吲哚菁绿近红外荧光成像评估截肢术后组织活力
本试点研究纳入因外周动脉疾病或糖尿病行下肢截肢的成人患者,术后5天内用吲哚菁绿近红外荧光成像评估截肢创面灌注。15例截肢中4处出现低荧光区,均发生相应区域愈合不良,3例需再截肢;低荧光区达峰时间显著延长且5分钟流出下降更少。
要点
- ICG近红外荧光成像可在术后预测截肢创面皮肤坏死。
- 低荧光区达峰时间113秒 vs 32秒,5分钟流出下降80.3% vs 57.0%。
- 荧光强度受相机角度、距离和ICG剂量影响,量化仍具挑战。
核心结论
- ICG近红外荧光成像在本研究中预测了全部4例术后皮肤坏死,但量化区域灌注仍受多种因素影响。
研究设计与样本
- 试点研究,纳入因外周动脉疾病或糖尿病行下肢截肢的成人患者,术后5天内用Quest Spectrum平台行ICG近红外荧光成像,共10例患者15次截肢。
主要发现
- 15处截肢创面中11处未见低荧光区,其中10处随访期间无愈合问题。
- 4处截肢创面见低荧光区,均发生相应区域愈合不良,其中3处需再截肢。
- 低荧光区达峰时间显著长于正常区(113秒 vs 32秒,P=0.003)。
- 低荧光区5分钟流出下降显著少于正常区(80.3% vs 57.0%,P=0.003)。
关键数值与推荐
- 低荧光区定义为ICG近红外荧光成像中观察到的荧光缺损区域。
- 荧光强度参数在患者间差异较大,受相机角度、相机距离和ICG剂量影响。
临床怎么用
- 术后可用ICG近红外荧光成像识别截肢创面低灌注区域,辅助判断愈合风险与再截肢风险。
- 因缺乏可靠截断值,目前不宜单独依据荧光参数决定手术决策。
局限性
- 试点研究样本量小(10例患者15次截肢)。
- 荧光强度受相机角度、距离和ICG剂量影响,量化困难。
- 需前瞻性研究确定预测创面愈合的可靠截断值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Patients with chronic limb threatening ischemia have a risk of undergoing a major amputation within 1 year of nearly 30% with a substantial risk of re-amputation since wound healing is often impaired. Quantitative assessment of regional tissue viability following amputation surgery can identify patients at risk for impaired wound healing. In quantification of regional tissue perfusion, near-infrared (NIR) fluorescence imaging using Indocyanine Green (ICG) seems promising. METHODS: This pilot study included adult patients undergoing lower extremity amputation surgery due to peripheral artery disease or diabetes mellitus. ICG NIR fluorescence imaging was performed within 5 days following amputation surgery using the Quest Spectrum PlatformⓇ. Following intravenous administration of ICG, the NIR fluorescence intensity of the amputation wound was recorded for 10 minutes. The NIR fluorescence intensity videos were analyzed and if a fluorescence deficit was observed, this region was marked as "low fluorescence." All other regions were marked as "normal fluorescence." RESULTS: Successful ICG NIR fluorescence imaging was performed in 10 patients undergoing a total of 15 amputations. No "low fluorescence" regions were observed in 11 out of 15 amputation wounds. In 10 out of these 11 amputations, no wound healing problems occurred during follow-up. Regions with "low fluorescence" were observed in 4 amputation wounds. Impaired wound healing corresponding to these regions was observed in all wounds and a re-amputation was necessary in 3 out of 4. When observing time-related parameters, regions with low fluorescence had a significantly longer time to maximum intensity (113 seconds vs. 32 seconds, P = 0.003) and a significantly lesser decline in outflow after five minutes (80.3% vs. 57.0%, P = 0.003). CONCLUSIONS: ICG NIR fluorescence imaging was able to predict postoperative skin necrosis in all four cases. Quantitative assessment of regional perfusion remains challenging due toinfluencing factors on the NIR fluorescence intensity signal, including camera angle, camera distance and ICG dosage. This was also observed in this study, contributing to a large variety in fluorescence intensity parameters among patients. To provide surgeons with reliable NIR fluorescence cut-off values for prediction of wound healing, prospective studies on the intra-operative use of this technique are required. The potential prediction of wound healing using ICG NIR fluorescence imaging will have a huge impact on patient mortality, morbidity as well as the burden of amputation surgery on health care.
引用
- Van Den Hoven P, Van Den Berg SD, Van Der Valk JP, et al. Assessment of Tissue Viability Following Amputation Surgery Using Near-Infrared Fluorescence Imaging With Indocyanine Green. Ann Vasc Surg. 2021. PMID: 34182113. doi:10.1016/j.avsg.2021.04.030
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。