术中主动脉侧支弹簧圈栓塞预防2型内漏的EVAR中期结局
本研究评估了EVAR术中行主动脉侧支弹簧圈栓塞预防2型内漏的中期结果。纳入2015年6月前59例对照和之后79例弹簧圈组,栓塞所有内径>2.0mm的肠系膜下动脉和腰动脉。弹簧圈组2型内漏频率显著降低,5年免于瘤囊扩张率100% vs 65.2%,瘤囊缩小率更优。
要点
- EVAR术中栓塞内径>2.0mm的IMA和LA可降低2型内漏发生率
- IMA通畅使瘤囊扩张风险增加11倍,≥3条LA通畅增加4.9倍
- 弹簧圈组5年免于瘤囊扩张率100%,显著优于对照组65.2%
核心结论
- EVAR术中通过主动脉侧支弹簧圈栓塞使IMA闭塞且通畅LA数量≤2条时,可获得良好的中期结果。
研究设计与样本
- 单中心回顾性研究,2015年6月前59例EVAR未栓塞者为对照组,之后79例术中行主动脉侧支弹簧圈栓塞者为弹簧圈组。
主要发现
- 弹簧圈组IMA栓塞成功率96.4%,LA栓塞成功率74.5%。
- 2型内漏频率弹簧圈组显著低于对照组:术后7天1.3% vs 60.4%(P<0.0001),6个月2.1% vs 38.2%(P<0.0001)。
- 5年免于瘤囊扩张率弹簧圈组100%,对照组65.2%(P=0.002)。
- 瘤囊缩小率弹簧圈组更优:1年15.5% vs 2.0%,2年42.8% vs 6.3%,3年53.4% vs 17.8%(p=0.0007)。
- EVAR结束时IMA通畅者瘤囊扩张≥5mm风险增加11倍,≥3条LA通畅者增加4.9倍。
关键数值与推荐
- 自2015年6月起,对所有内径>2.0mm的通畅IMA和LA行弹簧圈栓塞;若≥4条LA通畅,则对内径≤2.0mm的LA也行栓塞。
临床怎么用
- EVAR术中可考虑对通畅的IMA和内径>2.0mm的LA行弹簧圈栓塞,以降低2型内漏和瘤囊扩张风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The midterm results of endovascular abdominal aortic aneurysm repair (EVAR) with aortic side branch coil embolization during EVAR was evaluated. METHODS: Our center began coil embolization for all patent inferior mesenteric artery (IMA) and lumbar artery (LA) with an inner diameter more than 2.0 mm during EVAR since June 2015. When four or more LA were patent, coil embolization for LA with inner diameter 2.0 mm or less was done. EVAR without aortic side branches coil embolization was performed for 59 patients prior to June 2015 (control group) and 79 patients underwent EVAR with coil embolization during EVAR (coil group). The success rate of coil embolization for IMA and LA was evaluated in coil group. The frequency of type 2 endoleak (T2EL), freedom from aneurysm sac expansion (5 mm or more) rate and the rate of the aneurysm sac shrinkage (10 mm or more) were compared between the coil and control groups. Additionally, multiple logistic regression analysis for all patients was conducted to analyze whether IMA patency and the number of patent lumbar artery at the end of EVAR were the risk factors of the aneurysm sac expansion of 5 mm or more. RESULTS: The success rate of IMA coil embolization was 96.4% and that of LA was 74.5%. Compared to the control group, the frequency of T2EL was significantly lower in coil group at 7 days (1.3% vs. 60.4%, P <0.0001) and at 6 months (2.1% vs 38.2%, P <0.0001) after EVAR. The freedom from aneurysm sac expansion rate was significantly better in the coil group at 5 years (100% in coil group and 65.2% in control group, P = 0.002). The rate of aneurysm sac shrinkage was significantly better in coil group (15.5% vs. 2.0% at 1 year, 42.8% vs. 6.3% at 2 years and 53.4% vs. 17.8% at 3 years, p = 0.0007). The risk of aneurysm sac expansion of 5 mm or more was estimated to be 11 times greater when the IMA was patent, and 4.9 times greater when 3 or more LAs were patent at the end of EVAR. CONCLUSION: When IMA was occluded and the number of patent LA became 2 or less by aortic side branch coil embolization during EVAR, favorable mid-term results were safely obtained and good long-term result could be expected with EVAR.
引用
- Aoki A, Maruta K, Omoto T, et al. Midterm Outcomes of Endovascular Abdominal Aortic Aneurysm Repair with Prevention of type 2 Endoleak by Intraoperative Aortic Side Branch Coil Embolization. Ann Vasc Surg. 2021. PMID: 34537351. doi:10.1016/j.avsg.2021.06.037
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。