文献速递颈动脉与弓上血管

术中近红外光谱在区域麻醉下颈动脉内膜切除术中的诊断准确性:系统评价与Meta分析

The Diagnostic Accuracy of Intra-Operative Near Infrared Spectroscopy in Carotid Artery Endarterectomy Under Regional Anaesthesia: Systematic Review and Meta-Analysis.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2021-07-17

该系统评价与Meta分析评估了术中近红外光谱(NIRS)在区域麻醉下颈动脉内膜切除术(CEA)中检测脑缺血的诊断准确性。结论认为NIRS单独用于神经监测的准确性不足。

要点

  • NIRS检测脑缺血的汇总敏感度72.0%、特异度84.1%,准确性中等。
  • 预测30天卒中的敏感度仅41%,不宜单独用于术后卒中风险判断。
  • 高血压和糖尿病比例高与敏感度降低相关,症状性颈动脉狭窄与敏感度升高相关。

核心结论

  • NIRS作为脑监测技术,在区域麻醉下CEA患者中单独用于神经监测的敏感度和特异度不够高。

主要发现

  • 诊断脑缺血的汇总敏感度为72.0%(95%CI 58.1-82.7;I2=48.6%),特异度为84.1%(95%CI 78.5-88.4;I2=48.6%)。
  • 诊断脑缺血的汇总受试者工作特征曲线部分面积为0.646。
  • 预测30天卒中的点估计敏感度为41%(95%CI 19.5-66.6;I2=0%),特异度为81.4%(95%CI 74.4-86.9;I2=65.6%)。

临床怎么用

  • NIRS不应单独用于区域麻醉下CEA术中的神经监测,需结合清醒试验等其他方法。
  • 对合并高血压、糖尿病的患者,NIRS的敏感度可能更低,解读结果需谨慎。

局限性

  • 研究间存在异质性(I2=48.6%),部分分析异质性较高(如预测30天卒中特异度I2=65.6%)。
  • 纳入研究数量有限(11项),可能影响结论的稳健性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Intra-operative near infrared spectroscopy (NIRS) is a non-invasive tool used to monitor regional cerebral oxygen saturation during carotid endarterectomy (CEA), for which accuracy remains unclear. Therefore, this systematic review and meta-analysis aimed to determine the diagnostic accuracy of NIRS in patients undergoing CEA under regional anaesthesia (RA). DATA SOURCES: MEDLINE, Scopus, and Web of Science were searched for studies that compared NIRS with the "awake test" in patients undergoing CEA under RA. REVIEW METHODS: Bivariable random effects meta-analysis was performed to determine the diagnostic accuracy of NIRS to detect cerebral ischaemia. Meta-regression was performed to explore causes of heterogeneity. Meta-analysis of proportions was also performed to determine the accuracy of NIRS in predicting 30 day stroke. Study quality was evaluated using the QUADAS-2 criteria. RESULTS: Eleven primary studies were included, assessing 1 237 participants. The meta-analysis obtained a partial area under the summary receiver operating characteristic curve for diagnosing brain ischaemia of 0.646, with a summary sensitivity of 72.0% (95% confidence interval [CI] 58.1 - 82.7; I2 = 48.6%) and a specificity of 84.1% (95% CI 78.5-88.4; I2 = 48.6%). In meta-regression analysis, the frequency of hypertension (p = .011) and patients with symptomatic carotid stenosis (p = .031) were significant effect modifiers. Higher frequency of arterial hypertension (z score = -2.15; p = .032) and diabetes (z score = -2.12; p = .034) were associated with lower summary sensitivity, while a higher frequency of symptomatic carotid stenosis (z score = 2.11; p = .035) was associated with higher summary sensitivity. Point estimate sensitivity and specificity for predicting 30 day stroke occurrence were 41% (95% CI 19.5 - 66.6; I2 = 0%) and 81.4% (95% CI 74.4 - 86.9, I2 = 65.6%), respectively. CONCLUSION: The results of this study suggest that NIRS as a cerebral monitoring technique does not have sufficiently high sensitivity or specificity to be used alone in the neurological monitoring of patients undergoing CEA under RA.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Duarte-Gamas L, Pereira-Neves A, Sousa J, et al. The Diagnostic Accuracy of Intra-Operative Near Infrared Spectroscopy in Carotid Artery Endarterectomy Under Regional Anaesthesia: Systematic Review and Meta-Analysis. Eur J Vasc Endovasc Surg. 2021. PMID: 34284934. doi:10.1016/j.ejvs.2021.05.042

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。