腹主动脉瘤应力分析在附壁血栓患者中不能准确预测破裂位置
该研究纳入5例腹主动脉瘤患者,比较破裂前6个月内与破裂时两次CT的有限元应力分析,采用「壁」模型(无附壁血栓)和「血栓」模型(含附壁血栓)。结果显示破裂部位与最大应力位置仅1例(唯一无附壁血栓者)一致,破裂阈值随附壁血栓存在而显著变化,应力值个体差异大。
要点
- 附壁血栓存在时,破裂部位与最大应力位置不一致。
- 破裂阈值因附壁血栓而显著变化,个体差异大。
- 无附壁血栓患者破裂部位与最大应力位置一致。
核心结论
- 破裂部位与最大应力位置仅在1例无附壁血栓患者中一致。
- 破裂阈值因附壁血栓存在而显著变化,个体差异大。
研究设计与样本
- 纳入5例腹主动脉瘤破裂患者,均有破裂前6个月内和破裂时两次CT。
- 对两次CT均行三维几何重建、网格划分和有限元应力分析。
- 采用「壁」模型(无附壁血栓)和「血栓」模型(含附壁血栓)两种建模场景。
主要发现
- 破裂前与破裂时CT平均间隔44天(22-97)。
- 「壁」模型最大应力中位数:破裂前0.817 MPa(0.555-1.295),破裂时1.160 MPa(0.633-1.625)。
- 「血栓」模型最大应力中位数:破裂前0.365 MPa(0.291-0.753),破裂时0.390 MPa(0.343-0.819)。
- 破裂部位与最大应力位置仅1例一致,该例为唯一无附壁血栓患者。
临床怎么用
- 对附壁血栓患者,不宜仅依据最大应力位置预测破裂部位。
- 评估破裂风险时需考虑附壁血栓对破裂阈值的影响。
局限性
- 样本量仅5例,结论外推受限。
- 仅1例无附壁血栓,无法充分比较有无血栓的差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: A biomechanical approach to the rupture risk of an abdominal aortic aneurysm could be a solution to ensure a personalized estimate of this risk. It is still difficult to know in what conditions, the assumptions made by biomechanics, are valid. The objective of this work was to determine the individual biomechanical rupture threshold and to assess the correlation between their rupture sites and the locations of their maximum stress comparing two computed tomography scan (CT) before and at time of rupture. METHODS: We included 5 patients who had undergone two CT; one within the last 6 months period before rupture and a second CT scan just before the surgical procedure for the rupture. All DICOM data, both pre- and rupture, were processed following the same following steps: generation of a 3D geometry of the abdominal aortic aneurysm, meshing and computational stress analysis using the finite element method. We used two different modelling scenarios to study the distribution of the stresses, a "wall" model without intraluminal thrombus (ILT) and a "thrombus" model with ILT. RESULTS: The average time between the pre-rupture and rupture CT scans was 44 days (22-97). The median of the maximum stresses applied to the wall between the pre-rupture and rupture states were 0.817 MPa (0.555-1.295) and 1.160 MPa (0.633-1.625) for the "wall" model; and 0.365 MPa (0.291-0.753) and 0.390 MPa (0.343-0.819) for the "thrombus" model. There was an agreement between the site of rupture and the location of maximum stress for only 1 patient, who was the only patient without ILT. CONCLUSIONS: We observed a large variability of stress values at rupture sites between patients. The rupture threshold strongly varied between individuals depending on the intraluminal thrombus. The site of rupture did not correlate with the maximum stress except for 1 patient.
引用
- Lorandon F, Rinckenbach S, Settembre N, et al. Stress Analysis in AAA does not Predict Rupture Location Correctly in Patients with Intraluminal Thrombus. Ann Vasc Surg. 2021. PMID: 34648863. doi:10.1016/j.avsg.2021.08.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。