文献速递颈动脉与弓上血管

左心室辅助装置植入后颈动脉双功超声速度标准可能不明确

Carotid artery duplex velocity criteria might be equivocal after left ventricular assist device implantation.
PubMed 文献 · J Vasc Surg · 2021-05-03

该回顾性研究纳入36例LVAD植入前后均行颈动脉双功超声的患者(61条颈内动脉),比较LVAD植入前后颈动脉流速及ICA/CCA比值变化。结果显示LVAD植入后CCA PSV、ICA及CCA EDV、ICA/CCA比值均显著改变(P<.01),但狭窄<50%者变化幅度小;离心泵LVAD较轴流泵LVAD的ICA EDV增加更显著(26.0 vs 6.3 cm/s;P<.01)。现有颈动脉狭窄诊断标准在LVAD患者中可能高估或低估狭窄程度。

要点

  • LVAD植入后CCA PSV、ICA及CCA EDV、ICA/CCA比值均显著改变。
  • 狭窄<50%者流速变化幅度小,可能无临床意义。
  • 离心泵LVAD较轴流泵LVAD的ICA EDV增加更显著。

核心结论

  • LVAD植入与CCA PSV、ICA及CCA EDV、ICA/CCA比值的显著变化相关;狭窄<50%者变化幅度小,可能无临床意义。
  • 现有颈动脉狭窄诊断标准在LVAD患者中可能导致狭窄程度的高估或低估。

研究设计与样本

  • 回顾性综述,纳入2007年1月至2019年12月接受LVAD植入的患者。
  • 共36例患者(平均年龄59岁;男30例,女6例)在LVAD植入前后均行CDUS(两次检查平均间隔647天),61条ICA符合纳入标准。
  • 排除接受ECMO、颈动脉影像不可用及ICA闭塞的患者。

主要发现

  • LVAD植入后ICA PSV平均下降6.12 ± 4.34 cm/s(P = .167),ICA EDV平均增加13.44 ± 4.23 cm/s。
  • CCA PSV平均下降17.22 ± 4.95 cm/s,CCA EDV平均增加10.83 ± 2.59 cm/s,ICA/CCA比值平均增加0.18 ± 0.05(均P < .01)。
  • 4例已知60%–69%狭窄患者ICA和CCA EDV的增加幅度(分别为75.8和13.3 cm/s)显著大于<50%或无狭窄患者。
  • 离心泵LVAD较轴流泵LVAD的ICA EDV增加更显著(26.0 vs 6.3 cm/s;P < .01)。
  • 颈动脉侧别对平均流速差异无显著影响。

关键数值与推荐

  • LVAD植入前7条颈动脉(13%)狭窄>50%,53条(87%)狭窄0%–50%。
  • LVAD植入后ICA PSV变化P = .167,其余平均流速变化均P < .01。
  • 离心泵与轴流泵LVAD的ICA EDV增加比较P < .01。

临床怎么用

  • 对LVAD患者解读颈动脉双功超声流速时需谨慎,现有标准可能高估或低估狭窄程度。
  • LVAD类型(离心泵 vs 轴流泵)可能影响EDV测量,解读时应考虑。
  • 狭窄<50%者流速变化小,可能无需过度解读。

局限性

  • 回顾性研究,样本量较小(36例患者,61条ICA)。
  • 未报告常规血管造影对照验证狭窄程度。
  • 两次CDUS检查间隔平均647天,期间流速可能受其他因素影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Although conventional angiography remains the reference standard for the grading of carotid stenosis, carotid duplex ultrasound (CDUS) is the most commonly used modality for determining the degree of carotid stenosis. The validity of CDUS findings for patients after left ventricular assist device (LVAD) implantation is questionable, because the velocities are often altered secondary to the continuous flow nature of the devices. METHODS: A retrospective review was performed of all patients who had undergone LVAD implantation from January 2007 to December 2019. All patients who had undergone CDUS before and after LVAD implantation were included. Patients receiving extracorporeal membrane oxygenation, those with unusable carotid imaging studies, and those with internal carotid artery (ICA) occlusion were excluded. The peak systolic velocity (PSV) and end-diastolic velocity (EDV) in the ICA and common carotid artery (CCA) and the ICA/CCA ratios were compared before and after LVAD implantation. RESULTS: A total of 36 patients (mean age 59 years; 30 men; 6 women) had undergone CDUS both before and after LVAD implantation (mean, 647 days between imaging studies). A total of 61 ICAs had met the criteria for inclusion. Before LVAD, 7 carotid arteries (13%) had had >50% carotid stenosis and 53 (87%) had had 0% to 50% stenosis. The mean changes in the velocities after LVAD were as follows. The ICA PSV had decreased by 6.12 ± 4.34 cm/s, and the ICA EDV had increased by 13.44 ± 4.23 cm/s. The CCA PSV had decreased by 17.22 ± 4.95 cm/s, and the CCA EDV had increased by 10.83 ± 2.59 cm/s. The mean ICA/CCA ratio had increased by 0.18 ± 0.05. All the mean changes in velocity were significant (P < .01), except for the ICA PSV (P = .167). Among four patients with known stenosis of 60% to 69%, the degree of increase in the ICA and CCA EDVs (75.8 and 13.3 cm/s, respectively) was significantly greater than that for patients with <50% or no stenosis. Carotid artery laterality did not significantly affect the differences in mean velocity. Centrifugal LVADs resulted in a significantly larger increase in the ICA EDV compared with axial LVADs (26.0 vs 6.3 cm/s; P < .01). CONCLUSIONS: LVADs were associated with significant changes in CCA PSV, ICA and CCA EDV, and ICA/CCA ratios. However, the magnitude of these changes in patients with <50% stenosis was minimal and might not be clinically significant. The LVAD type might only have an effect on EDV measurements in the CCA, and the left and right carotid arteries did not appear to have different degrees of change in velocity. The currently used criteria for determining carotid stenosis might result in an under- or overestimation of carotid stenosis in patients with an LVAD.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Kronfli A, Atnip RG, Aziz F, et al. Carotid artery duplex velocity criteria might be equivocal after left ventricular assist device implantation. J Vasc Surg. 2021. PMID: 33957226. doi:10.1016/j.jvs.2021.03.062

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。