二氧化碳血管造影在开窗式EVAR中开窗与靶血管错位时的益处与作用
该技术报告描述在2例开窗式腔内动脉瘤修复(F-EVAR)中,开窗与靶血管错位且标准造影无法显示靶血管时,二氧化碳(CO2)血管造影用于评估靶血管通畅性和相对位置,并指导补救操作以完成双肾动脉插管,两例手术均成功完成。
要点
- F-EVAR中开窗与靶血管错位可致靶血管急性闭塞,标准造影可能无法显示靶血管。
- CO2血管造影可明确靶血管通畅性及开窗与靶血管的相对位置。
- CO2血管造影可指导补救操作以完成肾动脉插管。
核心结论
- F-EVAR中开窗错位且标准造影未显示靶血管时,CO2血管造影可独特且互补地明确靶血管通畅性与位置并指导补救操作。
研究设计与样本
- 技术报告,描述2例F-EVAR中开窗与靶血管错位患者的处理经验。
主要发现
- 2例患者在放置开窗移植物后不同投照角度标准造影及插管对应开窗后,靶血管均未显示。
- 两例中移植物贴附于主动脉壁但位置不可预测,曾怀疑靶血管急性闭塞。
- CO2血管造影用于评估靶血管通畅性并明确开窗与靶血管相对位置。
- 在CO2血管造影指导下实施补救操作,完成双肾动脉插管,两例手术均成功完成。
临床怎么用
- F-EVAR中开窗与靶血管错位且标准造影未显示靶血管时,可考虑使用CO2血管造影评估靶血管通畅性与位置。
- CO2血管造影可用于指导补救操作以完成靶血管插管。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To report the benefits and the role of carbon dioxide (CO2) angiography in case of misalignment between fenestration and target vessel during fenestrated endovascular aneurysm repair (F-EVAR). TECHNIQUE: During F-EVAR, misalignment between fenestration and target vessel is a potentially catastrophic complication. In 2 patients, we experienced that one of the target vessels were not visible during standard angiography in different projections after positioning a fenestrated graft and even after cannulation of the corresponding fenestration. In both cases, the graft was sealed to the aortic wall but not in the predictable position. Consequently, acute occlusion of the target vessel was hypothesized. However, CO2 angiography was useful to evaluate patency of the target vessel clarifying the relative position of the fenestration versus the target vessel. Rescue maneuvers were feasible under the guidance of CO2 angiography in order to obtain the cannulation of both renal arteries. In both cases, the procedure was successfully accomplished. CONCLUSION: In case of misalignment of a fenestration during F-EVAR and non-visualization of the target vessel with standard angiography, CO2 angiography could have the unique and complementary role of clarifying the patency and position of the target vessel. In addition, CO2 could guide the rescue maneuvers.
引用
- Chisci E, Michelagnoli S, Masciello F, et al. Benefits and Role of Carbon Dioxide Angiography in Case of Misalignment Between Fenestration and Target Vessel During Fenestrated Endovascular Aneurysm Repair. J Endovasc Ther. 2021. PMID: 34369173. doi:10.1177/15266028211032955