on conventional ultrasound correlated well with CT diameters (r = 0.9, P < .05, n = 347), and Bland-Altman analyses showed an upper limit of agreement of +0.5 cm and a lower limit of agreement of -0.8 cm. The mean difference was -0.13 cm ± 0.36 cm. Three-dimensional ultrasound volumes had a correlation with CTA diameters of r = 0.8 (P < .05, n = 347) and with three-dimensional CT volumes of r = 0.8 (P < .05, n = 155). Receiver operating characteristic analyses showed that the diameter and volume changes that led to reintervention were most accurate at 24-month follow-up, with area-under-the-curve percentage changes of 0.98 (two-dimensional ultrasound), 0.97 (three-dimensional ultrasound), and 0.97 (two-dimensional CT). DISCUSSION: Both diameter and volume changes can be used as markers for endoleak with excellent areas under the curve on receiver operating characteristic analyses. However, three-dimensional ultrasound volumes did not add any further diagnostic information. Conventional 2D diameter measurements were as accurate as volume changes as markers of endoleak. CONCLUSIONS: Type II endoleaks can safely be followed up using a simple diameter measurement on conventional ultrasound.