文献速递慢性静脉疾病

经腹超声与血管内超声测量髂总静脉狭窄显著相关

Transabdominal duplex ultrasound and intravascular ultrasound planimetry measures of common iliac vein stenosis are significantly correlated in a symptomatic population.
PubMed 文献 · J Vasc Surg Venous Lymphat Disord · 2021-02-04

本研究在有慢性静脉功能不全症状且高度怀疑髂静脉梗阻的患者中,比较经腹双功能超声(TAUS)与血管内超声(IVUS)面积测量法对左侧髂总静脉(CIV)狭窄的检测效度。47例患者数据显示,两种方法对≥50%狭窄的识别一致率为89%,TAUS阳性预测值为95.5%,TAUS最小直径与IVUS最小面积及狭窄百分比显著相关。

要点

  • TAUS与IVUS对左侧CIV≥50%狭窄的识别一致率达89%。
  • TAUS阳性预测值为95.5%,支持其作为无创筛查工具。
  • TAUS直径≤8 mm对应IVUS面积狭窄≥50%,可触发IVUS检查。

核心结论

  • TAUS可作为检测髂静脉梗阻的有效诊断工具。
  • TAUS测量的CIV直径≤8 mm可作为临床相关狭窄的阈值,提示需行IVUS检查。

研究设计与样本

  • 回顾性分析私人血管实验室中因慢性静脉功能不全症状且高度怀疑IVO而拟行IVUS治疗的患者数据。
  • 共纳入47例患者(83%女性,年龄49.3±17.3岁,64%肥胖),均曾行TAUS和IVUS检查。

主要发现

  • TAUS与IVUS对左侧CIV≥50%狭窄的识别一致率为89%。
  • TAUS的阳性预测值为95.5%。
  • TAUS最小直径和狭窄百分比与IVUS最小直径、最小面积及面积狭窄百分比显著相关。
  • TAUS最小直径与IVUS最小面积及面积狭窄百分比相关性最强。

关键数值与推荐

  • TAUS静脉直径8 mm对应IVUS横截面积94.2 mm²(狭窄53%)。
  • IVUS横截面积狭窄50%对应TAUS直径8.56 mm。

临床怎么用

  • TAUS可用于髂静脉梗阻的无创评估,TAUS直径≤8 mm提示临床相关狭窄,应触发IVUS检查。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The objectives of the present study were to determine the validity of transabdominal duplex ultrasound (TAUS) against the reference standard of intravascular ultrasound (IVUS) examinations for the detection of iliac vein obstruction (IVO). METHODS: We analyzed the data from patients at a private vascular laboratory who had undergone IVUS investigation with an intention to treat because of symptoms of chronic venous insufficiency and a high suspicion of IVO. These patients had also previously undergone a TAUS examination at the same location. The TAUS and IVUS planimetry measures of the left common iliac vein (CIV) were correlated. These included the TAUS-measured minimum and maximum diameter and the percentage of stenosis with the IVUS-measured minimum and maximum diameter and area and the percentage of stenosis. RESULTS: The TAUS and IVUS data from 47 patients (83% female; age, 49.3 ± 17.3 years; 64% obese) were included in the analyses. We found 89% agreement between the TAUS and IVUS findings regarding the identification of left CIV stenosis of ≥50%. The TAUS data had a positive predictive value of 95.5%. The TAUS measures of the minimum diameter and percentage of stenosis correlated significantly with the IVUS measures of the minimum diameter, minimum area, and cross-sectional area of the percentage of stenosis. The strongest correlations were between the TAUS-measured minimum diameter and IVUS-measured minimum area and percentage of the area of stenosis according to the literature-derived value. The TAUS-measured vein diameter of 8 mm equated to an IVUS cross-sectional area of 94.2 mm2 (53% stenosis), and an IVUS cross-sectional area of 50% of stenosis equated to a TAUS diameter of 8.56 mm. CONCLUSIONS: The findings from the present study support the validity of TAUS evaluation as a workup diagnostic tool for the detection of IVO. Our findings also support the use of TAUS planimetry-in particular, the CIV diameter of ≤8 mm as a threshold value-to indicate clinically relevant stenosis and trigger an IVUS investigation with an intention to treat, because this correlated with a cross-sectional area stenosis of ≥50%, as determined by IVUS examination.

来源:J Vasc Surg Venous Lymphat Disord,查看原文。版权归原作者所有。

引用

  1. Villalba L, Larkin TA. Transabdominal duplex ultrasound and intravascular ultrasound planimetry measures of common iliac vein stenosis are significantly correlated in a symptomatic population. J Vasc Surg Venous Lymphat Disord. 2021. PMID: 33548556. doi:10.1016/j.jvsv.2021.01.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。