球囊辅助真腔扩张与开窗技术预处理主动脉夹层后三腔胸腹动脉瘤以辅助t-Branch腔内修复
本文报告一例43岁男性症状性慢性夹层后9 cm胸腹主动脉瘤,伴三腔(1真腔2假腔)及真腔塌陷。采用32 mm Coda球囊扩张真腔,并用12 mm非顺应性球囊和32 mm Coda球囊多处穿刺扩张内膜片建立再入口,形成单一主动脉腔后,成功植入胸主动脉支架及t-Branch多分支支架。患者顺利出院,3个月随访CT血管造影示靶血管通畅,仅少量IIb型内漏。
要点
- 球囊辅助真腔扩张与内膜片开窗可预处理塌陷真腔,为多分支支架植入创造条件。
- 该技术用于复杂夹层后胸腹主动脉瘤的腔内修复,术后靶血管通畅。
- 随访仅见少量IIb型内漏,短期结果满意。
核心结论
- 采用球囊辅助真腔扩张与内膜片开窗预处理主动脉,是治疗伴真腔塌陷的复杂夹层后胸腹主动脉瘤可行且安全的方法。
研究设计与样本
- 个案报告:1例43岁男性症状性慢性夹层后9 cm胸腹主动脉瘤,伴三腔形成及远端胸主动脉水平真腔塌陷。
主要发现
- 腹腔干和右肾动脉由真腔供血,左肾动脉由假腔供血,肠系膜上动脉由真假腔共同供血。
- 使用32 mm Coda球囊扩张真腔,并用12 mm非顺应性球囊和32 mm Coda球囊多处穿刺扩张内膜片建立再入口,形成单一主动脉腔。
- 随后植入胸主动脉支架和t-Branch多分支支架,患者顺利出院。
- 3个月随访CT血管造影示靶血管通畅,仅见少量IIb型内漏。
关键数值与推荐
- 真腔扩张使用32 mm Coda球囊(COOK Medical)。
- 内膜片穿刺后先用12 mm非顺应性球囊扩张,再用32 mm Coda球囊扩张。
临床怎么用
- 对于伴真腔塌陷的复杂夹层后胸腹主动脉瘤,可考虑球囊辅助真腔扩张与开窗预处理,以辅助多分支支架腔内修复。
局限性
- 个案报告,结果外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To present the challenging endovascular treatment of a symptomatic triple-barrel (3 lumens; 1 true and 2 false lumens) aortic dissection case. METHODS: A 43-year-old male was introduced with a symptomatic, 9 cm postchronic dissection thoracoabdominal aortic aneurysm with accompanying triple-barrel formation and true lumen collapse at the height of the distal thoracic aorta. The celiac axis and right renal artery were perfused from the true lumen, the left renal artery from the false lumen and the superior mesenteric artery from both lumens. Endovascular approach was decided due to the patient co-morbidities. Because of the collapsed true lumen, the aorta had to be preconditioned in order to facilitate the endovascular repair with a multibranched thoracoabdominal stent-graft. This was achieved through the dilation of the aortic true lumen with a 32 mm Coda balloon (COOK Medical, Bloomington, IN), then puncturing of the intimal flap in several places to create re-entries that were also dilated (first with a 12-mm noncompliant balloon and then with a compliant 32 mm Coda balloon), creating a single aortic lumen that could facilitate an endovascular repair with thoracic stent-grafts and an off-the-shelf multibranched endograft (t-Branch; COOK Medical). The patient was promptly discharged, and the 3-month follow-up CT-angiogram showed a satisfactory result with patent target vessels and only a small Type-IIb endoleak. CONCLUSIONS: Preconditioning of the aorta using this technique is a feasible and safe approach for the treatment of complex thoracoabdominal postdissection aortic aneurysms presenting with a true lumen collapse.
引用
- Konstantinou N, Banafsche R, Mehmedovic A, et al. Balloon-Assisted True Lumen Expansion and Fenestration of a Symptomatic, Triple-Barrel, Postdissection Thoracoabdominal Aneurysm with Collapsed True Lumen to Facilitate Endovascular Treatment with a t-Branch. Ann Vasc Surg. 2021. PMID: 33556515. doi:10.1016/j.avsg.2021.01.085
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。