文献速递主动脉疾病

胸主动脉腔内修复对Stanford B型夹层真腔螺旋形态的影响

Influence of thoracic endovascular aortic repair on true lumen helical morphology for Stanford type B dissections.
PubMed 文献 · J Vasc Surg · 2021-04-30

结果显示TEVAR后螺旋角及平均/峰值螺旋扭转未变,但螺旋半径及偏心度减小、横截面积及周长增加,提示真腔螺旋形态变直且管腔更圆、扩大。

要点

  • TEVAR后真腔螺旋角及螺旋扭转保持不变,提示支架在角度方向顺应螺旋形态。
  • TEVAR后真腔螺旋半径及偏心度减小,横截面积及周长增加。
  • 急性期夹层真腔周长在TEVAR后增加,慢性期未见增加。

核心结论

  • TEVAR后真腔螺旋角及螺旋扭转不变,螺旋半径减小提示螺旋形态变直,管腔更圆且扩大,理论上可降低支架段血流阻力。

主要发现

  • TEVAR后手性与非手性原生夹层的双峰分布消失;亚组分析显示急性夹层真腔周长增加,慢性夹层未见增加。

临床怎么用

  • TEVAR可改变B型夹层真腔螺旋形态,使其更直、更圆且扩大,可能降低局部血流阻力。
  • 支架与主动脉组织的相互作用可为器械设计、植入技术及长期预后改善提供参考。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) can change the morphology of the flow lumen in aortic dissections, which may affect aortic hemodynamics and function. This study characterizes how the helical morphology of the true lumen in type B aortic dissections is altered by TEVAR. METHODS: Patients with type B aortic dissection who underwent computed tomography angiography before and after TEVAR were retrospectively reviewed. Images were used to construct three-dimensional stereolithographic surface models of the true lumen and whole aorta using custom software. Stereolithographic models were segmented and co-registered to determine helical morphology of the true lumen with respect to the whole aorta. The true lumen region covered by the endograft was defined based on fiducial markers before and after TEVAR. The helical angle, average helical twist, peak helical twist, and cross-sectional eccentricity, area, and circumference were quantified in this region for pre- and post-TEVAR geometries. RESULTS: Sixteen patients (61.3 ± 8.0 years; 12.5% female) were treated successfully for type B dissection (5 acute and 11 chronic) with TEVAR and scans before and after TEVAR were retrospectively obtained (follow-up interval 52 ± 91 days). From before to after TEVAR, the true lumen helical angle (-70.0 ± 71.1 to -64.9 ± 75.4°; P = .782), average helical twist (-4.1 ± 4.0 to -3.7 ± 3.8°/cm; P = .674), and peak helical twist (-13.2 ± 15.2 to -15.4 ± 14.2°/cm; P = .629) did not change. However, the true lumen helical radius (1.4 ± 0.5 to 1.0 ± 0.6 cm; P < .05) and eccentricity (0.9 ± 0.1 to 0.7 ± 0.1; P < .05) decreased, and the cross-sectional area (3.0 ± 1.1 to 5.0 ± 2.0 cm2; P < .05) and circumference (7.1 ± 1.0 to 8.0 ± 1.4 cm; P < .05) increased significantly from before to after TEVAR. The distinct bimodal distribution of chiral and achiral native dissections disappeared after TEVAR, and subgroup analyses showed that the true lumen circumference of acute dissections increased with TEVAR, although it did not for chronic dissections. CONCLUSIONS: The unchanged helical angle and average and peak helical twists as a result of TEVAR suggest that the angular positions of the true lumen are constrained and that the endografts were helically conformable in the angular direction. The decrease of helical radius indicated a straightening of the corkscrew shape of the true lumen, and in combination with more circular and expanded lumen cross-sections, TEVAR produced luminal morphology that theoretically allows for lower flow resistance through the endografted portion. The impact of TEVAR on dissection flow lumen morphology and the interaction between endografts and aortic tissue can provide insight for improving device design, implantation technique, and long-term clinical outcomes.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Bondesson J, Suh GY, Marks N, et al. Influence of thoracic endovascular aortic repair on true lumen helical morphology for Stanford type B dissections. J Vasc Surg. 2021. PMID: 33940073. doi:10.1016/j.jvs.2021.04.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。