文献速递主动脉疾病

小腹主动脉瘤监测2年内EVAR解剖适合性保持稳定

Anatomic eligibility for endovascular aneurysm repair preserved over 2 years of surveillance.
PubMed 文献 · J Vasc Surg · 2021-05-04

本研究基于N-TA3CT临床试验中192例小腹主动脉瘤患者,比较基线与2年随访时基于7种现行腔内装置说明书判定的EVAR解剖适合性。结果显示基线与2年适合率均为85%(P=1.00),基线适合者中98%在2年后仍适合,颈长不足是主要不适合原因。

要点

  • 小AAA监测2年内EVAR解剖适合性保持稳定,适合率均为85%。
  • 基线适合EVAR者中98%在2年后仍适合。
  • 颈长不足是基线和随访中失去适合性的最常见原因。

核心结论

  • 进入小AAA监测程序时适合EVAR的大多数患者在2年后仍适合。
  • AAA颈解剖发生实质性变化导致失去EVAR选项的情况不常见。
  • 解剖进展超出EVAR适合性的患者仍可考虑复杂EVAR或开放修复。

研究设计与样本

  • 基于N-TA3CT临床试验(NCT01756833)的队列分析,纳入完成基线和2年随访CT的192例患者(168男、24女)。
  • 女性基线AAA最大横径3.5–4.5 cm,男性3.5–5.0 cm。
  • 在集中影像核心实验室工作站测量近端瘤颈直径、AAA长度和肾下颈角。
  • 以7种研究装置说明书中至少一种的适应证判定EVAR适合性。
  • 采用配对t检验比较2年主动脉测量差异,McNemar检验比较2年适合性。

主要发现

  • 基线和2年EVAR适合率均为85%(P=1.00;95%CI -0.034至0.034)。
  • 基线164例EVAR适合者中,160例(98%)在2年监测期间仍适合。
  • 基线不适合的28例中18例因颈长不足,2年内失去适合性的4例中3例因颈长不足。

关键数值与推荐

  • EVAR适合性判定依据近端主动脉颈直径、AAA长度和肾下颈角,符合7种研究装置中至少一种的说明书要求。
  • 女性基线AAA最大横径3.5–4.5 cm,男性3.5–5.0 cm。

临床怎么用

  • 小AAA监测期间可向患者说明2年内EVAR解剖适合性大概率保持不变。
  • 颈长不足是失去EVAR适合性的主要原因,监测中应关注瘤颈形态变化。
  • 若解剖进展超出标准EVAR适合性,可评估复杂EVAR或开放修复。

局限性

  • 仅纳入完成基线和2年CT随访的患者,可能存在选择偏倚。
  • 适合性基于7种研究装置的说明书判定,未反映其他装置或最新进展。
  • 随访时间仅2年,长期解剖变化未评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Endovascular aneurysm repair (EVAR) is a widely used option for patients with suitable vascular anatomy who have a large infrarenal abdominal aortic aneurysm (AAA). Patients with small AAAs are managed with careful surveillance and it is a common concern that their anatomy may change with AAA growth, and their option for EVAR may become limited. Device innovation has resulted in expanded ranges of anatomy that may be eligible for EVAR. This study sought to identify changes in anatomic eligibility for repair with contemporary endovascular devices in AAA patients, monitored by computed tomography scan over the course of 2 years. METHODS: Patients from the Non-Invasive Treatment of Abdominal Aortic Aneurysm Clinical Trial (N-TA3CT, NCT01756833) were included in this analysis. Females had baseline AAA maximum transverse diameter between 3.5 and 4.5 cm, and males had baseline maximum transverse diameter between 3.5 and 5.0 cm. Patients were included in this analysis if they completed pre-enrollment and 2-year follow-up computed tomography imaging. Pertinent anatomic measurements were performed on a postprocessing workstation in a centralized imaging core laboratory. EVAR candidacy was determined by measuring proximal aortic neck diameter, AAA length, and infrarenal neck angulation. Patients were considered to be eligible for EVAR if they qualified for at least one of the seven studied devices' instructions for use at baseline and at 2 years. A paired t test analysis was used to detect differences in aortic measurements over 2 years, and the McNemar test was used to compare eligibility over 2 years. RESULTS: We included 192 patients in this analysis-168 male and 24 female. Of these patients, 85% were eligible for EVAR at baseline and 85% after 2 years of follow-up (P = 1.00; 95% confidence interval -0.034 to 0.034). Of the 164 EVAR candidates at baseline, 160 (98%) remained eligible over 2 years of surveillance. Insufficient neck length was the most common reason for both ineligibility at baseline (18 of 28 patients) as well as loss of candidacy over 2 years (3 of 4 patients). CONCLUSIONS: The majority of patients eligible for EVAR when entering a surveillance program for small AAA remain eligible after 2 years. Substantial changes in AAA neck anatomy resulting in loss of EVAR treatment options are infrequent. Patients with anatomic AAA progression beyond EVAR eligibility remain candidates for complex EVAR and open repair.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Panthofer AM, Olson SL, Rademacher BL, et al. Anatomic eligibility for endovascular aneurysm repair preserved over 2 years of surveillance. J Vasc Surg. 2021. PMID: 33957227. doi:10.1016/j.jvs.2021.04.044

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。