面向A型主动脉夹层的血管腔内治疗:更短的锚定区与更多患者 eligibility
本研究基于2012–2019年53例A型主动脉夹层(TAAD)患者的CT三维重建,分析解剖特征以评估血管腔内治疗可行性。47例(88.7%)破口位于最高冠状动脉开口远端,35例(66.0%)近端锚定区≥2.0 cm,25例(47.2%)可采用直径不匹配≤20%的直管支架。结论提示近80%患者近端锚定区≥1.0 cm,需更精准释放技术以扩大适应人群。
要点
- 88.7%的TAAD患者破口位于最高冠状动脉开口远端。
- 66.0%患者近端锚定区≥2.0 cm,79.2%≥1.0 cm。
- 47.2%患者解剖适合直径不匹配≤20%的直管支架。
核心结论
- 近80%的TAAD患者近端锚定区≥1.0 cm,其中47.2%解剖适合使用市售直管支架行血管腔内治疗。
- 为扩大TAAD腔内治疗适应人群,需提升短锚定区下精准释放与充分密封的技术。
研究设计与样本
- 回顾性分析2012–2019年本院53例TAAD患者的CT图像,使用OsiriX 10.0进行三维重建。
- 分析中心线长度、升主动脉与主动脉根部尺寸、夹层与冠状动脉开口的位置关系。
主要发现
- 53例患者平均年龄60.4±17.1岁,男性36例、女性17例,46例接受TAAD手术,4例术后30天内死亡。
- 47例(88.7%)破口位于最高冠状动脉开口远端,近端锚定区定义为最高冠状动脉开口至破口的距离。
- 35例(66.0%)近端锚定区≥2.0 cm,38例(71.7%)≥1.5 cm,42例(79.2%)≥1.0 cm。
- 窦管交界与远端升主动脉锚定区直径中位数分别为3.29 cm(IQR 2.73–4.10 cm)和3.49 cm(IQR 3.09–3.87 cm)。
- 窦管交界至无名动脉开口长度中位数8.08 cm(IQR 6.96–9.40 cm),升主动脉曲率半径中位数6.48 cm(IQR 5.27–8.00 cm)。
临床怎么用
- 术前CT三维重建可评估TAAD破口位置、锚定区长度与直径,辅助筛选腔内治疗候选者。
- 近端锚定区≥1.0 cm且直径不匹配≤20%的患者可考虑直管支架腔内治疗。
局限性
- 回顾性单中心研究,样本量53例,结论需更大样本验证。
- 解剖可行性基于影像分析,未报告实际腔内治疗临床结局。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Type A or ascending aortic dissection is an acute life-threatening condition with high morbidity and mortality. Open surgery remains the standard of care. The development of minimally invasive endografts for type A aortic dissection (TAAD) will require a detailed understanding of the dissection and aortic root anatomy to determine patient eligibility and optimal device specifications. METHODS: Computed tomography images of TAAD cases at our institution from 2012 to 2019 were identified, and three-dimensional reconstructions were performed using OsiriX, version 10.0 (Pixmeo SARL, Bernex, Switzerland). We analyzed key anatomic structures, including centerline length measurements, ascending aorta and aortic root dimensions, and the location and extent of dissection in relationship to the coronary ostia. RESULTS: A total of 53 patients were identified (mean ± standard deviation age, 60.4 ± 17.1 years; 36 men and 17 women), 46 of whom had undergone surgery for TAAD. Four patients had died within 30 days of surgery. In 47 patients (88.7%), the entry tear was distal to the highest coronary ostium. These cases were retrospectively considered for endovascular intervention using a nonbranched, single endograft stent. The proximal landing zone (LZ) was defined as the distance from the highest coronary ostium to the entry tear. Of the 53 patients, 35 (66.0%) had a proximal LZ length of ≥2.0 cm, 38 (71.7%) had a proximal LZ length of ≥1.5 cm, and 42 (79.2%) had a proximal LZ length of ≥1.0 cm. The median proximal and distal LZ diameters of the sinotubular junction (STJ) and distal ascending aorta regions were 3.29 cm (interquartile range [IQR], 2.73-4.10 cm) and 3.49 cm (IQR, 3.09-3.87 cm, respectively), with a median length from the STJ to the innominate takeoff of 8.08 cm (IQR, 6.96-9.40 cm). The median ascending aorta radius of curvature was 6.48 cm (IQR, 5.27-8.00 cm). Of the 53 patients, 25 (47.2%) could be treated with a straight tube graft with a ≤20% diameter mismatch between the proximal and distal LZs. CONCLUSIONS: Almost 80% of the patients with TAAD had had a proximal LZ of ≥1.0 cm. Of these patients, 47.2% had anatomy amenable for endovascular therapy with a nontapered straight tube graft using commercially available devices. To increase patient eligibility for TAAD endovascular intervention, enhanced precision deployment with an adequate seal in shorter LZs will be required. Our results can serve as a guide for endovascular device specifications designed to treat this devastating condition.
引用
- Wisneski AD, Kumar V, Vartanian SM, et al. Toward endovascular treatment of type A aortic dissection with smaller landing zones and more patient eligibility. J Vasc Surg. 2021. PMID: 34500032. doi:10.1016/j.jvs.2021.08.054
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。