文献速递主动脉疾病

犬模型TEVAR后逆行性A型夹层中支架移植物与主动脉相互作用的计算研究与组织病理学验证

Computational Investigation and Histopathological Validation of Interaction Between Stent Graft and Aorta in Retrograde Type A Dissection After TEVAR in Canine Models.
PubMed 文献 · J Endovasc Ther · 2021-08-13

本研究在2只犬主动脉植入定制Fabulous®支架移植物,通过计算模拟和病理检查评估支架与主动脉的相互作用。结果显示最大主动脉应力位于近端裸支架与主动脉大弯侧接触处,犬1该处发生RTAD且应力显著高于犬2(0.415±0.210 vs 0.200±0.160 MPa,p<0.01),病理见内膜片、假腔、弹性蛋白改变及中膜坏死,提示高应力可能致RTAD。

要点

  • 最大主动脉应力位于近端裸支架与大弯侧主动脉壁接触处。
  • 犬1最大应力显著高于犬2,且该处发生逆行性A型夹层。
  • 计算模拟与体内病理结果一致,高应力可能致RTAD。

核心结论

  • 最大主动脉应力特征性分布于近端裸支架顶点与大弯侧主动脉壁相互作用处,该处高应力可能引起逆行性A型夹层。

研究设计与样本

  • 在2只犬主动脉植入2枚定制Fabulous®支架移植物,着陆位置相距5 mm。
  • 基于植入支架构建计算模型,每个犬模型进行7次TEVAR模拟并计算最大主动脉应力。
  • 植入3个月后获取犬主动脉,行HE和EVG染色评估组织病理学改变。

主要发现

  • 两犬计算模型中最大主动脉应力均位于近端裸支架处主动脉大弯侧,近端裸支架对主动脉壁产生的应力高于其他支架部分。
  • 犬1最大主动脉应力显著高于犬2(0.415±0.210 vs 0.200±0.160 MPa,p<0.01)。
  • 犬1最大应力段发生RTAD,病理示内膜片、假腔、弹性蛋白改变及中膜坏死;犬2未发生RTAD。
  • 两犬支架覆盖的主动脉均见中膜坏死、弹性纤维牵拉和炎性浸润。

临床怎么用

  • 计算模拟可用于研究TEVAR后RTAD的发生机制,识别高应力区域。
  • 近端裸支架与大弯侧主动脉壁接触处的高应力值得临床关注。

局限性

  • 研究仅纳入2只犬模型,样本量小。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Retrograde type A dissection (RTAD) after thoracic endovascular aortic repair (TEVAR) has been a major drawback of endovascular treatment. To our knowledge, no studies have simulated and validated aortic injuries caused by stent grafts (SGs) in animal models. Therefore, the aim of this study was to evaluate and quantify the SG-aorta interaction through computational simulations and to investigate the underlying mechanism through histopathological examinations. METHODS: Two custom-made Fabulous® (DiNovA Meditech, Hang Zhou, China) SGs were implanted in 2 canine aortas with a 5-mm difference in the distance in landing locations. The aortic geometries were extracted from RTAD and non-RTAD cases. A computational SG model was assembled based on the implanted SG using the software Pro-ENGINEER Wildfire 5.0 (PTC Corporation, Needham, Mass). TEVAR simulations were performed 7 times for each canine model using Abaqus software (Providence, RI, USA), and the maximum aortic stress (MAS) was calculated and compared among the groups. Three months after SG implantation, the canine aortas were harvested, and were examined using hematoxylin and eosin staining and Elastica Van Gieson (EVG) staining to evaluate histopathological changes. RESULTS: In the computational models for both canines, MAS was observed at the proximal bare stent (PBS) at aortic greater curve. The PBS generated higher stress toward the aortic wall than other SG parts did. Moreover, the MAS was significantly higher in canine No.1 than in canine No.2 (0.415±0.210 versus 0.200±0.160 MPa) (p<0.01). Notably, in canine No.1, an RTAD developed at the MAS segment, and histopathological examinations of the segment showed an intimal flap, a false lumen, elastin changes, and medial necrosis. RTAD was not observed in canine No.2. In both SG-covered aortas, medial necrosis, elastic fiber stretching, and inflammatory infiltration were seen. CONCLUSION: The characteristic MAS distribution remained at the location where the apex of the PBS interacted with the aortic wall at greater curve. RTAD histopathological examinations showed intimal damage and medial necrosis at the proximal landing zone, at the same MAS location in computational simulations. The in vivo results were consistent with the computational simulations, suggesting the MAS at greater curve may cause RTAD, and the potential application of computational simulation in the mechanism study of RTAD.