文献速递主动脉疾病内脏/肾动脉与血管畸形

血管内超声在分支/开窗腔内修复术中的初步应用

Intravascular Ultrasound in Branched and Fenestrated Endovascular Aneurysm Repair: Initial Experience in a Single-Center Cohort Study.
PubMed 文献 · J Endovasc Ther · 2021-06-17

PURPOSE: To evaluate intravascular ultrasound (IVUS) safety and efficacy to detect visceral stenting issues during complex endovascular aneurysm repair through branched and fenestrated repair (B-FEVAR).…

要点

  • IVUS在B-FEVAR中安全,无IVUS相关不良事件。
  • IVUS检出12%(4/33)术中分支不稳定,造影未发现。
  • IVUS评估导致5枚(15%)血管立即修正。

核心结论

  • IVUS作为B-FEVAR术后评估的辅助成像技术是安全的,能有效检测造影遗漏的术中问题。

研究设计与样本

  • 8例BEVAR(5例标准;2例定制)和2例FEVAR(定制)。

主要发现

  • IVUS识别7处问题,其中3处在造影中疑似,57%(4/7)最终造影正常。
  • IVUS检出12%(4/33)术中分支不稳定,完成造影未识别/疑似。
  • IVUS评估导致5枚(15%)血管立即修正。
  • 57%(4/7)的问题在初次BEVAR患者中检出,43%(3/7)在因分支不稳定二次干预的患者中检出。

临床怎么用

  • 在B-FEVAR术中,可考虑使用IVUS作为辅助成像技术评估内脏支架置入后的即刻分支稳定性。
  • IVUS可检测造影遗漏的分支不稳定,指导立即修正。

局限性

  • 结果需进一步研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate intravascular ultrasound (IVUS) safety and efficacy to detect visceral stenting issues during complex endovascular aneurysm repair through branched and fenestrated repair (B-FEVAR). MATERIALS AND METHODS: A single-center retrospective analysis of 33 bridging stents assessed intraoperatively using IVUS between January and September 2020 was performed. Ten aortic aneurysm patients [7 thoracoabdominal / 1 pararenal / 2 juxtarenal; 3 females; mean age 73 years [range 70-77 years]) were included. Eight BEVAR (5 standard; 2 custom-made) and 2 FEVAR (custom-made) were performed. The study assessed the safety and efficacy of IVUS utilization to detect immediate branch instability after visceral stenting in the case of B-FEVAR. The primary safety endpoint was defined as the absence of IVUS-related adverse events. The primary efficacy endpoint was defined as the composite of technical success of the IVUS-assessment in each target visceral vessels (TVVs), the rate of IVUS-findings divided as prompting additional maneuvers or not, and the incidence of postoperative computed tomography angiography findings compared with intraoperative assessment. RESULTS: There were no IVUS-related adverse events. The technical success of the IVUS-assessment was achieved in all TVVs. No technical issues compromised the evaluation of the intended vessel. Among the 7 findings identified by IVUS, 3 were suspected at the angiography. In all, 57% (4/7) had normal final angiography. IVUS was able to detect a 12% (4/33) intraoperative branch instability not identified/suspected at the completion angiography. The IVUS assessment led to an immediate revision in 5 (15%) vessels. A total of 57% (4/7) of the issues were detected in patients undergoing primary BEVAR. The remaining 43% (3/7) was detected in patients undergoing secondary intervention for branch instability. CONCLUSION: IVUS was safe as an adjunctive imaging technique to assess completion after B-FEVAR. It demonstrated efficacy in the detection of intraoperative issues missed by angiography. Further investigations are required to validate these promising results.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Gennai S, Leone N, Saitta G, et al. Intravascular Ultrasound in Branched and Fenestrated Endovascular Aneurysm Repair: Initial Experience in a Single-Center Cohort Study. J Endovasc Ther. 2021. PMID: 34137660. doi:10.1177/15266028211025014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。