文献速递慢性静脉疾病

1910nm激光静脉内凝固术中使用裸尖与径向光纤的静脉及静脉周围组织形态学变化

Morphological changes of veins and perivenous tissues during endovenous laser coagulation using 2-μm laser radiation and various types of optical fibers.
PubMed 文献 · J Vasc Surg Venous Lymphat Disord · 2021-09-24

该研究在6只羊的22条浅静脉上实施1910nm波长静脉内激光凝固术(EVLC),比较裸尖光纤与径向光纤的组织学效应。裸尖光纤在20J/cm能量密度下对3-4mm静脉造成管壁穿孔和静脉周围结缔组织(PVCT)损伤,而径向光纤对3.9±0.5mm静脉未导致穿孔并减少管壁外热损伤。

要点

  • 裸尖光纤在20J/cm下对3-4mm静脉可致穿孔并损伤PVCT。
  • 径向光纤对3.9±0.5mm静脉未致穿孔,热损伤局限于425.7±22.0μm内。
  • 1910nm波长可在较低功率下完成EVLC。

核心结论

  • 裸尖光纤在穿孔投影处PVCT损伤血管距凝固管壁较远,对侧则因能量输出少而距离缩短。
  • 径向光纤使热能量均匀分布于管壁并损伤全层,同时最小化管壁外热损伤。

研究设计与样本

  • 在6只羊的22条浅静脉上实施EVLC。
  • 使用1910nm波长、最大输出功率10W的激光,比较裸尖光纤与径向光纤(含双环)。
  • 采用组织学和形态学方法分析。

主要发现

  • 裸尖光纤在20J/cm下对3-4mm静脉导致裂隙状或宽大管壁穿孔。
  • 宽穿孔投影处PVCT完全破坏;穿孔对侧残余管壁碎片与损伤小血管距离为257.7±23.6μm。
  • 穿孔附近热损伤半径增至2073.5±8.0μm。
  • 径向光纤对3.9±0.5mm静脉未致穿孔,PVCT小血管破坏距离为425.7±22.0μm。

临床怎么用

  • 了解1910nm激光及不同类型光纤的形态学效应有助于预测和减少并发症。
  • 径向光纤可均匀加热管壁并减少管壁外热损伤。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To determine the morphological changes in veins and perivenous tissues after endovenous laser coagulation (EVLC) using laser radiation with a wavelength of 1910 nm and different types of fibers (bare tip and radial). METHODS: The EVLC procedure was carried out on 22 surface veins of six sheep. The radiation source was a diode-pumped solid-state laser, which was based on a LiYF4:Tm crystal and had an emission wavelength of 1910 nm and a maximum output power of 10 W. Two types of optical fibers were used: (1) bare tip and (2) radial or radial with two rings. Histological and morphometric methods were used, and the statistical digital data were analyzed. RESULTS: The use of a linear endovenous energy density of 20 J/cm and optical bare fibers for veins with diameters of 3-4 mm resulted in a slit-shaped or wide venous wall perforation. A thermal effect was observed on the perivenous connective tissue (PVCT), which caused damage to its structures. Wide perforations were accompanied by complete destruction of the PVCT in the projection of the formed defect. The distance between the remaining vein wall fragment, located opposite to the perforation, and injured small vessels was 257.7 ± 23.6 μm. The radius of thermal damage increased to 2073.5 ± 8.0 μm near the vessel perforation. Using optical radial fibers for veins with diameters of 3.9 ± 0.5 mm did not lead to perforations. The destructive effect of the laser on small vessels of the PVCT extended to a distance of 425.7 ± 22.0 μm. CONCLUSIONS: Analysis of thermal vessel damage in perivenous tissue after EVLC with bare-tip fiber shows that in the projection of a wide perforation, the damaged vessels of the PVCT are located at a large distance from the coagulated vein wall. On the opposite side of the perforation, the distance from the coagulated vein wall to the damaged vessels of the PVCT is significantly reduced because of the minimal output of laser radiation energy through the poorly damaged part of the wall. Using an optical radial fiber facilitates the application of a uniform distribution of thermal energy to the vein wall and damage to all its layers; at the same time, it minimizes the thermal energy that extends beyond the vein wall and damages the surrounding tissue. CLINICAL RELEVANCE: The use of radiation with a wavelength of 1910 nm will make it possible to carry out endovenous laser coagulation of varicose veins at lower power values compared with radiation in the micron and one and a half micron regions of the spectrum. Understanding of morphological changes of veins and perivenous tissues after endovenous laser coagulation with 1910-nm laser radiation and different types of optical fibers (bare-tip, radial, radial 2ring) help predict possible complications and reduce their rate.

来源:J Vasc Surg Venous Lymphat Disord,查看原文。版权归原作者所有。

引用

  1. Artemov SA, Belyaev AN, Bushukina OS, et al. Morphological changes of veins and perivenous tissues during endovenous laser coagulation using 2-μm laser radiation and various types of optical fibers. J Vasc Surg Venous Lymphat Disord. 2021. PMID: 34506961. doi:10.1016/j.jvsv.2021.08.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。