文献速递主动脉疾病

支架主动固定与放大率对肾下腹主动脉瘤腔内修复后瘤颈扩张的影响

Effect of Stent-Graft Active Fixation and Oversizing on Aortic Neck Dilation After Endovascular Aneurysm Exclusion For Infrarenal Aortic Aneurysm.
PubMed 文献 · Ann Vasc Surg · 2021-10-14

该回顾性研究分析了154例肾下腹主动脉瘤腔内修复(EVAR)患者,评估支架放大率和固定类型对主动脉颈扩张的影响。结果显示,主动肾上固定组肾上主动脉直径在4年随访时显著增加(1.86 mm,CI:0.65-3.06,P=0.0026),而放大率<10%对肾上主动脉影响较小(0.41 mm vs. 3.26 mm,P<0.001)。结论提示肾下主动固定和放大率<10%对瘤颈扩张影响最小。

要点

  • 主动肾上固定与肾上主动脉直径显著增加相关(P=0.0026)。
  • 放大率<10%对肾上主动脉扩张影响小于>15%(P<0.001)。
  • 肾下主动固定和放大率<10%对瘤颈扩张影响最小。

核心结论

  • 肾下主动固定支架和放大率<10%对主动脉颈扩张影响最小。

研究设计与样本

  • 回顾性研究,2006-2015年单中心EVAR病例,收集432例,最终分析154例。

主要发现

  • 主动肾上固定组4年肾上主动脉直径变化1.86 mm(CI:0.65-3.06),仅该组显著增加(P=0.0026)。
  • 放大率<10%组4年肾上主动脉直径变化0.41 mm(CI:-0.31至-1.14),>15%组3.26 mm(CI:1.63-4.88),P<0.001。
  • 肾下主动脉直径变化:<10%组3.01 mm(CI:2.18-3.83),10-15%组5.95 mm(CI:3.26-8.64),>15%组5.05 mm(CI:3.41-6.69)。

关键数值与推荐

  • 主动肾上固定组肾上主动脉直径变化1.86 mm(CI:0.65-3.06),主动肾下固定组0.22 mm(CI:-0.67至-1.11),被动肾上固定组1.52 mm(CI:-0.11至-3.15)。
  • 放大率<10%组肾上主动脉直径变化0.41 mm(CI:-0.31至-1.14),>15%组3.26 mm(CI:1.63-4.88),P<0.001。

临床怎么用

  • EVAR术中可考虑选择肾下主动固定支架和放大率<10%以减少瘤颈扩张。

局限性

  • 回顾性单中心研究,样本量有限(分析154例),随访时间4年。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Aortic neck dilation post endovascular aneurysm repair (EVAR) has been implicated in the long-term development of endoleak and the subsequent re-intervention. Optimal endograft sizing is a vital aspect to successful repair. This study looked at percentage of graft oversizing as well as type of fixation on aortic neck dilation. METHODS: We retrospectively evaluated all EVARs completed at Loyola's University from 2006 to 2015 after IRB approval. Patients without follow-up scans within a year were excluded. We collected demographics, comorbidities, graft type, size, aortic neck diameter, maximum sac size diameters from the pre-operative and follow-up scans. We reviewed and collected data on 432 patients but analyzed 154. We measured the largest aortic diameter on axial images 1 cm above and 1 cm below the lowest renal artery. Change in supra and infrarenal aortic measurements were evaluated by calculating the mm difference from each scan compared to the pre-operative scan. Linear mixed effects models were used to estimate patients' mean differences over time. RESULTS: We compared three groups of neck fixation grafts. Those with active suprarenal fixation had a significant change in suprarenal aortic diameter at four-year follow-up (1.86 mm, CI:0.65-3.06), compared to those with active infrarenal (0.22 mm, CI: -0.67 to -1.11) or passive suprarenal fixation (1.52 mm, CI: -0.11 to -3.15) (Fig. 1). Those with active suprarenal fixation were the only ones to have significant increase in suprarenal aortic diameter (P = 0.0026). Degree of oversizing was also divided into three groups. Oversizing by <10% had less impact on the suprarenal aorta than >15% oversizing at 4 years (0.41 mm, CI: -0.31 to -1.14 vs. 3.26 mm, CI: 1.63-4.88, P < 0.001) (Fig. 2). Oversizing had a more pronounced effect on the infrarenal aorta: 3.01 mm, CI: 2.18-3.83; 5.95 mm, CI: 3.26-8.64; and 5.05 mm, CI: 3.41-6.69 for <10%, 10-15%, and >15% oversizing at four years, respectively. CONCLUSION: Stent-grafts with active fixation below the renal arteries as well as oversizing by <10% seem to have the least effect on aortic neck dilation over time. These factors should be considered when performing EVARs, as aortic neck dilation could lead to endoleak and need for further intervention. Further research defining the optimal stent-graft type, self-expanding versus balloon expandable, type of fixation and degree of oversizing.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Malach L, Tehrani N, Kolachina S, et al. Effect of Stent-Graft Active Fixation and Oversizing on Aortic Neck Dilation After Endovascular Aneurysm Exclusion For Infrarenal Aortic Aneurysm. Ann Vasc Surg. 2021. PMID: 34656723. doi:10.1016/j.avsg.2021.08.026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。