文献速递主动脉疾病

动态时间分辨CTA技术表征主动脉内漏类型、流入道并指导靶向治疗

Dynamic, Time-Resolved Computed Tomography Angiography Technique to Characterize Aortic Endoleak Type, Inflow and Provide Guidance for Targeted Treatment.
PubMed 文献 · J Endovasc Ther · 2021-08-13

该技术采用第三代CT扫描仪行多次时间分辨增强扫描,通过时间-衰减曲线分析定量表征主动脉内漏类型及流入道,并利用2D-3D图像融合在术中提供靶向治疗引导。4例示范病例涵盖I型、II型(肠系膜下动脉和腰动脉流入)及III型内漏,时间-衰减曲线分析有助于更好区分内漏类型与流入道。

要点

  • 动态时间分辨CTA联合时间-衰减曲线分析可定量表征主动脉内漏类型与流入道。
  • 扫描视野、kV及扫描次数/时序根据BMI、团注时序和既往影像个性化调整。
  • 2D-3D图像融合将d-CTA标注的靶血管叠加于透视,为靶向治疗提供引导。

核心结论

  • 动态时间分辨CTA结合时间-衰减曲线分析可表征主动脉内漏类型和流入道,并为靶向内漏治疗提供图像引导。

研究设计与样本

  • 技术说明性研究,使用第三代CT扫描仪行多次时间分辨增强扫描,纳入4例示范病例(I型、II型及III型内漏)。

主要发现

  • 4例示范病例展示了I型、II型(肠系膜下动脉和腰动脉流入)及III型内漏的d-CTA表现。
  • 时间-衰减曲线分析中的达峰时间参数有助于更好表征内漏类型和流入道。

关键数值与推荐

  • 扫描视野、kV、扫描次数/时序根据患者BMI、团注时序和既往影像发现定制。
  • 图像数据集经运动校正后使用专用软件(syngo.via®)进行时间-衰减曲线定性与定量分析。

临床怎么用

  • 在内漏介入治疗中,可将d-CTA图像标注的靶血管通过2D-3D图像融合叠加于透视,引导靶向治疗。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To illustrate dynamic, time-resolved CTA (d-CTA) imaging technique in characterizing aortic endoleak type/inflow using quantitative parameters and its value in providing image guidance for targeted treatment approach. TECHNIQUE: Dedicated endoleak protocol involved acquiring multiple time-resolved contrast enhanced scans using third-generation CT scanner (Somatom Force®, Siemens Healthineers). Parameters such as scan field of view (FOV), kV, number/timing of scans were customized based on patient's body-mass-index, timing bolus, and prior imaging findings. D-CTA image datasets were evaluated qualitatively and quantitatively using time-attenuation curves (TAC) analysis after motion correction using a dedicated software (syngo.via®, Siemens). D-CTA findings from 4 illustrative cases demonstrating type I, type II (inferior mesenteric and lumbar artery inflow), and type III endoleak were illustrated. TAC analysis with time to peak parameter enabled better characterization of endoleak type and inflow. During endoleak intervention, target vessels from d-CTA images were electronically annotated and overlaid on fluoroscopy using 2D-3D image fusion to provide image guidance for targeted treatment. CONCLUSION: D-CTA imaging with TAC analysis characterizes aortic endoleak type and inflow, in addition to providing image guidance for targeted endoleak treatment. Such dynamic, time-resolved imaging techniques may provide further insights into understanding aortic endoleak that remains an Achilles heel for endovascular aortic aneurysm repair.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Berczeli M, Lumsden AB, Chang SM, et al. Dynamic, Time-Resolved Computed Tomography Angiography Technique to Characterize Aortic Endoleak Type, Inflow and Provide Guidance for Targeted Treatment. J Endovasc Ther. 2021. PMID: 34384284. doi:10.1177/15266028211037986

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。