PubMed 文献 · J Vasc Surg · 2021-03-05

本研究为多中心临床研究,纳入182例EVAR术后患者,比较3D-US AAA模型、CTA和2D-US测量瘤囊前后径的准确性。Bland-Altman分析显示3D-US与CTA平均差异为-2.43 mm(95%CI -5.20至0.14;P=.07),无统计学差异;而2D-US与CTA差异为-3.62 mm(95%CI -6.14至-1.10;P=.002)。结论认为3D-US AAA模型软件是EVAR术后监测前后径的可行方法。

要点

  • 3D-US与CTA测瘤囊前后径无显著差异,偏倚小于2D-US。
  • 3D-US可作为EVAR术后监测的可行替代模态。
  • 2D-US与CTA差异有统计学意义,提示其偏倚较大。

核心结论

  • 3D-US AAA模型测量前后径与CTA无显著差异,偏倚小于2D-US,是EVAR术后监测的可行模态。

研究设计与样本

  • 所有图像本地采集,2D-US和CTA同时本地和中心判读,3D-US仅中心判读,图像匿名随机盲法判读。
  • 用于评估3D-US和2D-US准确性的样本分别包含164例和177例患者。

主要发现

  • CTA与3D-US平均差异为-2.43 mm(95%CI -5.20至0.14;P=.07),一致性界限下限-8.9 mm(95%CI -9.3至-8.4),上限2.7 mm(95%CI 2.3-3.2)。
  • 2D-US与CTA平均差异为-3.62 mm(95%CI -6.14至-1.10;P=.002),一致性界限下限-10.3 mm(95%CI -10.8至-9.8),上限2.5 mm(95%CI 2-2.9)。

临床怎么用

  • EVAR术后监测中可采用3D-US AAA模型软件测量瘤囊前后径,作为CTA的替代或补充手段。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Three-dimensional ultrasound (3D-US) has already demonstrated improved reproducibility with a high degree of agreement (intermodality variability), reproducibility (interoperator variability), and repeatability (intraoperator variability) compared with conventional two-dimensional ultrasound (2D-US) when estimating the maximum diameter of native abdominal aortic aneurysms (AAAs). The aim of the present study was, in a clinical, multicenter setting, to evaluate the accuracy of 3D-US with aneurysm model quantification software (3D-US abdominal aortic aneurysm [AAA] model) for endovascular aortic aneurysm repair (EVAR) sac diameter assessment vs that of computed tomography angiography (CTA) and 2D-US. METHODS: A total of 182 patients who had undergone EVAR from April 2016 to December 2017 and were compliant with a standardized EVAR surveillance program were enrolled from five different vascular centers (Rigshospitalet, Copenhagen, Denmark; Catharina Ziekenhuis, Eindhoven, Netherlands; L'hospital de la Timone, Paris, France; Cleveland Clinic, Cleveland, Ohio; and The Christ Hospital, Cincinnati, Ohio) in four countries. All image acquisitions were performed at the local sites (ie, 2D-US, 3D-US, CTA). Only the 2D-US and CTA readings were performed both locally and centrally. All images were read centrally by the US and CTA core laboratory. Anonymized image data were read in a randomized and blinded manner. RESULTS: The sample used to estimate the accuracy of the 3D-US AAA model and 2D-US included 164 patients and 177 patients, respectively. The Bland-Altman analysis revealed that the mean difference between CTA and 3D-US was -2.43 mm (95% confidence interval [CI], -5.20 to 0.14; P = .07) with a lower and upper limit of agreement of -8.9 mm (95% CI, -9.3 to -8.4) and 2.7 mm (95% CI, 2.3-3.2), respectively. For 2D-US and CTA, the mean difference was -3.62 mm (95% CI, -6.14 to -1.10; P = .002), with a lower and upper limit of agreement of -10.3 mm (95% CI, -10.8 to -9.8) and 2.5 mm (95% CI, 2-2.9), respectively. CONCLUSIONS: The 3D-US AAA model showed no significant difference compared with CTA for measuring the anteroposterior diameter, indicating less bias for 3D-US compared with 2D-US. Thus, 3D-US with AAA model software is a viable modality for anteroposterior diameter assessment for surveillance after EVAR.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Ghulam Q, Bredahl K, Eiberg J, et al. Three-dimensional ultrasound is a reliable alternative in endovascular aortic repair surveillance. J Vasc Surg. 2021. PMID: 33684470. doi:10.1016/j.jvs.2021.02.031

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。