血管内超声与血管造影评估股腘动脉参考血管直径的差异
本研究基于前瞻性多中心数据库,纳入1725例症状性外周动脉疾病患者的1967条肢体,接受IVUS辅助的股腘动脉腔内治疗。结果显示IVUS评估的参考血管直径显著大于造影评估(6.0±1.0 mm vs 5.0±1.0 mm,p<0.001),平均差值0.98 mm(95%CI 0.94-1.03 mm),48.8%的患者差值≥1 mm。小血管、双侧钙化、支架植入史与差值≥1 mm风险增加相关,慢性完全闭塞与之负相关。
要点
- IVUS评估的参考血管直径较造影平均大0.98 mm,近半数患者差值≥1 mm。
- 小血管、双侧钙化及支架植入史增加造影低估风险,慢性完全闭塞降低该风险。
- 在股腘动脉腔内治疗中,造影可能低估参考血管直径,IVUS可提供更精确测量。
核心结论
- IVUS评估的参考血管直径显著大于造影评估,约半数患者差值≥1 mm。
- 小血管、慢性完全闭塞、双侧钙化和支架植入史影响造影与IVUS的直径差异。
研究设计与样本
- 前瞻性多中心数据库分析,纳入1725例症状性外周动脉疾病患者的1967条肢体,接受IVUS辅助的股腘动脉腔内治疗。
主要发现
- IVUS评估的参考血管直径显著大于造影评估(6.0±1.0 mm vs 5.0±1.0 mm,p<0.001)。
- 平均差值(IVUS减造影)为0.98 mm(95%CI 0.94-1.03 mm)。
- 48.8%(95%CI 46.5%-51.0%)的患者差值≥1 mm。
- 多变量分析显示小血管、双侧钙化和支架植入史与差值≥1 mm风险增加显著相关,慢性完全闭塞与风险降低显著相关。
临床怎么用
- 在股腘动脉腔内治疗中,应意识到造影可能低估参考血管直径,IVUS可提供更精确的测量。
- 对于小血管、双侧钙化或支架植入史的患者,造影低估风险更高,可考虑使用IVUS指导。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Although reference vessel diameter (RVD) is conveniently measured by angiography during femoropopliteal (FP) endovascular therapy (EVT) in clinical practice, angiography will potentially underestimate RVD. On the other hand, intravascular ultrasound (IVUS) can measure RVD precisely. The aim of this study was to reveal the difference between angiography- and IVUS-assessed RVD in patients undergoing FP-EVT for symptomatic peripheral artery disease (PAD). METHODS: We analyzed a prospective and multicenter database including 1967 limbs of 1725 patients with symptomatic PAD undergoing IVUS-supported FP-EVT. The study outcome measure was the difference between IVUS- and angiography-assessed distal RVD (ΔRVD), calculated as angiography-assessed RVD subtracted from IVUS-assessed RVD. The clinically important difference was defined as 1 mm or larger. RESULTS: IVUS-assessed RVD was significantly larger than angiography-assessed RVD (6.0±1.0 mm vs 5.0±1.0 mm; p<0.001). Mean ΔRVD (IVUS- minus angiography-assessed RVD) was 0.98 mm (95% CI, 0.94-1.03 mm). ΔRVD was 1 mm or larger in 48.8% (46.5%-51.0%) of the whole population. Multivariate analysis demonstrated that small angiography-assessed RVD, angiography-assessed bilateral calcification, and history of stent implantation were significantly associated with an increasing risk of ΔRVD ≥1mm, whereas presence of chronic total occlusion (CTO) was significantly associated with a decreasing risk of ΔRVD ≥1 mm. CONCLUSION: The current study revealed the difference between angiography-assessed reference lumen diameter and IVUS-assessed reference EEM diameter of FP lesions. About half of population had ΔRVD ≥1 mm. IVUS-assessed RVD was more likely to be different by angiography in cases with small vessels, CTO, bilateral calcification, and history of stent implantation.
引用
- Iida O, Takahara M, Soga Y, et al. Vessel Diameter Evaluated by Intravascular Ultrasound Versus Angiography. J Endovasc Ther. 2021. PMID: 34569354. doi:10.1177/15266028211047946
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。