开放胸腹主动脉瘤修复术后纤维蛋白原补充的触发与目标值:ROTEM研究
单中心回顾性观察研究纳入166例择期开放胸腹主动脉瘤修复患者,术后ICU入住时A10 FIBTEM与24小时引流量呈负线性关系,A10 FIBTEM≤3mm独立关联术后严重出血,A10 FIBTEM预测严重出血的AUC为0.63,最佳截断值9mm。
要点
- ICU入住时A10 FIBTEM≤3mm与开放TAAA修复术后严重出血独立相关。
- A10 FIBTEM预测严重出血的AUC为0.63,最佳截断值9mm。
- A10 FIBTEM 3mm的阳性预测值为50%,9mm的阴性预测值为92%。
核心结论
- 开放TAAA修复患者ICU入住时A10 FIBTEM≤3mm与术后严重出血独立相关。
- 基于A10 FIBTEM的纤维蛋白原补充触发值和目标值已提供,但需进一步验证。
研究设计与样本
- 单中心回顾性观察研究,纳入2016年3月至2019年1月166例择期开放TAAA修复患者。
- 排除急诊、先天性或获得性凝血病、术前5天内使用P2Y12抑制剂者。
- 所有患者按旋转血栓弹力图驱动的输血方案进行术中及术后管理。
主要发现
- A10 FIBTEM 3mm的阳性预测值为50%,9mm的阴性预测值为92%。
- 多变量分析中,A10 FIBTEM≤3mm仍独立关联严重出血。
关键数值与推荐
- A10 FIBTEM≤3mm为严重出血的独立关联阈值。
- A10 FIBTEM 9mm为预测严重出血的最佳截断值,阴性预测值92%。
- A10 FIBTEM 3mm对应阳性预测值50%。
临床怎么用
- 开放TAAA修复术后可依据ICU入住时A10 FIBTEM评估严重出血风险。
- A10 FIBTEM≤3mm提示需考虑纤维蛋白原补充,9mm可作为目标参考值。
- 截断值的可转移性和可靠性需进一步研究验证。
局限性
- 单中心回顾性观察研究设计。
- 截断值的可转移性和可靠性需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To determine the relationship between the value of fibrinogen assessed by the FIBTEM clot amplitude at 10 minutes (A10 FIBTEM) measured on admission to the intensive care unit (ICU) and the amount of drainage output at 24 hours, to investigate whether the A10 FIBTEM predicts severe bleeding (SB), and to define A10 FIBTEM thresholds to prevent (trigger) and treat (target) severe bleeding by fibrinogen supplementation. METHODS: In a single centre, retrospective observational study, 166 patients underwent elective open thoraco-abdominal aortic aneurysm (TAAA) repair between March 2016 and January 2019. Exclusion criteria were emergency, congenital, or acquired coagulopathy, or administration of P2Y12 inhibitor antiplatelet agents in the five days before surgery. All patients were managed intra-operatively and post-operatively according to a rotational thromboelastometry driven transfusion protocol. The principal endpoint was a composite outcome, which included bleeding, large volume transfusion, and re-operation. RESULTS: FIBTEM clot amplitude after 10 minutes measured on ICU admission and post-operative bleeding at 24 hours showed an inverse linear relationship (R2 = .03; p = .026). Performance of A10 FIBTEM in predicting SB evaluated by Receiving Operating Curve analysis showed an area under the curve of 0.63 (95% CI 0.56 - 0.70; p = .026) with a best cutoff of 9 mm. An A10 FIBTEM of 3 mm was the cutoff associated with a positive predictive value of 50%, while an A10 FIBTEM of 9 mm showed a negative predictive value of 92%. On multivariable analysis, an A10 FIBTEM ≤ 3 mm remained independently associated with SB. CONCLUSION: The present investigation shows for the first time in a population undergoing open TAAA repair that an A10 FIBTEM ≤ 3mm on ICU admission is associated with post-operative severe bleeding. Trigger and target values for fibrinogen supplementation, based on A10 FIBTEM, have been provided. The transferability and reliability of these cutoff values require further study.
引用
- Monaco F, Barucco G, Licheri M, et al. Trigger and Target for Fibrinogen Supplementation Using Thromboelastometry (ROTEM) in Patients Undergoing Open Thoraco-Abdominal Aortic Aneurysm Repair. Eur J Vasc Endovasc Surg. 2021. PMID: 33773905. doi:10.1016/j.ejvs.2021.02.046
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。