BeGraft Peripheral Plus在胸腹主动脉瘤分支腔内修复中的早期结果
本研究评估BeGraft Peripheral Plus(B+)作为分支腔内主动脉修复(BEVAR)中桥接支架的早期结局。46例患者共163条内脏分支,中位随访15个月,技术成功率高,2年分支通畅率98%,分支相关不稳定事件4例(2.4%)。
要点
- B+作为BEVAR桥接支架早期通畅率满意,2年分支通畅率98%。
- 21%分支需额外支架延长以优化密封,仅3%需自膨胀裸支架修整远端过渡区。
- 分支相关不稳定事件发生率低(2.4%),包括2例闭塞和2例晚期再干预。
核心结论
- B+作为BEVAR桥接支架早期结局满意,闭塞和再干预率低。
- 为达到目标血管充分密封可能需要延长桥接支架,但分支常规再衬不需要。
研究设计与样本
- 回顾性纳入自2017年B+上市后连续接受BEVAR并使用B+作为桥接支架的患者。
- 共46例患者、163条内脏分支(69条内分支,94条内/外分支),中位随访15个月(范围4-36个月)。
主要发现
- 所有内脏分支获得主要技术成功,仅1条桥接支架需逐级扩张至完全展开。
- 2年总体分支通畅率为98%。
- 35条分支(21%)在B+部署后需额外支架覆盖更长桥接距离并优化近远端密封。
- 仅3%分支需自膨胀裸镍钛支架修整桥接支架与目标血管间远端过渡区。
- 分支相关不稳定事件4例(2.4%),包括2例闭塞和2例因部分支架内血栓形成晚期再干预。
临床怎么用
- B+可作为BEVAR中内脏分支的桥接支架选择,早期通畅率良好。
- 术中应根据桥接距离和密封需要决定是否延长桥接支架,不推荐常规再衬。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: No bridging stent-graft (BSG) has been specifically designed for branched endovascular aortic repair (BEVAR) and therefore different "off-label" stent-grafts have been used. Recently, a third generation of balloon-expandable stent-graft has become available. Here we evaluate the outcomes of the BeGraft Peripheral Plus (B+) used as a BSG for internal/externalor inner branches during BEVAR. MATERIALS AND METHODS: Consecutive patients undergoing BEVAR using B+ as a BSG since its release in 2017 were included into the study. The primary endpoints were technical success and target vessel patency during follow-up. Secondary endpoints included the need for adjunct extension and relining of the BSG, branch instability rate, including occlusion, reinterventions for restonosis, kink, fracture, or endoleak (types 1 and 3). RESULTS: A total of 163 visceral branches in 46 patients were included with a median follow-up 15 months (4-36 months). Primary technical success was achieved in all visceral branches (69 inner branches and 94 internal/external branches) with the exception of 1 BSG that required serial dilatation until full expansion was achieved with overall branch patency was 98% at 2 years. An additional stent-graft was necessary in 35 branches (21%) following deployment of a B+ BSG to cover a longer bridging distance and optimize the distal and proximal sealing. Relining of B+ BSG was not routinely carried out during the index procedure and a self-expanding uncovered nitinol stent was necessary in only 3% of branches to smooth the distal transition zone between the BSG and target vessel. There were 4 events (2.4%) of branch related instability, including 2 occlusions and 2 late reinterventions for a partial in-stent-graft thrombosis. CONCLUSION: Our study findings show satisfactory early outcomes of B+ as a BSG in BEVAR with low occlusion and reintervention rates. Extensions of BSG might be required to achieve adequate seal in the target vessels but routine relining BSG in branches was not required.
引用
- Abisi S, Gkoutzios P, Carmichael M, et al. The Early Outcomes of BeGraft Peripheral Plus in Branched Endovascular Repair of Thoracoabdominal Aneurysms. J Endovasc Ther. 2021. PMID: 34160322. doi:10.1177/15266028211025019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。