文献速递主动脉疾病

TEVAR术中支架移植物致主动脉内膜套叠的腔内修复

Intraoperative Stent-Graft-Induced Aortic Intimal Intussusception During TEVAR for Type B Aortic Dissection.
PubMed 文献 · J Endovasc Ther · 2021-07-07

本研究定义并报道了B型主动脉夹层TEVAR术中支架移植物导致的内膜套叠(ISAII),发生率1.28%(14/1096),按位置分为三型,所有病例均经腔内修复,随访27.36个月显示病变稳定且分支与支架通畅。

要点

  • TEVAR术中ISAII发生率1.28%,需术中准确识别。
  • 按内膜片脱离范围分为三型,指导腔内修复策略。
  • 腔内修复各型ISAII有效且中期随访结果稳定。

核心结论

  • ISAII是TEVAR术中的罕见但可能致命的并发症,腔内修复有效且持久。

研究设计与样本

  • 单中心回顾性分析,2014年1月至2020年6月共1096例B型主动脉夹层TEVAR患者中14例发生ISAII。

主要发现

  • ISAII发生率为1.28%(14/1096)。
  • 按内膜片位置分为三型:I型限于预定支架覆盖段内,II型超出覆盖段但未累及内脏分支,III型累及内脏分支。
  • 平均随访27.36个月(范围5-71个月),所有ISAII病变稳定,主要主动脉分支、支架移植物及裸支架均通畅。

关键数值与推荐

  • ISAII定义为腔内治疗术中远端内膜片部分或环形撕裂。
  • 根据内膜片位置分为三型指导治疗。

临床怎么用

  • TEVAR术中应警惕ISAII,准确诊断并立即行腔内修复。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Aortic intimal intussusception is well described in the natural progression of type A aortic dissection. Only 3 cases of aortic intimal intussusception were reported to be related to thoracic endovascular aortic repair (TEVAR) for Stanford type B aortic dissection. In our study, we are reporting a rare but potentially fatal complication, the intraoperative stent-graft (SG)-induced aortic intimal intussusception (ISAII); this study reports a series of endovascular repair for ISAII cases. By presenting the ISAII definition, the diagnostic steps to rule out or to identify the condition, and the techniques to resolve it, we intended to raise the awareness of this severe complication, so that physicians can adapt to overcome the complications while performing TEVAR. MATERIALS AND METHODS: ISAII was defined as the partial or circumferential disruption of the distal intimal flap as an intraoperative complication of endovascular treatment. From January 2014 to June 2020, 1,096 patients underwent TEVAR for Stanford type B aortic dissection at our hospital. Among them, 14 ISAII complications were witnessed. All these patients underwent endovascular repair for ISAII lesions, and their data were extracted for analysis. RESULTS: The ISAII lesions were classified into 3 types according to their location in different aortic segments: type I, ISAII was limited within the intended SG coverage segment; type II, ISAII occurred after SG introduction or deployment, and the detached intimal flap extended beyond the intended SG coverage segment but did not affect the abdominal aortic visceral branches; type III, ISAII occurred during SG introduction or deployment, and the detached intimal flap descended to the abdominal aortic segment with visceral branches. Our results showed ISAII as a rare complication with an incidence of 1.28% (14/1096), and endovascular repair for all types of ISAII is an effective treatment. With a mean follow-up of 27.36 months (range 5-71 months), all the ISAII lesions were stable, and all the major aortic branches, SGs, and bare stents were patent. CONCLUSIONS: The management of this potentially devastating intraoperative complication relies on accurate diagnosis and prompt management. Our results suggested that endovascular repair for ISAII is effective and durable for correcting this complication. GRAPHICAL ABSTRACT: [Formula: see text].

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Ma T, Liu F, Chen B, et al. Intraoperative Stent-Graft-Induced Aortic Intimal Intussusception During TEVAR for Type B Aortic Dissection. J Endovasc Ther. 2021. PMID: 34229510. doi:10.1177/15266028211028213

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。