利用开源CFD分析主动脉夹层血流动力学参数差异:健康与Stanford A/B型对比
结果显示,在真假腔之间的内膜片高WSS区域,流速与WSS高度相关;多数Stanford A型夹层在收缩期出现超过38 Pa的高WSS,提示A型夹层动脉壁在搏动血流下更易受损。作者认为,CFD估算局部高WSS区域可能有助于决定是否使用覆膜支架治疗A型或B型夹层以预防破裂。
要点
- 开源CFD可基于CT图像评估主动脉夹层血流动力学参数。
- Stanford A型夹层收缩期多见WSS超过38 Pa,提示壁损伤风险高。
- 局部高WSS区域可能辅助支架治疗决策。
核心结论
- 使用开源CFD估算局部高WSS区域可能有助于决定对A型或B型夹层行覆膜支架治疗以预防潜在破裂。
研究设计与样本
- 本研究为数值模拟研究,使用8例主动脉夹层(Stanford A型和B型)及3例健康主动脉的CT图像进行三维几何分割,并在开源CFD软件OpenFOAM中模拟 pulsatile 血流。
主要发现
- 计算并可视化了主动脉及假腔内的压力分布、壁面剪切应力(WSS)和流速流线。
- 在真假腔之间内膜片的高WSS区域,流速与WSS高度相关。
- 研究中多数Stanford A型夹层在收缩期显示WSS超过38 Pa。
关键数值与推荐
- Stanford A型夹层在收缩期WSS超过38 Pa提示动脉壁更易在搏动血流下受损。
临床怎么用
- CFD估算的局部高WSS区域可作为决策A型或B型夹层是否行覆膜支架治疗的参考信息。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The objective of this study was to develop a method to evaluate the effects of an aortic dissection on hemodynamic parameters by conducting a comparison with that of a healthy (nondissected) aorta. Open-source software will be implemented, no proprietary software/application will be used to ensure accessorily and repeatability, in all the data analysis and processing. Computed tomography (CT) images of aortic dissection are used for the model geometry segmentation. Boundary conditions from literature are implemented to computational fluid dynamics (CFD) to analyze the hemodynamic parameters. METHODS: A numerical simulation model was created by obtaining accurate 3-dimensional geometries of aortae from CT images. In this study, CT images of 8 cases of aortic dissection (Stanford type-A and type-B) and 3 cases of healthy aortae are used for the actual aorta model geometry segmentation. These models were exported into an open-source CFD software, OpenFOAM, where a simplified pulsating flow was simulated by controlling the flow pressure. Ten cycles of the pulsatile flow (0.50 sec/cycle) conditions, totaling 5 sec, were calculated. RESULTS: The pressure distribution, wall shear stress (WSS) and flow velocity streamlines within the aorta and the false lumen were calculated and visualized. It was found that the flow velocity and WSS had a high correlation in high WSS areas of the intermittent layer between the true and false lumen. Most of the Stanford type-A dissections in the study showed high WSS, over 38 Pa, at the systole phase. This indicates that the arterial walls in type-A dissections are more likely to be damaged with pulsatile flow. CONCLUSIONS: Using CFD to estimate localized high WSS areas may help in deciding to treat a type-A or B dissection with a stent graft to prevent a potential rupture.
引用
- Takeda R, Sato F, Yokoyama H, et al. Investigations into the Potential of Using Open Source CFD to Analyze the Differences in Hemodynamic Parameters for Aortic Dissections (Healthy versus Stanford Type A and B). Ann Vasc Surg. 2021. PMID: 34648855. doi:10.1016/j.avsg.2021.08.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。