文献速递主动脉疾病

激光辅助「剪刀」技术促进慢性B型主动脉夹层的胸主动脉腔内修复

Laser-assisted "Scissor" Technique to Facilitate Thoracic Endovascular Aortic Repair for Chronic Type B Aortic Dissection.
PubMed 文献 · Ann Vasc Surg · 2021-06-26

本文介绍一种激光开窗联合撕裂内膜片离断的辅助技术,用于慢性B型主动脉夹层合并动脉瘤的TEVAR术中,以避免逆行假腔灌注。两例患者(一例原发修复,一例象鼻术后二期完成)均获技术成功,无I/III型内漏,假腔无血流,内脏血管通畅。早期随访证实动脉瘤被隔绝,无逆行假腔灌注证据。

要点

  • 激光辅助「剪刀」技术可作为TEVAR辅助手段,用于慢性B型夹层合并动脉瘤。
  • 在IVUS引导下激光开窗并离断内膜片,创建远端密封区,避免逆行假腔灌注。
  • 两例患者技术成功,无I/III型内漏,假腔无血流,内脏血管通畅。

核心结论

  • 慢性夹层背景下的胸主动脉瘤可通过TEVAR联合激光离断慢性夹层内膜片成功治疗,完全隔绝动脉瘤并避免逆行假腔灌注。

研究设计与样本

  • 本文为技术综述,回顾一种治疗胸主动脉瘤合并慢性夹层的辅助技术,报告两例患者经验。

主要发现

  • 两例患者接受TEVAR联合激光离断夹层内膜片,其中一例为慢性B型夹层合并动脉瘤的原发修复,另一例为象鼻术后二期完成。
  • 两例均获技术成功,成功植入内移植物,无I型和III型内漏。
  • 完成造影证实假腔无血流且内脏血管通畅,IVUS证实真腔通畅及内膜片被离断。
  • 早期随访证实动脉瘤被隔绝,无逆行假腔灌注证据。

临床怎么用

  • 在IVUS引导下对内膜片行激光开窗,随后以「剪刀」技术离断夹层内膜片,创建远端密封区。
  • 内膜片离断后放置支架移植物,允许移植物扩张并贴附整个主动脉外层,避免假腔逆行灌注。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: There has been an increase in utilization of thoracic endovascular aortic repair (TEVAR) to treat aneurysms with chronic dissection. Despite significant progress, TEVAR is hindered by persistent perfusion of the false lumen and aneurysm growth. Various techniques to address false lumen perfusion exist. We preset our experience of laser fenestration with disruption of the dissection flap to facilitate TEVAR and avoid persistent retrograde false lumen perfusion. METHODS: Review a technique to treat patients with thoracic aortic aneurysm complicated by chronic dissection. This is an adjunct to a TEVAR procedure with final goal to treat the aneurysm and avoid retrograde false lumen perfusion. Under IVUS guidance, we performed a Phillips/Spectranetics laser fenestration of the intimal flap followed by a scissoring technique to obliterate the dissection flap and create a distal seal zone. Stent-grafts placed following flap obliteration allow graft expansion and apposition to the entire outer aortic and avoid retrograde perfusion of the false lumen. RESULTS: Two patients underwent TEVAR in conjunction with laser obliteration of the dissection flap, including 1 undergoing primary repair of a chronic Type B dissection with aneurysm, and 1 as a completion second stage elephant trunk procedure. Technical success was achieved in both cases, with successful implantation of the endograft, and freedom from type I and III endoleaks. Absence of false lumen flow, and patency of the visceral vessels was confirmed on completion angiography. True lumen patency and obliteration of the intimal flap were confirmed by IVUS. Early follow up confirms exclusion of the aneurysm, with no evidence of retrograde perfusion of the false lumen. CONCLUSIONS: Thoracic aortic aneurysms in the context of chronic dissections can be successfully treated with TEVAR and laser obliteration of the chronic dissection flap to fully exclude the aneurysm and avoid retrograde false lumen perfusion.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Qato K, Conway A, Northfield E, et al. Laser-assisted "Scissor" Technique to Facilitate Thoracic Endovascular Aortic Repair for Chronic Type B Aortic Dissection. Ann Vasc Surg. 2021. PMID: 34182117. doi:10.1016/j.avsg.2021.04.048

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。