二维灌注血管造影在慢性肢体威胁性缺血患者中的重复性及观察者内与观察者间一致性

Repeatability, and Intra-Observer and Interobserver Agreement of Two Dimensional Perfusion Angiography in Patients with Chronic Limb Threatening Ischaemia.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2021-03-18

本研究前瞻性纳入20例慢性肢体威胁性缺血(CLTI)患者,在膝下血管内血运重建术前以5分钟间隔进行两次二维灌注血管造影,评估重复性及观察者内与观察者间一致性。

要点

  • 观察者内与观察者间一致性均极佳,各参数组内相关系数为1.00。
  • 需按本研究标准化方法操作,结果方可视为可靠。

核心结论

  • 二维灌注血管造影在CLTI患者中的重复性及观察者内与观察者间一致性均为优秀,按标准化方法使用是可靠工具。

研究设计与样本

  • 前瞻性临床研究,纳入20例CLTI并接受膝下血管内血运重建的患者,术前以5分钟间隔采集两次灌注造影。
  • 观察者内一致性由1名观察者对每例同一采集行5次测量评估,观察者间一致性由3名观察者对每例同一采集行测量评估。

主要发现

  • 20例患者的观察者内与观察者间一致性在所有参数上均为1.00。

关键数值与推荐

  • 观察者内与观察者间一致性:20例,所有参数组内相关系数1.00。

临床怎么用

  • 在CLTI患者中可按照本研究描述的标准化方法使用二维灌注血管造影获取定量足部灌注信息。
  • 测量结果在不同观察者及同一观察者多次测量间稳定,可作为可靠的灌注评估工具。

局限性

  • 重复性分析中2例因严重运动伪影被排除,可能影响该方法在运动伪影患者中的适用性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Two dimensional (2D) perfusion angiography is a method that provides quantitative foot perfusion information from standard digital subtraction angiography acquisitions. The aim of this study was to test the reliability of this method in patients with chronic limb threatening ischaemia (CLTI) by investigating repeatability, and intra-observer and interobserver agreement. METHODS: Twenty patients with CLTI and a below the knee endovascular revascularisation were included in a prospective clinical study. Prior to treatment two perfusion angiography runs were acquired with a five minute interval without performing an intervention. In these recordings, regions of interest were selected and time density curves and perfusion parameters were determined. To investigate intra-observer agreement one observer performed five measurements on the same acquisition for each patient. To investigate interobserver agreement three observers performed measurements on the same acquisition for each patient. Results were presented in Bland-Altman plots and as the intraclass correlation coefficient per parameter. RESULTS: Two patients were excluded from repeatability analyses because of major motion artefacts. Repeatability analyses of the 18 remaining patients showed excellent correlation for every parameter (> .96). Intra-observer and interobserver agreement for all 20 patients were excellent for all parameters (1.00). CONCLUSION: Repeatability and intra-observer and interobserver agreement of 2D perfusion angiography in patients with CLTI were found to be excellent. It is therefore a reliable tool when used according to the standardised methods described in this study.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Ipema J, Heinen SGH, Janssens AJB, et al. Repeatability, and Intra-Observer and Interobserver Agreement of Two Dimensional Perfusion Angiography in Patients with Chronic Limb Threatening Ischaemia. Eur J Vasc Endovasc Surg. 2021. PMID: 33744094. doi:10.1016/j.ejvs.2021.02.014