文献速递颈动脉与弓上血管

颈动脉超声斑块弹性与斑块内新生血管:组织学对照研究

Plaque Elasticity and Intraplaque Neovascularisation on Carotid Artery Ultrasound: A Comparative Histological Study.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2021-01-01

结果显示CEUS测得的斑块面积与SWV、MVD、胶原比值和MMP-9相关,SWE与I/III型胶原比值正相关,提示新生血管越丰富斑块弹性越低。

要点

  • CEUS评估的斑块面积与MVD、MMP-9正相关,与SWV、I/III型胶原比值负相关。
  • SWE测得的SWV与I/III型胶原比值呈正相关。
  • 斑块内新生血管越丰富,斑块弹性越低,二者呈负相关。

核心结论

  • SWE和CEUS可综合评估颈动脉斑块的弹性及斑块内新生血管,从而判断斑块易损性。
  • 斑块内新生血管与弹性呈负相关,组织学发现进一步验证了新生血管越丰富、弹性越低。

研究设计与样本

  • 术后斑块行免疫组化染色和形态学分析,检测微血管密度(MVD)、MMP-9表达及I/III型胶原比值。
  • 采用相关分析建立上述定量参数间的关系,并用组内相关系数和Bland-Altman图评估观察者间和观察者内一致性。

主要发现

  • CEUS测得的斑块面积与SWV相关(r=-.714; p<.001),与MVD相关(r=.842; p<.001),与I/III型胶原比值相关(r=-.833; p<.001),与MMP-9相关(r=.738; p<.001)。
  • SWE测得的SWV与I/III型胶原比值呈正相关(r=.805; p<.001)。
  • SWE的总体检查者间一致性可接受(r=.638; p<.001)。
  • AUC、TP、MTT和SWV的观察者间相关系数分别为.719、.756、.733和.686。
  • AUC、TP、MTT和SWV的观察者内变异度分别为.826、.845、.633和.748。

临床怎么用

  • SWE和CEUS可用于无创评估颈动脉斑块弹性及新生血管,辅助判断斑块易损性。
  • 斑块内新生血管丰富且弹性降低时,提示斑块易损性增高,可帮助临床决策。

局限性

  • 研究仅纳入有症状且狭窄>70%的患者,结论外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Plaque elasticity and intraplaque neovascularisation are strongly suggestive of vulnerable plaque. This study aimed to investigate the relationship between intraplaque neovascularisation and plaque elasticity, and to compare the ultrasound findings with histopathological changes. METHODS: Patients enrolled in this study presented with symptomatic carotid stenosis (> 70%) and later underwent both pre-operative ultrasonography and endarterectomy. Contrast enhanced ultrasound (CEUS) and shear wave elastography (SWE) were used to measure the neovascularisation and elasticity of the plaque, respectively. After removal, plaques were histologically assessed to determine the microvessel density (MVD), matrix metalloproteinase (MMP)-9 expression, and type I/type III collagen ratio using immunohistochemistry staining and morphometry. A correlation analysis was used to establish the relationship among the aforementioned quantitative parameters. Inter- and intra-observer consistency evaluations were performed using the intraclass correlation coefficient and Bland-Altman plots. RESULTS: Ninety-four symptomatic patients with 98 plaques were included. The area under the curve (AUC) of the carotid plaque detected using CEUS correlated with its shear wave velocity (SWV) (r = -.714; p < .001), MVD (r = .842; p < .001), collagen type I/III ratio (r = -.833; p < .001), and MMP-9 (r = .738; p < .001). SWE was positively correlated with the type I/III collagen ratio (r = .805; p < .001). The overall interexaminer consistency of the SWE was acceptable (r = .638; p < .001). The interobserver correlation coefficient of the AUC, time to peak (TP), mean transit time (MTT), and SWV were .719, .756, .733, and .686, respectively. The intra-observer variability values of the AUC, TP, MTT, and SWV were .826, .845, .633, and .748, respectively. CONCLUSION: SWE and CEUS can comprehensively evaluate the vulnerability of the carotid plaque by assessing the elasticity of the plaque and neovascularisation within it. The negative correlation between the intraplaque neovascularisation and elasticity, further validated by histological findings, suggests that the more abundant the neovascularisation, the less elasticity.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Zhang Y, Cao J, Zhou J, et al. Plaque Elasticity and Intraplaque Neovascularisation on Carotid Artery Ultrasound: A Comparative Histological Study. Eur J Vasc Endovasc Surg. 2021. PMID: 34266763. doi:10.1016/j.ejvs.2021.05.026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。